GB/T 34806-2017Determination of 13 kinds of prohibited colourants in cosmetics—High performance liquid chromatography (English PDF)
化妆品中13种禁用着色剂的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 34806-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 1, 2017
Implementation date
May 1, 2018
Scope
GB/T 34806-2017 is the English-translated version of 化妆品中13种禁用着色剂的测定 高效液相色谱法.
GB/T 34806-2017 is the Chinese standard "Determination of 13 kinds of prohibited colourants in cosmetics -- High performance liquid chromatography".
Its scope clause reads: This Standard specifies the high performance liquid chromatography (HPLC) method and its mass spectrometry confirmation method for the determination of 13 kinds of prohibited colourants in cosmetics (Acid Yellow 36, Acid Violet 49, Pigment Red 53, Solvent Red 49, Basic Violet 1, Disperse Yellow 3, Basic Violet 3, Pigment Orange 5, Sudan I, Sudan II, Solvent Blue 35, Sudan IV, and Basic Violet 10).
This Standard applies to the quantitative determination of 13 kinds of prohibited colourants in lipsticks and other wax-based cosmetics, as well as nail polishes, and powders.
The detection-limit and quantitation-limit for the 13 kinds of prohibited colourants in this Standard are shown in Table A.1. Its clauses include method summary; reagents and materials; instruments and apparatuses; sample preparation; determination steps; parallel test; recovery and precision.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on NOVEMBER 01, 2017 and took effect on MAY 01, 2018.
Found what you need?
Document preview — GB/T 34806-2017
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction4
- 1 Scope5
- 2 Normative references5
- 3 Method summary5
- 4 Reagents and materials5
- 5 Instruments and apparatuses7
- 6 Sample preparation7
- 7 Determination steps7
- 8 Parallel test11
- 9 Recovery and precision11
- Appendix A (Informative) Detection-limit and quantitation-limit for 13 kinds of prohibited colourants12
- Appendix B (Informative) Standard substance name (English name), CI number, CAS number, molecular formula, molecular structural formula, relative molecular mass, and purity13
- Appendix C (Informative) Liquid chromatography separation chromatogram and mass spectrometry confirmatory total ion current mass spectrogram of standard substances for 13 kinds of prohibited colourants15
1 Scope
This Standard specifies the high performance liquid chromatography (HPLC) method and its mass spectrometry confirmation method for the determination of 13 kinds of prohibited colourants in cosmetics (Acid Yellow 36, Acid Violet 49, Pigment Red 53, Solvent Red 49, Basic Violet 1, Disperse Yellow 3, Basic Violet 3, Pigment Orange 5, Sudan I, Sudan II, Solvent Blue 35, Sudan IV, and Basic Violet 10).
This Standard applies to the quantitative determination of 13 kinds of prohibited colourants in lipsticks and other wax-based cosmetics, as well as nail polishes, and powders.
The detection-limit and quantitation-limit for the 13 kinds of prohibited colourants in this Standard are shown in Table A.1.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Method summary
Disperse the sample to be tested in tetrahydrofuran; then add a methanol-water mixture containing ammonium acetate; extract the target analyte by ultrasonication; centrifuge and filter; separate by reversed-phase high-performance liquid chromatography; detect by diode array; quantify by external standard method of standard curve. Samples determined to be positive by liquid chromatography need to be confirmed by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).
4 Reagents and materials
Unless otherwise specified, all reagents used are of analytical grade and the water used is Grade I water as specified in GB/T 6682.
4.1 The standard substance name (English name), CI number, CAS number, molecular formula, molecular structural formula, relative molecular mass, and purity are shown in Table B.1.
4.2 Tetrahydrofuran.
4.3 Methanol.
4.4 Methanol-Tetrahydrofuran (1+1) solution. Mix tetrahydrofuran and methanol (4.3) in a 1+1 (V+V) ratio.
4.5 Methanol. chromatographic pure, used for preparing the mobile phase during mass spectrometry confirmation.
4.6 Acetonitrile. chromatographic pure.
4.7 Ammonium acetate. chromatographic pure.
4.8 Formic acid. chromatographic pure.
4.9 Methanol-Ammonium acetate aqueous solution. Take 0.77 g of ammonium acetate; add it to 100 mL of water and dissolve it completely; then add 100 mL of methanol (4.3) and mix thoroughly to obtain a methanol-ammonium acetate aqueous solution with an ammonium acetate concentration of 50 mmol/L.
