Valid

GB/T 33983.2-2017Direct methanol fuel cell system—Part 2: Performance test method (English PDF)

直接甲醇燃料电池系统 第2部分:性能试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 33983.2-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 12, 2017

Implementation date

February 1, 2018

Scope

GB/T 33983.2-2017 is the English-translated version of 直接甲醇燃料电池系统 第2部分:性能试验方法.

GB/T 33983.2-2017 is Part 2 of the two-part GB/T 33983 series on direct methanol fuel cell systems, the first part covering safety, and this record is served with the official English translation.

It specifies the test items and test methods for the power generation performance and the environmental adaptability of direct methanol fuel cell systems, and it divides the systems into power grades: Grade I for micro systems of rated power up to 240 W and Grade II for mobile systems above 240 W and up to 1000 W, with the test items required of each.

The tests cover the power generation performance under specified operating conditions, such as output voltage, output power, start time and fuel consumption, the performance under special operating conditions, such as generation after deactivation, and the environmental adaptability under specified conditions of high and low temperature, high and low humidity, drop and vibration; the vibration test applies a sine sweep from 7 Hz to 200 Hz and back within 15 min, repeated twelve times, perpendicular to the mounting plane.

Clause 6 fixes the test report as a heading page, a summary report, a detailed report and a complete report, and Annex A gives an informative template for the summary report.

It applies to direct methanol fuel cell systems fuelled by methanol or aqueous methanol with a rated power not exceeding 1000 W, and systems above 1000 W may refer to it. It was issued on 12 July 2017 and has applied since 1 February 2018.

Found what you need?

Document preview — GB/T 33983.2-2017

National Standard of the People's Republic of China

ICS
27.070
Classification
K 82

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references5
  • 3 Terms and definitions5
  • 4 Requirements6
  • 4.1 General6
  • 4.2 Standard atmosphere of the test7
  • 4.3 Test equipment and inspection devices7
  • 5 Test methods8
  • 5.1 Performance test8
  • 5.2 Environmental adaptability test method10
  • 6 Test report12
  • 6.1 Heading page12
  • 6.2 Summary report13
  • 6.3 Detailed report13
  • 6.4 Complete report13
  • Annex A (informative) Summary test report template15

Foreword

GB/T 33983 "Direct methanol fuel cell system" includes the following two parts.

- Part 1. Safety;

- Part 2. Performance test method.

This Part is Part 2 of GB/T 33983.

This Part is drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This Part of GB/T 33983 specifies the test items and test methods in terms of power generation performance and environmental adaptability for direct methanol fuel cell systems, classifies the direct methanol fuel cell systems with different power grades into Grade I and Grade II, see Table 1, and distinguishes the test items they need.

Table 1 -- Classification of direct methanol fuel cell power generation systems

Battery type Rated power P Power grade

Micro direct methanol fuel cell power generation system P <= 240 W Grade I

Mobile direct methanol fuel cell power generation system 240 W < P <= 1000 W Grade II

The power generation performance and environmental adaptability test items and test methods specified in this Part include.

a) Power generation performance under specified operating conditions. e.g. output voltage, output power, start time, fuel consumption, etc.;

b) Power generation performance under special operating conditions. e.g. power generation after deactivation, etc.;

c) Environmental adaptability under specified conditions. e.g. high temperature, low temperature, high humidity, low humidity, drop, vibration etc.

This Part applies to direct methanol fuel cell systems with methanol or methanol aqueous solution as fuel and with rated power not exceeding 1000 W.

The performance test method for direct methanol fuel cell systems with a rated power greater than 1000 W may refer to this Part.

A typical direct methanol fuel cell system boundary diagram is shown in Figure 1.

5 Test methods

5.1 Performance test

5.1.1 Sample and test requirements

Each test shall be carried out more than once on one sample. Unless otherwise specified, the measured value at the end of each measurement shall be taken as the measured value. The measured values shall be averaged to obtain the average measured value. The electrical parameters shall be measured at the power interface.

5.1.2 Start time

The purpose of this test is to determine the starting time of the direct methanol fuel cell system.

Unless otherwise specified, the sample shall be placed in the test environment for at least 2 hours in the power-off state before the measurement. At the beginning of the test, connect the system power output port to the electronic load with the four-wire measurement function. Turn on the system power switch and start timing, load the electronic load until the output power is not less than 90 % of rated power and stop timing. For direct methanol fuel cell systems with a start time of less than 100 ms, the test can be skipped.

5.1.3 Rated power and rated voltage

The purpose of this test is to determine the rated power and rated voltage of the direct methanol fuel cell system. The test procedure is as follows.

a) Before the measurement, the sample shall be placed in the test environment for at least 2 hours in the power-off state. After the system is started normally, connect the system power output to the electronic load with constant power discharge mode and four-wire measurement function, make the DMFC system discharge at the rated power and record the power of the electronic load. If the system cannot produce the rated power, interrupt test, no longer carry out the test content of the following b).

b) The output voltage shall be continuously measured for at least 1 h to determine whether it is within the upper and lower limits of the rated voltage specified by the manufacturer. The rated voltage range specified by the manufacturer shall be indicated in the test report. The duration of the measurement and the fuel consumption during the measurement shall be recorded in the test report. The test procedure is as follows.

a) Before the measurement, the sample shall be in a power-off state and placed at 20 % relative humidity for at least 2 h.

5.2 Environmental adaptability test method

5.2.4 High humidity

The purpose of this test is to determine the performance of direct methanol fuel cell systems under high humidity conditions. The test procedure is as follows.

a) Before the measurement, the sample shall be in a power-off state and placed at 80 % relative humidity for at least 2 h.

5.2.5 Vibration

The purpose of this test is to evaluate the effect of vibration on the performance of direct methanol fuel cell systems. The test procedure is as follows.

a) MOUNT the direct methanol fuel cell system on the vibrating table at the intended operating position and APPLY sine wave vibration from 7 Hz to 200 Hz and from 200 Hz to 7 Hz within 15 min. The cycle is repeated 12 times. The direction of vibration shall be perpendicular to the fixed level of the system. The vibration conditions shall be determined in accordance with the clause of electronic equipment in GB/T 4798.7-2007.

5.2.6 Drop

The purpose of this test is to evaluate the effect of drop impact on the performance of […]

6 Test report

6.1 Heading page

- Place of the test;

- Name of the test;

- Date and time of the test;

- Name of the manufacturer;

- Test application organization.

6.2 Summary report

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 33983.2-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 33983.2-2017

$125.00