Valid

GB/T 32883-2016Determination of hexabromocyclododecanes in electrical and electronic products - High performance liquid chromatography-mass spectrometry (English PDF)

电子电气产品中六溴环十二烷的测定 高效液相色谱-质谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32883-2016 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

August 29, 2016

Implementation date

March 1, 2017

Scope

GB/T 32883-2016 is the English-translated version of 电子电气产品中六溴环十二烷的测定 高效液相色谱-质谱法.

GB/T 32883-2016 is the Chinese standard "Determination of Hexabromocyclododecanes in Electrical and Electronic Products - High Performance Liquid Chromatography-mass Spectrometry".

Its scope clause reads: This Standard specifies the high performance liquid chromatography-mass spectrometry of determining hexabromocyclododecanes (HBCDDs) in electrical and electronic products.

This Standard is applicable to the determination of hexabromocyclododecanes (HBCDDs) in electrical and electronic products. In accordance with this Standard, the detection limits of three HBCDDs isomers (alpha, beta, gamma) are respectively.

30 mg/kg, 20 mg/kg and 25 mg/kg. Its clauses include terms and definitions; principle; reagents or materials; instruments and equipment; samples; test procedures; test data processing; recovery rate; precision.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on AUGUST 29, 2016 and took effect on MARCH 1, 2017.

Found what you need?

Document preview — GB/T 32883-2016

National Standard of the People's Republic of China

ICS
31.020
Classification
L 10

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative References4
  • 3 Terms and Definitions4
  • 4 Principle5
  • 5 Reagents or Materials5
  • 6 Instruments and Equipment6
  • 7 Samples7
  • 8 Test Procedures7
  • 9 Test Data Processing9
  • 10 Recovery Rate10
  • 11 Precision10
  • Spectrum of Standard Substance of Hexabromocyclododecane11

1 Scope

This Standard specifies the high performance liquid chromatography-mass spectrometry of determining hexabromocyclododecanes (HBCDDs) in electrical and electronic products.

This Standard is applicable to the determination of hexabromocyclododecanes (HBCDDs) in electrical and electronic products. In accordance with this Standard, the detection limits of three HBCDDs isomers (alpha, beta, gamma) are respectively: 30 mg/kg, 20 mg/kg and 25 mg/kg.

2 Normative References

The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.

GB/T 6682-2008 Water for Analytical Laboratory Use - Specification and Test Methods

3 Terms and Definitions

The following terms and definitions are applicable to this document.

3.1 Hexabromocyclododecanes; HBCDDs

Hexabromocyclododecanes is a type of bromine-containing flame retardant. In this

Standard, hexabromocyclododecanes includes three isomers: alpha, beta, gamma.

such as: 10 mL and 100 mL, etc.

5.13 Syringe filter

0.22 µm, two-phase membrane.

5.14 Syringe

5 mL.

5.15 Scale centrifuge tube: 10 mL, with a screw cap, containing poly-fluoroethylene

gasket.

5.16 Sample tube

30 mL, with a screw cap, containing poly-fluoroethylene gasket.

5.17

Cellulose sleeve.

5.18 Filter paper

use toluene to pre-extract for above 3 times; dry it for later use.

5.19 Zeolite

use toluene to pre-extract for above 3 times; dry it for later use.

5.20 Solid phase extraction column: C18, 500 mg/6 mL; or others with equivalent

performance.

6 Instruments and Equipment

6.1 High performance liquid chromatograph-mass spectrometer, equipped with

electrospray ion source (ESI source).

6.2 Crushing device: including cutting machine or scissors, grinding machine and

freezing-crushing facility, etc. It is mainly used for crushing samples.

6.3 18-mesh standard sieve (sieve diameter

1 mm).

6.4 Electronic analytical balance

division value is 0.1 mg or above.

6.5

Soxhlet extraction device, with a condenser.

6.6

Heating device used to heat up the flask used in Soxhlet extraction device.

6.7

Nitrogen blowing instrument.

6.8

Vortex miser.

6.9 Ultrasonic instrument: ultrasonic frequency 40 kHz, ultrasonic function 400 W; or

others with equivalent performance.

6.10 Centrifuge

5,000 r/min and 12,000 r/min.

6.11

Fast solvent extraction instrument.

6.12 Heating furnace

heat up to above 400 °C.

gentle nitrogen to blow-dry it. Use methanol-water solution (5.8) to reach a constant volume of 1 mL. Conduct vortex oscillation for 1 min. Use syringe filter to filter it, or, centrifuge it at 12,000 r/min for 5 min. Take the filtrate or supernatant for later testing. If the concentration of the analyte in the sample exceeds the range of the standard curve, conduct appropriate dilution, then, determine it.

b) Ultrasonic-assisted extraction: weigh-take 0.1 g of the above-mentioned mixed sample, accurate to 0.001 g. Use filter paper (5.18) to wrap it, then, place it in a centrifuge tube (5.15); add 4 mL of toluene (5.5). In an ultrasonic instrument (6.9), conduct ultrasonic extraction for 15 min, then, centrifuge it at

5,000 r/min (6.10) for 5 min. Transfer the supernatant to the sample tube (5.16). Repeat the above steps twice, then, combine the three extracts in the same sample tube (5.16); reach a constant volume in a 100 mL volumetric flask. Before the detection, take an appropriate amount (for example, 1 mL) of the extract in a nitrogen blowing instrument; use gentle nitrogen to blow- dry it. Use methanol-water solution (5.8) to reach a constant volume of 1 mL.

Conduct vortex oscillation for 1 min. Use syringe filter to filter it, or, centrifuge it at 12,000 r/min for 5 min. Take the filtrate or supernatant for later testing. If the concentration of the analyte in the sample exceeds the range of the standard curve, conduct appropriate dilution, then, determine it.

c) Fast solvent extraction: weigh-take 0.1 g of the crushed sample, accurate to

0.001 g. Use filter paper (5.18) to wrap it, then, place it in the extraction tank to conduct fast solvent extraction (6.11). The extractant is acetone-n-hexane solution (5.7). The sample cell temperature is 120 °C; the pressure is 10.3

MPa; the heating time is 5 min; the static extraction time is 10 min; the nitrogen-blowing time is 100 s. The number of cycles is 3 times; the volume of the sample cell rinsing is 20%. After the extraction is completed, reach a constant volume in a 100 mL volumetric flask. Before the detection, take an appropriate amount (for example, 1 mL) of the extract in a nitrogen blowing instrument; use gentle nitrogen to blow-dry it. Use methanol-water solution (5.8) to reach a constant volume of 1 mL. Conduct vortex oscillation for 1 min.

Use syringe filter to filter it, or, centrifuge it at 12,000 r/min for 5 min. Take the filtrate or supernatant for later testing. If the concentration of the analyte in the sample exceeds the range of the standard curve, conduct appropriate dilution, then, determine it.

During the sample analysis, simultaneously conduct blank test and parallel test.

8.2 Determination by High Performance Liquid Chromatography-mass

Spectrometry

Different instruments being used might lead to different optimal analysis conditions.

Hence, it is impossible to provide general parameters suitable for all determinations by

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 32883-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32883-2016

$95.00