4.10 Preparation of standard stock solutions. Weigh 10 mg (accurate to 0.1 mg) each of Pigment Orange 5 and Disperse Yellow 3; dissolve them in tetrahydrofuran and methanol respectively; fix the volume to 50 mL to prepare a standard stock solution with a concentration of 0.2 mg/mL. Weigh 10 mg (accurate to 0.1 mg) each of Pigment Red 53 and Sudan IV; dissolve them separately in dimethyl sulfoxide and tetrahydrofuran; then dilute to 10 mL to prepare a standard stock solution with a concentration of 1 mg/mL. Weigh 10 mg (accurate to 0.1 mg) each of the remaining 8 kinds of standard substances (except Pigment Orange 5, Disperse Yellow 3, Pigment Red 53, Sudan IV, and Basic Violet 10); dissolve them in methanol, and dilute to 10 mL to prepare standard stock solutions with a concentration of 1 mg/mL for each target substance. Since Basic Violet 10 is actually the hydrochloride salt of Solvent Red 49, and its elution time is the same as that of Solvent Red 49 under the same chromatographic conditions, the method cannot distinguish between Basic Violet 10 and Solvent Red 49.Therefore, when preparing the standard stock solution, either one can be selected according to the availability of the standard substance.
4.11 Preparation of standard solutions. Accurately transfer 1 mL each of the standard stock solutions of Pigment Orange 5 and Disperse Yellow 3, and 200 µL each of the remaining standard stock solutions into the same 10 mL volumetric flask; use methanol-tetrahydrofuran (1+1) to dilute to the mark, to prepare a mixed standard solution of 20 µg/mL; then, use methanol-tetrahydrofuran (1+1) to serially dilute to prepare a series of mixed standard solutions of 5 µg/mL, 2 µg/mL, 1 µg/mL, 0.5 µg/mL, and 0.2 µg/mL for the preparation of standard curves.
5 Instruments and apparatuses
5.1 High performance liquid chromatography - diode array detector.
5.2 High performance liquid chromatography-tandem quadrupole mass spectrometer, equipped with an ESI ion source (for confirmation).
5.3 Analytical balance. sensitivity 0.1 mg; 0.01 mg.
5.4 Vortex mixer.
5.5 Ultrasonic cleaner.
5.6 Centrifuge. speed not less than 5 000 r/min, centrifuge tube capacity 10 mL.
5.7 Pipette or pipettor.
6 Sample preparation
Weigh approximately 0.2 g (accurate to 1 mg) of the cosmetic sample to be tested into a centrifuge tube; add 6 mL of tetrahydrofuran; vortex and sonicate for 10 min to disperse the sample and extract the target substance (In the case of lipstick sample that cannot be dispersed, appropriately heat in an 80 °C water bath for 1 min ~ 2 min to disperse it); continue to add approximately 4 mL of methanol-ammonium acetate aqueous solution (4.9) to the centrifuge tube to make the extraction solution to 10 mL; vortex to mix well; sonicate for 10 min; then centrifuge at 5 000 r/min for 10 min. Take the clear extract; filter it through a 0.45 µm microporous membrane; then test it.
7 Determination steps
7.1 Reference conditions for liquid chromatography analysis
Chromatographic column. Poroshell 120 EC-C18 (2.7 µm, 3.0 mm × 100 mm) or equivalent.
Mobile phase. mobile phase A, 10 mmol/L ammonium acetate solution; mobile phase B, acetonitrile. Column temperature. 35 °C; flow rate. 0.5 mL/min.
Injection volume. 2 µL; detection wavelength. 416 nm, 514 nm, 590 nm. Gradient elution conditions. see Table 1. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 34806-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 34806-2017