GB/T 34334-2017Test method of mirror shape for solar collector (English PDF)
光热玻璃反射镜面形测试方法
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for GB/T 34334-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 14, 2017
Implementation date
September 1, 2018
Scope
GB/T 34334-2017 is the English-translated version of 光热玻璃反射镜面形测试方法.
GB/T 34334-2017 is the Chinese standard "Test method of mirror shape for solar collector". Its scope clause reads: This Standard specifies the terms and definitions, symbols, test principle, instruments, test procedures, parameter calculation and test report of mirror shape for solar collector based on stripe reflection principle.
This Standard is applicable to the tests of mirror shape for slot, dish, tower solar collectors. Its clauses include terms and definitions; symbols; test principle; instruments; testing process; parameter calculation; test report.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on OCTOBER 14, 2017 and took effect on SEPTEMBER 1, 2018.
Found what you need?
Document preview — GB/T 34334-2017
National Standard of the People's Republic of China
- ICS
- 81.040.30
- Classification
- Q 34
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Terms and definitions4
- 3 Symbols5
- 4 Test principle6
- 5 Instruments6
- 6 Testing process11
- 7 Parameter calculation11
- 8 Test report18
Foreword
This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This Standard specifies the terms and definitions, symbols, test principle, instruments, test procedures, parameter calculation and test report of mirror shape for solar collector based on stripe reflection principle.
This Standard is applicable to the tests of mirror shape for slot, dish, tower solar collectors.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1 Height deviation
height deviation in the reference direction between the actual mirror and the ideal mirror
2.2 Slope
the tangent of the angle between the tangent plane and the reference plane at a point on the reflector
2.3 Slope deviation
the angle between the actual mirror normal and the ideal mirror normal at a point on the mirror
2.4 Focus deviation
under use conditions, the distance from the reflected light to the mirror's ideal focus or focal line
2.5 Focus deviation distribution
the distribution of focus point deviation of the mirror on the reference plane
2.6 Parallel ray intercept factor
parallel light rays evenly distributed along the ideal direction of incidence, the ratio of the amount of light reflected by the mirror to the heat sink to the amount of light incident on the mirror
2.7 Sun intercept factor
the ratio of the amount of sunlight reflected in the ideal direction of incidence to the heat sink by the mirror TO the amount of light incident on the mirror
2.8 Intercept factor distribution
take the diameter of the heat-absorbing device as the abscissa, the actual mirror-parallel light-cutting factor of the corresponding caliber as the ordinate, form the distribution curve of the parallel light-cutting factor under different caliber conditions
2.9 Concentrating quality factor
the ratio of the area under the actual mirror parallel light cut-off factor distribution curve TO the area under the ideal mirror parallel light cut-off factor distribution curve with a use aperture of the heat-absorbing device as the boundary condition of the parallel light cut-off factor distribution curve
3 Symbols
The following symbols apply to this document.
CQF. concentrating quality factor FDx. mean square root of focus deviation in x-axis direction in the use coordinate system (xyz) fdx (X, Y). focus deviation distribution in X-axis direction in the measurement coordinate system (XYZ)
FDy. mean square root of focus deviation in y-axis direction in the use coordinate system (xyz) fdy (X, Y). focus deviation distribution in Y-axis direction in the measurement coordinate system (XYZ)
HD. mean square root of height deviation in the measurement coordinate system (XYZ) hd (X, Y). mirror height deviation distribution in the measurement coordinate system (XYZ)
IC. parallel ray intercept factor ICsun. sun intercept factor RIC(phi). parallel ray intercept factor distribution of heat absorption device g (X, Y) - the slope at some fixed point (X, Y) on the tested mirror; its modulus value is calculated according to equation (4).
5 Instruments
5.2.4 Obtain mirror shape parameters
5.2.4.1 According to the mirror shape obtained from the measurement coordinate system, the following parameters can be calculated. height deviation distribution hd(X, Y), mean square root of height deviation HD, slope deviation distribution sdX(X, Y) in the X axis direction, slope deviation distribution sdY(X, Y) in the Y axis direction, mean square root of slope deviation in X-axis direction SDX, mean square root of slope deviation in Y-axis direction SDY, focus deviation distribution in X-axis direction fdX (X, Y), focus deviation distribution in X-axis direction fdY (X, Y).
