GB/T 34135-2017Industrial cable reels (English PDF)
工业用电缆卷盘
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for GB/T 34135-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
July 31, 2017
Implementation date
February 1, 2018
Scope
GB/T 34135-2017 is the English-translated version of 工业用电缆卷盘.
GB/T 34135-2017 — This standard specifies the industrial cable reel structure, mechanical properties, electrical performance and other technical requirements. This standard applies to industrial, outdoor and indoor use, the rated voltage does not exceed 690Vd.c.
Or ac and 500Hza.c., Cable reel with one non-removable flexible cable up to 63A. Electrical accessories used in the cable reel should be with GB/T 11918.1 or GB/T 11918.2 requirements.
This standard applies to. --- Equipped with a plug or appliance input socket and at least one output socket in accordance with GB/T 11918.1 or GB/T 11918.2 Mobile cable reel; --- At least equipped with an output socket in line with GB/T 11918.1 or GB/T 11918.2 fixed cable reel; --- Use the ambient temperature is usually between -25 °C ~ 40 °C. Industrial cable reels can be used in construction sites, agricultural production, commercial and home.
This standard applies to both low voltage devices used in the cable reel. In special circumstances, such as cabins, vehicles and similar occasions, or prone to explosion in the area, there may be additional requirements.
Note. Additional specifications for cable reels in excess of 63A are currently under consideration.
Found what you need?
Document preview — GB/T 34135-2017
National Standard of the People's Republic of China
- ICS
- 29.120.99
- Classification
- K 65
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General
- 5 Standard rating
- 6 Categories
- 7 Logo
- 8 Size
- 9 Anti-shock protection
- 10 Grounding measures
- 11 Terminal
- 12 Interlocking
- 13 Aging of rubber and thermoplastic materials
- General structure
- 15 Socket structure
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the redrafted law to amend the use of IEC 61316:1999 "industrial cable reel." this standard IEC 61316:1999 technical differences and the reasons are as follows.
--- On normative references, this standard made a technical difference with the adjustment to adapt to China's technical conditions, adjust the situation Concentration reflected in the second chapter "Normative references", the specific adjustments are as follows.
- Replaced IEC 60050-195:1998 with GB/T 2900.73-2008 modified to adopt international standards;
- Equivalent to the use of international standards GB/T 4208 instead of IEC 60529:1989;
- Equivalent to the use of international standards GB/T 5013.4 instead of IEC 60245-4:1994;
- Replaced IEC 60309-1:1999 with GB/T 11918.1-2014 modified to adopt international standards;
- Replaced IEC 60309-2:1999 with GB/T 11918.2 modified to adopt international standards;
- IEC 60245 (all sections) removed by reference.
This standard also made the following editorial changes.
--- According to the relevant provisions of GB/T 1.1, in Chapter 1 "Scope" in paragraph 1 added "This standard specifies the industrial cable reel Structure, mechanical properties, electrical performance and other technical requirements ";
--- According to the relevant provisions of GB/T 1.1, 10.8.1, 10.8.2 changed to listed items;
--- Remove some of the IEC 61316:1999 applicable to other countries and regions of the Notes, such as 14.9 Note;
--- In accordance with the relevant provisions of GB/T 1.1, the 14.9 line item dash instead of letters;
--- According to GB/T 1.1 on the various articles should be unified with the provisions of the deletion of the title 10.2,10.3,10.4, an increase of 23.1, 23.2, 23.3, 23.4, 23.5
--- According to the relevant provisions of GB/T 1.1, GB/T 2900.73-2008 adjusted to the reference.
This standard proposed by the China Electrical Equipment Industry Association.
This standard by the National Electrical Accessories Standardization Technical Committee (SAC/TC67) centralized.
