Scope
GB/T 35657-2017 is the English-translated version of 化学分析方法验证确认和内部质量控制实施指南 基于样品消解的金属组分分析.
GB/T 35657-2017 is the Chinese standard "Guideline for verification and validation of chemical analysis method and internal quality control-Metal component analysis based on sample digestion".
Its scope clause reads: This standard gives sample-based digestion using atomic absorption spectrometry (AAS), atoms Atomic fluorescence spectrometry (AFS), inductively coupled plasma atomic emission spectrometry (inductively co Pledplasmaatomicemissionspectrometry, ICP-AES, inductively coupled plasma mass spectrometry (inductivelycoupled) Plasmamassspectrometry, ICP-MS) Method for verification of metal components in four testing areas Validation Confirmation and establishment Internal quality of implementation Guidelines for the control system.
This standard applies to atomic absorption spectrometry, atomic fluorescence spectrometry, inductively coupled plasma emission spectrometry, inductively coupled plasmas Methods such as mass spectrometry based on the analysis of metal components in sample digestion confirm the establishment and implementation of an internal quality control system.
This standard deals only with quantitative analysis methods and does not include sampling. For laboratories that use other spectral analysis methods to analyze metal components, refer to the contents of this standard.
Found what you need?
Document preview — GB/T 35657-2017
National Standard of the People's Republic of China
- ICS
- 03.120.10
- Classification
- A 00
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 General
- 5 Method Validation and Validation Technique
- 5.1 Analysis System Adaptability
- 5.2 Selectivity
- 5.3 Stability
- 5.4 Durability
- 5.5 Linearity and Calibration
- 5.6 Recovery rate
- 5.7 Limits of Detection and Limits of Quantification
- 5.8 Detection Capability
- 5.9 Accuracy
- 5.10 Repeatability
- 5.11 Reproducibility
- 5.12 Uncertainty of measurement
- 6 Inspection Process Quality Control
- 6.1 General
- 6.2 Calibration Curve Quality Evaluation and Inspection
- 7 Analysis System Verification
- 7.1 General
- 7.2 Participate in proficiency testing or measurement audit plan
- 7.3 Inter-laboratory comparison
- 7.4 Using Control Chart Verification and Analysis System
- Appendix B (Informative) Example of Inspection Method Stability
- Appendix C (Informative) Durability Test Example
- Appendix D (Informative) Linear and Calibration Confirmation Example
- Appendix E (informative annex) Confirmation of recovery rate
- Appendix F (Informative) Confirmation Limits and Limits of Quantification Confirmation
- Appendix G (Informative) Methodological Test Example Calculation Example
- Appendix H (informative annex) Examples of laboratory bias and precision evaluation
- Appendix I (Informative) Evaluation Examples of Measurement Uncertainty
- Appendix J (Informative) Critical Table of Statistical Analysis
1 Scope
This standard gives sample-based digestion using atomic absorption spectrometry (AAS), atoms
Atomic fluorescence spectrometry (AFS), inductively coupled plasma atomic emission spectrometry (inductively co
Pledplasmaatomicemissionspectrometry, ICP-AES, inductively coupled plasma mass spectrometry (inductivelycoupled)
Plasmamassspectrometry, ICP-MS) Method for verification of metal components in four testing areas Validation Confirmation and establishment Internal quality of implementation
Guidelines for the control system.
This standard applies to atomic absorption spectrometry, atomic fluorescence spectrometry, inductively coupled plasma emission spectrometry, inductively coupled plasmas
Methods such as mass spectrometry based on the analysis of metal components in sample digestion confirm the establishment and implementation of an internal quality control system.
This standard deals only with quantitative analysis methods and does not include sampling.
For laboratories that use other spectral analysis methods to analyze metal components, refer to the contents of this standard.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 3358.1 Statistical terms and symbols - Part 1. General statistical terms and terms used for probabilistic
GB/T 3358.2 Statistical terms and symbols - Part 2. Application statistics
GB/T 3358.3 Statistical terms and symbols - Part 3. Experimental design
GB/T 6379.1 Accuracy (correctness and precision) of measurement methods and results Part 1. General rules and definitions
GB/T 10092-2009 Statistical analysis of data and interpretation of multiple comparisons of test results
GB/T 14666 Analytical Chemistry Terms
GB/T 15000.2 Working Guide for Standard Samples (2) Common Terms and Definitions for Standard Samples
GB/T 15000.3 Working guide for standard samples (2) General principles and statistical methods for setting standard samples
GB 17378.2-2007 Marine Monitoring Code Part 2. Data Processing and Analysis Quality Control
GB/T 19000 Quality Management System Foundation and Terminology
GB/T 22554 Linear Calibration Based on Standard Samples
GB/T 27407 Laboratory Quality Control Utilization Statistical Quality Assurance and Control Chart Technology
GB/T 32464-2015 Chemical Analysis Laboratory Internal Quality Control Utilization Control Chart Verification Analysis System
GB/T 32465-2015 verification of chemical analysis methods and internal quality control requirements
GB/T 32467 Chemical Analysis Method Verification Verification and Internal Quality Control Terms and Definitions
GB/T 33464 Guidelines for the preparation and use of standard operating procedures for chemical analysis
SN1482 Laboratory Internal Quality Control Method MR Statistics and Dynamic Tracking Monitoring Technology
ISO 11843-1 Test Capability Part 1. Terms and Definitions (Capability of detection-Part 1. Termsanddef-
Initions)
ISO 11843-2 Detection Capability Part 2. Linearity Correction Method (Capability of detection-Part 2. Methodology
Inthelinearcalibrationcase) […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 54 pages — is available in the English PDF.
Similar standards
How to Download GB/T 35657-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 35657-2017
$870.00