Valid

GB/T 32699-2016Test method for purity of multifunctional acrylates used for UV materials - Capillary gas chromatography (English PDF)

光敏材料用多官能团丙烯酸酯单体纯度(酯含量)的测定 毛细管气相色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32699-2016 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 14, 2016

Implementation date

January 1, 2017

Scope

GB/T 32699-2016 is the English-translated version of 光敏材料用多官能团丙烯酸酯单体纯度(酯含量)的测定 毛细管气相色谱法.

GB/T 32699-2016 is the Chinese standard "Test method for purity of multifunctional acrylates used for UV materials - Capillary gas chromatography".

Its scope clause reads: This standard specifies the method for the determination of the purity (ester content) of the polyfunctional acrylate monomer for photosensitive materials by capillary gas chromatography.

This standard is applicable to the determination of the purity (ester content) of polyfunctional acrylate monomers for photosensitive materials. Its clauses include method summary; reagents and materials; instruments and conditions.

Found what you need?

Document preview — GB/T 32699-2016

National Standard of the People's Republic of China

ICS
37.040.20
Classification
G 15

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 method summary
  • 3 reagents and materials
  • 4 instruments and conditions

1 Scope

This standard specifies the method for the determination of the purity (ester content) of the polyfunctional acrylate monomer for photosensitive materials by capillary gas chromatography.

This standard is applicable to the determination of the purity (ester content) of polyfunctional acrylate monomers for photosensitive materials.

2 method summary

A small amount of the photosensitive material was weighed with a multifunctional acrylate sample and dissolved in an appropriate amount of acetone. The gas was injected into a gas chromatograph containing an inert gas

The capillary column of the body, the multifunctional acrylate is separated from the impurities such as alcohols, other esters, ethers and unknown compounds; the separated components are measured by a detector

And record the chromatogram. Using the area normalization method, the peak area of the acrylic ester was divided by the total peak area of each component.

The relative concentration of the acid esters.

3 reagents and materials

3.1 Acetone

Analytical purity.

3.2 Hydrogen

Before use, use dehydration device, silica gel, molecular sieve or activated carbon for purification.

3.3 high purity nitrogen

purity >= 99.99%.

3.4 Air

should be non-corrosive impurities, need to use before the use of dehydration devices, silica gel, molecular sieve or activated carbon for purification.

4 instruments and conditions

4.1

Gas chromatograph (GC) and chromatographic workstations in Table 1.

Table 1

Project conditions

Capillary column

OV-170.53mm × 15m; film thickness 0.5µm; wide-hole elastic quartz cross

Column

Carrier gas with high purity nitrogen

Carrier gas flow rate 6mL/min (wire speed 15cm/s)

Oven program temperature rise

The starting temperature is 70 ° C

The initial temperature hold time is 2min ~ 5min

Heating rate of 10 °C/min

Final temperature 260 °C ~ 280 °C

End temperature retention time 10min ~ 15min

Hydrogen Flame Ionization Detector

Hydrogen 30mL/min

Air 350mL/min […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 32699-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32699-2016

$70.00