GB/T 34270-2017Determination of polychorinated biphenyls and hexachlorobenzene in feeds—Gas chromatography (English PDF)
饲料中多氯联苯与六氯苯的测定 气相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 34270-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 7, 2017
Implementation date
April 1, 2018
Scope
GB/T 34270-2017 is the English-translated version of 饲料中多氯联苯与六氯苯的测定 气相色谱法.
GB/T 34270-2017 is the Chinese standard "Determination of polychlorinated biphenyls and hexachlorobenzene in feeds - Gas chromatography". Its scope clause reads: This standard specifies the gas chromatography method for the determination of indicative polychlorinated biphenyls and hexachlorobenzene in feed.
This standard is applicable to the determination of single or multiple contents of indicator polychlorinated biphenyls (PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180) and hexachlorobenzene (HCB) in compound feed, concentrated feed, additive premix, feed raw materials (except oils and fats) and feed additive copper sulfate.
The detection limits of indicative polychlorinated biphenyls and hexachlorobenzene in this standard are both 0.5 µg/kg, and the quantification limits are both 2 µg/kg.
Its clauses include principle; reagents and materials; instruments and equipment; sampling and specimen preparation; analysis steps; result calculation; repeatability.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on SEPTEMBER 7, 2017 and took effect on APRIL 1, 2018.
Found what you need?
Document preview — GB/T 34270-2017
National Standard of the People's Republic of China
- ICS
- 65.120
- Classification
- B 46
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Principle4
- 4 Reagents and materials5
- 5 Instruments and equipment6
- 6 Sampling and specimen preparation6
- 7 Analysis steps6
- 8 Result calculation8
- 9 Repeatability9
- Appendix A (Informative) Chinese and English names, molecular formulas and CAS numbers of indicative PCBs and HCB10
- Appendix B (Informative) Chromatogram of the indicative PCB and HCB standard working solution11
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the gas chromatography method for the determination of indicative polychlorinated biphenyls and hexachlorobenzene in feed.
This standard is applicable to the determination of single or multiple contents of indicator polychlorinated biphenyls (PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180) and hexachlorobenzene (HCB) in compound feed, concentrated feed, additive premix, feed raw materials (except oils and fats) and feed additive copper sulfate.
The detection limits of indicative polychlorinated biphenyls and hexachlorobenzene in this standard are both 0.5 µg/kg, and the quantification limits are both 2 µg/kg.
2 Normative references
The following documents are essential to the application of this document. For referenced documents with dates, only the versions corresponding to the dates are applicable to this document; for referenced documents without dates, the latest versions (including all amendments) are applicable to this document.
GB/T 603 Chemical reagent - Preparations of reagent solutions for use in test methods
GB/T 6682 Water for analytical laboratory use - Specification and test methods
GB/T 14699.1 Feed - Sampling
GB/T 20195 Animal feed - Preparation of test samples
3 Principle
The indicative polychlorinated biphenyls and hexachlorobenzene in the sample are extracted with n-hexane acetone solution and sulfonated with concentrated sulfuric acid, then determined by gas chromatography-electron capture detector (ECD) and quantified by external standard method.
4 Reagents and materials
Unless otherwise specified, all reagents are analytically pure and conform to the secondary water specified in GB/T 6682. The preparations used in the test shall be prepared in accordance with the provisions of GB/T 603. In the analysis, high-purity reagents of pesticide residue grade are used, and blank tests are performed.
Polychlorinated biphenyls and hexachlorobenzene shall not be detected when the organic reagents are concentrated 10,000 times.
4.1 N-Hexane: Pesticide residue grade.
4.2 Acetone: pesticide residue grade.
4.3 Anhydrous sodium sulfate: It shall be baked at 660 °C for at least 6 hours, stored in a sealed container in a desiccator, and used within one month.
4.4 Saturated sodium sulfate solution.
4.5 Concentrated sulfuric acid: a guaranteed reagent.
4.6 N-Hexane acetone solution: 1+1. Take 500 mL of n-hexane and 500 mL of acetone and mix them evenly.
4.7 Indicative polychlorinated biphenyls (PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180) and hexachlorobenzene standards: with a purity of >=98.0%. The Chinese names, English names, molecular formulas and CAS numbers of the substances are shown in Table A.1.
4.8 Standard stock solution: Weigh the hexachlorobenzene standard and prepare a 100 µg/mL standard stock solution with n-hexane. Polychlorinated biphenyls are liquid standards and are diluted with n-hexane to 100 µg/mL standard stock solutions. Store at -20 °C, valid for 6 months.
4.9 Mixed standard stock solution: Take appropriate amounts of hexachlorobenzene and indicative polychlorinated biphenyl standard stock solutions (4.8) respectively, and dilute with n-hexane to a mixed standard stock solution with a concentration of 1 µg/mL; store at -20 °C, valid for 3 months.
4.10 Diatomaceous earth.
4.11 Microporous filter membrane: 0.22 µm, organic phase
WARNING: Polychlorinated biphenyls are carcinogens and must be handled with safety protection equipment.
Weigh about 10 g (accurate to 0.001 g) of the specimen into a mortar, add 1 g of diatomaceous earth (4.10), grind evenly and transfer to a 34 mL ASE extraction cell.
