GB/T 35799-2018Determination of sodium PCA in cosmetics—High performance liquid chromatography (English PDF)
化妆品中吡咯烷酮羧酸钠的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35799-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35799-2018 is the English-translated version of 化妆品中吡咯烷酮羧酸钠的测定 高效液相色谱法.
GB/T 35799-2018 gives a high performance liquid chromatography method for determining sodium PCA in cosmetics, expressed as pyrrolidone carboxylic acid. It applies to creamy, milky and liquid cosmetics, with a detection limit of 0.003% and a limit of quantitation of 0.01%.
The sample is demulsified with saturated sodium chloride, extracted ultrasonically with the mobile phase, centrifuged and filtered through a 0.45 µm membrane, and the solution is quantified by the external standard method.
The standard lists the reagents, including the potassium dihydrogen phosphate solution at pH 3.0 and the standard stock and working solutions, the instruments, the determination steps, the result calculation, recovery and precision, and the allowable difference. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35799-2018
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Principle4
- 4 Reagents and Materials4
- 5 Instruments and Equipment5
- 6 Steps of Determination5
- 7 Result Calculation7
- 8 Recovery Rate and Precision7
- 9 Allowable Difference7
- Appendix A (Informative) Chinese Name, English Name, INCI Name, CAS No., Molecular Formula, Relative Molecular Mass and Structural Formula of Pyrrolidone Carboxylic Acid8
- Appendix B (Informative) HPLC Chromatogram and DAD Spectrogram of Pyrrolidone Carboxylic Acid Standards9
1 Scope
This Standard specifies the method of high performance liquid chromatography of determining sodium PCA in cosmetics (counted by pyrrolidone carboxylic acid).
This Standard is applicable to the determination of sodium PCA (counted by pyrrolidone carboxylic acid) in creamy, milky and liquid cosmetics.
In terms of sodium PCA (counted by pyrrolidone carboxylic acid), this Standard's detection limit is 0.003%; its limit of quantitation is 0.01%.
2 Normative References
The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. The latest version (including all the modifications) of references without a specified date is applicable to this Standard.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
3 Principle
Sample shall receive demulsification with saturated sodium chloride; mobile phase ultrasonic extraction and centrifugation; filtration with 0.45 µm filter. Inject solution into high performance liquid chromatograph; quantify with external standard method.
4 Reagents and Materials
Unless it is otherwise stipulated, all reagents shall be analytical purity. Water shall be Grade-1 water that is stipulated in GB/T 6682.
4.1 Phosphate. excellent level of purity.
4.2 Sodium chloride.
4.3 Methanol. chromatographic purity.
4.4 Potassium dihydrogen phosphate.
4.5 0.02 mol/L potassium dihydrogen phosphate (pH=3.0). weigh-take 2.72 g of potassium dihydrogen phosphate (4.4); add water to dissolve it; use phosphate (4.1) to adjust pH to 3.0; add water to dilute to the constant volume of 1,000 mL. Use 0.45 µm filter to filter it.
4.6 Saturated sodium chloride. weigh-take 35.2 g of sodium chloride (4.2); add 97.8 g of water; mix it, dissolve it for later usage.
4.7 Pyrrolidone carboxylic acid standards. purity shall be not less than 99.0%. Please refer to Table A.1 in Appendix A for its Chinese name, English name, INCI name, CAS No., molecular formula, relative molecular mass and structural formula.
4.8 Pyrrolidone carboxylic acid standard stock solution. accurately weigh-take 0.1 g of pyrrolidone carboxylic acid standards, accurate to 0.0001 g; place it in a 100 mL volumetric flask, then, use water to dissolve it to the constant volume. Thus, pyrrolidone carboxylic acid standard stock solution (concentration. 1,000 mg/L) can be obtained. Store it in a refrigerator at 4 °C; it shall remain valid within 1 week.
4.9 Standard working solutions. use 0.02 mol/L potassium dihydrogen phosphate (4.5) to separately prepare the above-mentioned standard stock solution (4.8) into a series of standard working solutions at the concentration of 0 mg/L, 2.0 mg/L, 10 mg/L, 50 mg/L, 100 mg/L and 200 mg/L; prepare it right before usage.
5 Instruments and Equipment
5.1 Liquid chromatograph, equipped with UV detector or diode array detector.
5.2 Analytical balance, division value. 0.0001 g.
5.3 Ultrasonic oscillator.
5.4 Centrifuge. rotating speed >= 10,000 r/min.
5.5 Filter membrane. aperture 0.45 µm.
5.6 Centrifuge tube. 10 mL.
5.7 Vortex oscillator.
6 Steps of Determination
6.1 Sample Processing
Weigh-take 0.2 g (accurate to 0.001 g) of sample, place it into a 10 mL centrifuge tube.
Add 1.0 mL of saturated sodium chloride (4.6), then, start vortex shaking for 1 min. Add 5.0 mL of 0.02 mol/L potassium dihydrogen phosphate (4.5). Start ultrasonic extraction […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35799-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 35799-2018
$125.00