5.2.4.2 Convert the slope distribution gx (X, Y), gy (X, Y) in the measurement coordinate system XYZ to the slope distribution gx (x, y), gy (x, y) in the use coordinate system xyz according to the use requirements. In the use coordinate system xyz, the z-axis is the direction of the ideal incident light, the y-axis is the mirror bus direction, and the x-axis is the vertical yoz plane direction. Use linear interpolation or area projection weighing methods, in the use coordinate system xyz plane, according to the parameter calculation requirements, form an equal interval slope distribution. Combined with the sun divergence angle and the diameter of the heat collector, the following parameters can be calculated. mean square root of focus deviation in x-axis direction FDx, mean square root of focus deviation in y-axis direction FDy, parallel ray intercept factor IC, sun intercept factor ICsun, parallel ray intercept factor distribution of heat absorption device RIC(phi), concentrating quality factor CQF.
5.3 Requirements
5.3.1 Sample bench
The sample bench shall satisfy the positioning installation of the tested sample. The sample positioning accuracy shall be less than 1mm.
5.3.2 Graphic generator
The graphic generator can be implemented by a display or projection method that can generate a dynamic pattern. The display area shall meet the complete reflective mirror test of the tested sample. sdX - the slope deviation of the surface test point of the test sample in the X- axis direction, in milliradians (mrad);
beta X - the angle between the projection direction of the test point's ideal normal on the XOZ plane and the Z axis, in milliradians (mrad).
See equation (8) for the calculation of the mean square root of slope deviation of the tested sample SDX in X-axis direction. where, SDX - the mean square root of slope deviation of the tested sample, in milliradians (mrad); sdxi - the slope deviation of a certain test point on the surface of the test sample in the direction of the X-axis direction, in milliradians (mrad); n - total number of test points.
The slope deviation distribution sdX (X, Y) in the X-axis direction is the distribution of the slope deviation of each test point on the sample surface on the XOY coordinate plane sdXi, represented in two-dimensional error map.
7 Parameter calculation
7.2.2 Mean square root of slope deviation in Y-axis direction SDY
In the measurement coordinate system, the slope deviation of the test point on the tested sample surface in Y-axis direction sdY is equal to the angle between the actual normal direction and the ideal normal direction of the test point on the YOZ projection plane. See equation (9) for the calculation. where, sdY - the slope deviation of the test point on the tested sample surface in Y-axis direction, in milliradians (mrad);
7.3.3 Mean square root of focus deviation in y-axis direction FDy
See equation (13) for the calculation of focus deviation fdY in the Y direction. where, fdY - the focus deviation of the test point on the tested sample surface along with the Y direction, in millimeters (mm); sdY - the slope deviation of the test point on the tested sample surface in the Y direction, in milliradians (mrad);
L - the distance from the test point on the tested sample surface to the ideal focus or focal line, in millimeters (mm). Convert the measurement coordinate system to use coordinate system.
Interpolation and other methods can be used to achieve uniform light sampling and obtain the focus deviation fdY in the use coordinate system. The mean square root of focus deviation in y-axis direction FDy is calculated according to equation (14). where, FDy - the mean square root of focus deviation of tested sample in the y-axis direction; fdYi - the focus deviation of a test point on the tested sample surface along with the Y direction; m - total number of data points.
Use XOY plane as reference plane. The focus deviation distribution on the Y- axis direction fdY (X, Y) is the distribution of the focus deviation of each test point on the sample surface on the XOY coordinate plane fdYi, represented in two-dimensional error map.
7.4 Intercept factor calculation
7.4.1 Calculation principle
The intercept factor can be calculated by ray tracing simulation, and the number […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Similar standards
How to Download GB/T 34334-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 34334-2017
$185.00