Use n-hexane acetone solution (4.6) as the extractant, at a temperature of 100 °C, under a pressure of 10.3 MPa, preheat for 5 min, and statically extract for 10 min; quickly rinse the sample with 60% of the extraction cell volume of the extractant, and perform accelerated solvent extraction under nitrogen purge for 90 seconds. Collect all the extract and transfer it to a 100 mL pear-shaped flask, rotate and evaporate it under reduced pressure at 35 °C until almost dry, and dissolve it with 5 mL of n-hexane.
5 Instruments and equipment
5.1 Gas chromatograph: It is equipped with an electron capture detector (ECD).
5.2 Analytical balance: The sensitivities are 0.1 mg and 0.01 mg.
5.3 Soxhlet extractor.
5.4 Accelerated solvent extraction (ASE) system: It is equipped with a 34 mL extraction cell.
5.5 Mortar.
5.6 Centrifuge: The speed is >10000 r/min.
5.7 Termovap Sample Concentrator.
5.8 Vortex mixer.
5.9 Ultrasonic cleaner.
5.10 Rotary evaporator.
6 Sampling and specimen preparation
Take a representative sample according to GB/T 14699.1 and reduce the sample by quartering. Prepare the specimen according to GB/T 20195; grind it, pass it through a 0.45 mm mesh sieve, mix it, put it into a sealed container, and store it at a low temperature away from light for later use.
7 Analysis steps
7.1 Extraction
7.1.1 Method 1: Soxhlet extraction
Weigh about 5 g (accurate to 0.001 g) of the specimen, add 10 g of anhydrous sodium sulfate (4.3), wrap it with filter paper and place it in a Soxhlet extractor; add 100 mL of n-hexane (4.1), and extract for 10 hours (with a reflux rate of 10~12 times per hour); after cooling, transfer the extract into a 100 mL pear-shaped flask, rotate and evaporate it under reduced pressure at 35 °C to near dryness, and dissolve it with 5 mL of n-hexane for purification.
7.1.2 Method 2: Accelerated solvent extraction
7.2 Purification
Add 1 mL of concentrated sulfuric acid (4.5) for sulfonation, vortex for 30 seconds, centrifuge for 5 minutes, and discard the lower sulfuric acid layer; repeat the above operation until the organic phase is colorless; add 15 mL of saturated sodium sulfate aqueous solution (4.4), shake, let it stand, discard the water phase, and repeat washing until the pH of the water phase is 7. Take the organic phase and blow dry it with nitrogen at 35 °C, make it up to 1 mL with n-hexane, vortex for 30 seconds, filter it with a filter membrane, and then determine it by gas chromatography.
7.3 Determination
7.3.1 Standard curve drawing
Accurately measure out an appropriate amount of the indicative PCB or HCB mixed standard stock solution (4.9), dilute it with n-hexane to mixed standard working solutions with a concentration of 0.01 µg/mL, 0.02 µg/mL, 0.10 µg/mL, 0.50 µg/mL, and 1.00 µg/mL for gas chromatography determination. Draw a standard curve with the concentration of each target substance in the above solutions as the abscissa and the corresponding peak area as the ordinate.
7.3.2 Gas chromatography reference conditions
Chromatographic column: 50% phenyl 50% methyl polysiloxane capillary gas chromatography column (DB-17MS), with a specification of 30 m×0.25 mm×0.25 µm, or equivalent.
Column temperature: Maintain at 60 °C for 1 min, raise the temperature to 180 °C at a rate of 10 °C/min, and then increase the temperature to 280 °C at a rate of 4 °C/min and maintain for 10 min. Inlet temperature: 300 °C; non-split injection, split after 1 min. Electron capture detector (ECD) temperature: 300 °C. Column flow rate: 1.0 mL/min.
7.3.3 Qualitative and quantitative determination
Respectively take appropriate amounts of the indicative PCB and HCB mixed standard working solution specified in 7.3.1 and the purified sample solution specified in 7.2 for determination. The chromatographic peak retention time shall be used for qualitative analysis. The relative deviation between the sample and the standard retention time shall not exceed 0.5%. The chromatographic peak signal-to-noise ratio (S/N) of the polychlorinated biphenyls (PCBs) shall be greater than 3.
The chromatographic peak area response value is used for quantification of single-point or multi-point calibration. The chromatogram of the indicative PCB and HCB mixed standard working solution is shown in Appendix B.
8 Result calculation
The content Xi of indicative PCBs and hexachlorobenzene in the specimen is expressed as a mass fraction, in mg/kg, and is calculated according to formula (1) for the single-point calibration method and formula (2) for the multi-point calibration method:
Single-point calibration method: where: m -- Mass of the specimen, in grams (g);
Ai -- Peak area of indicative polychlorinated biphenyls or hexachlorobenzene to be detected in the specimen;
Asi -- Peak area of indicative polychlorinated biphenyls or hexachlorobenzene in the standard working solution; ci -- Concentration of indicative polychlorinated biphenyls or hexachlorobenzene in the standard working solution, in micrograms per milliliter (µg/mL); V -- The metered volume before injection, in milliliters (mL).
The determination result is expressed as the arithmetic mean of parallel determinations, and the result is rounded to three significant figures. Multi-point calibration method: […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 34270-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 14699.1-2005 — Feeding stuffs -- Sampling
GB/T 20195-2024 — Animal feed - Preparation of test samples
GB/T 603-2023 — Chemical reagent - Preparations of reagent solutions for use in test methods
Secure payment via Stripe
Payments accepted
GB/T 34270-2017
$145.00