This standard was drafted unit. China Electric Apparatus Research Institute Co., Ltd., Shantou East Asia Electric Factory, Bulls Group Co., Ltd., Hangzhou Hongyan Electric Co., Ltd., Ningbo Wei Er Electric Co., Ltd., Shandong Wild Wolf Electric Co., Ltd., Zhejiang Chint Construction Electric Co., Ltd., Beijing Branch can Bo Electronic Technology Co., Ltd., Yuehua Holdings Group Co., Ltd., Ningbo Yinghua Electric Co., Ltd., Shantou Branch Run mechanical and electrical equipment Co., Ltd., Wei Kai Detection Technology Co., Ltd., Guangdong CEC Industry and Daily Electrical Industry Productivity Promotion Center Ltd..
1 Scope
This standard specifies the industrial cable reel structure, mechanical properties, electrical performance and other technical requirements.
This standard applies to industrial, outdoor and indoor use, the rated voltage does not exceed 690Vd.c. Or ac and 500Hza.c., Cable reel with one non-removable flexible cable up to 63A. Electrical accessories used in the cable reel should be with GB/T 11918.1 or GB/T 11918.2 requirements.
This standard applies to.
--- Equipped with a plug or appliance input socket and at least one output socket in accordance with GB/T 11918.1 or GB/T 11918.2 Mobile cable reel;
--- At least equipped with an output socket in line with GB/T 11918.1 or GB/T 11918.2 fixed cable reel;
--- Use the ambient temperature is usually between -25 °C ~ 40 °C.
Industrial cable reels can be used in construction sites, agricultural production, commercial and home.
This standard applies to both low voltage devices used in the cable reel.
In special circumstances, such as cabins, vehicles and similar occasions, or prone to explosion in the area, there may be additional requirements.
Note. Additional specifications for cable reels in excess of 63A are currently under consideration.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2423.55 Environmental testing for electric and electronic products Part 2. Test methods Test Eh Hammer test (GB/T 2423.55-2006, IEC 60068-2-75:1997, IDT) GB/T 4208 enclosure protection (IP code) (GB/T 4208-2008, IEC 60529:2001, IDT) GB/T 5013.4 Rated voltage 450/750V and below rubber insulated cables Part 4. Cords and flexible cables (GB/T 5013.4-2008, IEC 60245-4:2004, IDT) GB/T 11918.1-2014 Industrial plugs and sockets and couplers Part 1. General requirements (IEC 60309-1:2012, MOD) GB/T 11918.2 Industrial plugs and sockets - Part 2. Dimensional compatibility of electrical accessories with pins and inserts Interchangeability requirements (GB/T 11918.2-2014, IEC 60309-2:2012, MOD)
3 Terms and definitions
The following terms and definitions apply to this document.
Note Where the term "voltage" and "current" are used, they are both dc or ac rms values.
Rated operating voltage Manufacturer's specified voltage on the cable reel.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.55Environmental testing - Part 2: Test methods - Test Eh: Hammer tests
- GB/T 2423.55-2006Environmental testing - Part 2: Test methods - Test Eh: Hammer tests
- GB/T 4208Degrees of protection provided by enclosures (IP code)
- GB/T 4208-2008Degrees of protection provided by enclosures (IP code)
- GB/T 5013.4Rubber insulated cables of rated voltages up to and including 450/750V -- Part 4: Cords and flexible cables
- GB/T 5013.4-2008Rubber insulated cables of rated voltages up to and including 450/750V -- Part 4: Cords and flexible cables
IEC 60068 · IEC 60529 · IEC 60245 · IEC 60309
How to Download GB/T 34135-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 11918.1-2014 — Plugs, socket-outlets and couplers for industrial purposes -- Part 1: General requirements
GB/T 11918.2-2025 — Plugs; fixed or portable socket-outlets and appliance inlets for industrial purposes—Part 2: Dimensional compatibility requirements for pin and contact-tube accessories
GB/T 2423.55-2023 — Environmental testing - Part 2: Test methods - Test Eh: Hammer tests
Secure payment via Stripe
Payments accepted
GB/T 34135-2017
$305.00