GB/T 35800-2018Determination of hexamidine, chlorhexidine and their salts as preservatives in cosmetics—High performance liquid chromatography (English PDF)
化妆品中防腐剂己脒定和氯己定及其盐类的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35800-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35800-2018 is the English-translated version of 化妆品中防腐剂己脒定和氯己定及其盐类的测定 高效液相色谱法.
GB/T 35800-2018 gives a high performance liquid chromatography method for determining hexamidine, chlorhexidine and their salts used as preservatives in cosmetics.
It applies to aqueous, creamy, shampoo, powdered and lipstick products. Samples are extracted with solvent, centrifuged and passed through a microporous membrane, then quantified by the external standard method and confirmed by liquid chromatography-mass spectrometry.
The standard lists the reagents, instruments and sample preparation, the reference chromatographic conditions and the result calculation, with a detection limit of 0.002% and a quantitation limit of 0.004%.
Recovery lies between 84.1% and 99.7% over 0.004% to 0.3%, and two independent results may not differ by more than 10% of their mean. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35800-2018
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Principle4
- 4 Reagents and Materials4
- 5 Instruments and Equipment5
- 6 Steps of Determination6
- 7 Result Calculation8
- 8 Detection Limit and Quantitation Limit8
- 9 Recovery Rate and Precision8
- 10 Allowable Difference8
- Appendix A (Informative) Basic Information of Hexamidine Diisethionate (isethionate) and Chlorhexidine Standards9
- Appendix B (Informative) Liquid Chromatogram of Hexamidine and Chlorhexidine10
- Appendix C (Informative) Confirmation Test11
1 Scope
This Standard specifies the method of high performance liquid chromatography of determining hexamidine, chlorhexidine and their salts as preservatives in cosmetics.
This Standard is applicable to the determination of hexamidine, chlorhexidine and their salts as preservatives in aqueous, creamy, shampoo, powdered and lipstick cosmetics.
The detection limit and the limit of quantitation of this Standard. the detection limit of hexamidine, chlorhexidine and their salts. 0.002%; the limit of quantitation. 0.004%.
2 Normative References
The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. The latest version (including all the modifications) of references without a specified date is applicable to this Standard.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
3 Principle
Sample shall receive solvent extraction, centrifugation and microporous membrane filtration, then, be determined through high performance liquid chromatography; it shall be quantified through external standard method and confirmed through liquid chromatography-mass spectrometry.
4 Reagents and Materials
Unless it is otherwise stipulated, all reagents shall be analytical purity. Water shall be Grade-1 water that is stipulated in GB/T 6682.
4.1 Acetonitrile. chromatographic purity.
4.2 Methanol. chromatographic purity.
4.3 Tetrahydrofuran.
6 Steps of Determination
6.1 Sample Processing
6.1.1 Aqueous, creamy, shampoo and powdered sample
Weigh-take 0.5 g (accurate to 0.001 g) of sample, place it into a 50 mL PTFE centrifuge tube with a plug (5.7); add 1 mL of saturated sodium chloride solution (4.6), then, start vortex mixing. Add 9 mL of water; after vortex mixing, start centrifugation at 5,000 r/min for 10 min. Transfer the supernatant into another 50 mL PTFE centrifuge tube with a plug. In the sample residue, continue to add 10 mL of methanol (4.2); in ultrasonic water bath (5.3), start ultrasonic extraction for 20 min. Start centrifugation at 5,000 r/min for 10 min; combine the supernatant, then, filter it through 0.45 µm microporous membrane (5.8) for the determination with high performance liquid chromatography.
6.1.2 Creamy sample
Weigh-take 0.5 g (accurate to 0.001 g) of sample, place it into a 50 mL PTFE centrifuge tube with a plug (5.7); add 2 mL of tetrahydrofuran (4.3), start vortex mixing. Add 8 mL of water; after vortex mixing, start centrifugation at 5,000 r/min for 10 min. Transfer the supernatant into another 50 mL PTFE centrifuge tube with a plug. In the sample residue, continue to add 10 mL of methanol (4.2); in ultrasonic water bath (5.3), start ultrasonic extraction for 20 min. Start centrifugation at 5,000 r/min for 10 min; combine the supernatant, then, filter it through 0.45 µm microporous membrane (5.8) for the determination with high performance liquid chromatography.
6.2 Conditions of Determination
The determination with high performance liquid chromatography shall be based on the following reference conditions.
a) Chromatographic column. XTerra MS C18, 5 µm, 250 mm x 4.6 mm (internal diameter), or others with equivalent performance;
b) Mobile phase. please refer to Table 1;
c) Flow rate. 1.0 mL/min;
d) Column temperature. 30 °C;
e) Detection wavelength. 260 nm;
f) Injection volume. 10 µL.
6.5 Blank Test
Follow the above determination conditions and steps, other than the step of weighing-taking sample.
7 Result Calculation
The result shall be calculated in accordance with Formula (1). The calculation result shall retain 2 decimals (the calculation result shall deduct the blank value).
Where,
W---the percentage content of hexamidine, chlorhexidine and their salts in the sample, expressed in %;
c---the concentration of hexamidine and chlorhexidine in the sample, which is obtained through the standard working curve, expressed in (µg/mL);
V---the ultimate constant volume of the sample solution, expressed in (mL);
m---sample mass, expressed in (g).
8 Detection Limit and Quantitation Limit
The detection limit of hexamidine, chlorhexidine and their salts shall be 0.002%; the quantitation limit shall be 0.004%.
9 Recovery Rate and Precision
Within the concentration range of 0.004% ~ 0.3 %, the recovery rate of hexamidine, chlorhexidine and their salts shall be between 84.1% ~ 99.7%, the relative standard deviation shall be 1.1% ~ 7.8%.
10 Allowable Difference
The absolute difference of two independent determination results obtained under repeatability conditions shall not exceed 10% of arithmetic mean value. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35800-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.