Valid

GB/T 3260.7-2013Methods for chemical analysis of tin - Part 7: Determination of aluminium content - Electrothermal atomic absorption spectrometric method (English PDF)

锡化学分析方法 第7部分:铝量的测定 电热原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 3260.7-2013 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 17, 2013

Implementation date

September 1, 2014

Scope

GB/T 3260.7-2013 is the English-translated version of 锡化学分析方法 第7部分:铝量的测定 电热原子吸收光谱法.

GB/T 3260.7-2013 is the Chinese standard "Methods for chemical analysis of tin - Part 7: Determination of aluminium content - Electrothermal atomic absorption spectrometric method".

Its scope clause reads: GB/T 3260 This section provides for the determination of tin in aluminum content electrothermal atomic absorption spectrometry methods. This section applies to the determination of tin in aluminum content.

Determination of the range of 0.00030% - 0.0040%. Its clauses include method summary; reagents; instrument.

Found what you need?

Document preview — GB/T 3260.7-2013

National Standard of the People's Republic of China

ICS
77.120.60
Classification
H 13
Replacing
GB/T 3260.7-2000

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument

1 Scope

GB/T 3260 This section provides for the determination of tin in aluminum content electrothermal atomic absorption spectrometry methods.

This section applies to the determination of tin in aluminum content. Determination of the range of 0.00030% - 0.0040%

2 Method summary

Samples with hydrochloric acid and hydrogen peroxide dissolved in hydrochloric acid and citric acid medium, electrothermal atomic absorption spectrometer at 309.3nm, Zeeman

In addition to background absorption, measuring the absorption peak area, calculated according to the content of the work curve of aluminum.

3 Reagents

Analysis of water are a water. Containers are used in the experiments with hydrochloric acid (119) was thoroughly soaked, clean water reserve.

3.1

hydrochloride (rho1.19g/mL, MOS level).

Nitrate 3.2 (rho1.42g/mL, MOS level).

3.3

Hydrogen peroxide (30%, MOS grade).

3.4

hydrochloride (19).

3.5

citric acid solution (pure class distinctions, 200g/L).

3.6 standard aluminum stock solution

Weigh 1.0000g of aluminum (wAl>=99.99%), placed in 250mL-high beaker, 25mL salt

Acid (11) and 3mL nitrate, cover sheet pan, over low heat until completely dissolved, removed, cooled, washed with water table dish and cup wall, moved

1000mL volumetric flask 25mL hydrochloric acid (11), diluted with water to volume, and mix. 1mL solution containing 1mg aluminum.

3.7

Aluminum Standard Solution A. Pipette 10.00mL aluminum standard stock solution (3.6) in 100mL volumetric flask, was added 5mL hydrochloric acid (3.1),

Dilute with water to volume, and mix. This solution 1mL containing 100µg aluminum.

3.8 aluminum standard solution B

Pipette 5.00mL aluminum standard solution (3.7) in 250mL volumetric flask, was added 12.5mL hydrochloric acid (3.1),

Dilute with water to volume, and mix. This solution 1mL containing 2µg aluminum.

4 Instrument

Graphite furnace atomic absorption spectrometer (with a Zeeman background subtraction function), with a graphite furnace atomizer, autosampler, with a hollow aluminum overcast

Pole lamps and graphite tube.

Step 5 Analysis

5.1 Sample

Table 1 sample was weighed, accurate to 0.0001g.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 3260.7

EditionTitleRevisionStatus
GB/T 3260.7-2013Methods for chemical analysis of tin - Part 7: Determination of aluminium content - Electrothermal atomic absorption spectrometric methodcurrent editionCurrent
GB/T 3260.7-2000Methods for chemical analysis of tin - Part 7: Determination of aluminium content - Electrothermal atomic absorption spectrometric methodprevious editionSuperseded

This page sells the current edition, GB/T 3260.7-2013. Earlier editions are listed for reference only.

How to Download GB/T 3260.7-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 3260.7-2013

$85.00