Scope

GB/T 32481-2026 is the English-translated version of 隧道照明用LED灯具性能规范.

GB/T 32481-2026 is the Chinese national standard covering the tunnel luminaire - the extreme luminance needed at a portal in daylight and the deep dimming in the interior, the glare control, the resistance to vibration, dust and washing, and the maintained output in a fitting nobody wants to close a tunnel to replace. It replaces GB/T 32481-2016 and has been in force since 1 November 2026, with the street lighting standard GB/T 24827-2026. It was issued on 30 April 2026 and takes effect on 1 November 2026, replacing GB/T 32481-2016. The document is under the responsibility of the China National Light Industry Council. This page is published from the official record of the 2026 edition; the clause text of a standard this recent is not yet in circulation, and the figures, limits and tables it contains are those of the document itself, delivered in full with the English translation.

Document preview — GB/T 32481-2026

National Standard of the People's Republic of China

ICS
29.140
Classification
K 73
Replacing
GB/T 32481-2016

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 5 General Requirements
  • 6 Technical Requirements
  • 6.1 Marking
  • 6.1.1 Markings on lamps
  • 6.1.2 Product Information
  • 6.2 Energy Saving Evaluation
  • 6.15 Durability
  • 7 Test Methods
  • 7.1 Inspection of lamp markings
  • 7.2 Energy-saving evaluation and inspection
  • 7.5 Light Output
  • 7.14 Durability Test

5 General Requirements

5.1 The luminaires shall comply with the requirements of Chapter 4 and

5.6 of GB/T 31897.1-2025.

5.2 The luminaires shall be able to function properly under the claimed conditions.

5.3 The safety of luminaires shall comply with the provisions of GB 7000.203.

5.4 The electromagnetic compatibility of luminaires shall comply with the provisions of GB/T 17743, GB 17625.1 and GB/T 18595.

5.5 The safety and performance of the light source and components supplied with the luminaire shall comply with the requirements of their applicable national standards.

5.6 To meet the requirements of this document, the specified sample size must satisfy all requirements.

6.1.1 Markings on lamps

6.1.1.1 The following electrical parameters shall be marked.

---Rated power supply voltage;

---Rated input power;

---Rated standby power (if applicable).

6.1.1.2 The following photometric parameters should be labeled.

---Rated luminous flux of the luminaire;

---Luminous efficiency of lamps.

6.1.1.3 For luminaires with adjustable LED module positions, the adjustment position should be clearly marked near the adjustment device.

6.1.1.4 For luminaires with adjustable elevation angles, the adjustment angle should be marked on the adjustment device.

6.1.1.5 For luminaires with asymmetrical longitudinal light distribution along the road, the housing shall be marked with markings and text descriptions indicating that the luminaire is installed along the direction of vehicle travel.

Note. For an introduction to symmetrical and asymmetrical lighting for tunnel lighting fixtures, please refer to Appendix C.

6.1.2 Product Information

6.1.2.1 The product sample book or instruction manual shall include at least the contents specified in

6.1.2.2 to 6.1.2.12.

6.1.2.2 The information specified in Table 1, Chapter 4 of GB/T 31897.201-2025, including numbers b and f~l, shall be indicated, including.

---Photometric code;

---Light flux maintenance code;

---Initial and maintained rated chromaticity coordinate values;

---Rated correlated color temperature (CCT, K);

---Rated general color rendering index (Ra);

---Rated ambient temperature (tq) related to luminaire performance;

---Rated luminous efficacy (lm/W);

---Refining time, if not 0h.

6.1.2.3 The applicable control device model and specifications and its corresponding manufacturer shall be indicated.

6.1.2.4 The applicable LED module model and specifications and its corresponding manufacturer should be indicated.

6.1.2.5 For luminaires with replaceable LED modules, the replacement method should be explained. If bolts are used for fixing, the tightening method should be indicated in the instruction manual. The system displays the torque value and provides a warning that "LED module replacement requires professional personnel."

6.2 Energy Saving Evaluation

6.2.1 General Rules It should meet the manufacturer's claimed applicable luminance and uniformity in the middle segment, and satisfy the standard limits for threshold increments. Requirements for lighting power density. The conformity is checked by

6.2.2 and 6.2.3.

6.2.2 Tunnel Lighting Quality The average road surface light intensity should be calculated based on the measured spatial photometric distribution data of the luminaires and the luminaire installation conditions claimed in the manufacturer's instructions. Brightness maintenance value, overall road surface brightness uniformity, road surface longitudinal brightness uniformity, and initial value of threshold increment. Note

1.The purpose of this clause is to provide an estimate of the quality of tunnel lighting provided by the luminaires. Due to the significant differences in the reflectivity of the wall materials actually used in tunnels, the quality of tunnel lighting provided by the luminaires may vary. Because accurate prediction is difficult during the design phase, the method provided in this document ignores the contribution of wall reflections to road surface brightness when calculating tunnel lighting quality. When the contribution of on-site wall reflection to road surface brightness is very low, the calculated value is basically consistent with the on-site measured value. When the contribution of on-site wall reflection to road surface brightness is very low, the calculated value is basically consistent with the on-site measured value. When the contribution to brightness is high, the evaluation according to this document may be more severe, such as the calculated brightness value being lower than the actual measured value, or the TI value being higher than the actual measured value. The lighting quality in the middle section of the tunnel should meet the following requirements.

---Under the same installation conditions, the average brightness of the road surface should not be lower than the applicable brightness claimed by the manufacturer.

---Under the same installation conditions, the overall uniformity of road surface brightness and the longitudinal uniformity of road surface brightness should not be lower than the brightness uniformity claimed by the manufacturer. Uniformity.

---The initial value of the threshold increment should not exceed 15%. Note

2.The lighting in other areas such as the entrance section, transition section, and exit section is related to the brightness of the opening.

6.2.3 Lighting power density The power density value of tunnel pavement lighting should not exceed the value specified in Table 3.

6.11 Weight The weight of a single luminaire (including bracket and controller) should not exceed 15kg, but should not exceed 20kg.

6.12 Operating ambient temperature It should be able to work normally under conditions of -40°C to 45°C. If the ambient temperature of the area where the product is used exceeds the above-mentioned range, it should be able to operate normally at the marked limit temperature.

6.13 Luminous flux maintenance Luminaires using LED modules that demonstrate compliance with GB/T 24823-2024 (see 4.2) do not need to provide samples for this test. Module sound The maintenance value at the rated value tp can be claimed as the maintenance value of the luminaire at tq. Luminaires using LED modules that do not explicitly state compliance with GB/T 24823-2024 shall be tested for a period equal to the rated life. 25%, with a maximum of 6000 hours. In addition to the requirements below, the provisions of

11.2 in GB/T 24823-2024 also apply to LED luminaires. The ambient temperature for maintaining the test should be within the performance temperature range (rated tq ± 5°C). The measured luminous flux should not be less than the luminous flux corresponding to the rated luminous flux maintenance rate.

6.14 Correlated color temperature, chromaticity coordinates, and color rendering index

6.15 Durability

6.15.1 Temperature Cycling It should comply with the requirements of Chapter 5 of GB/T 33721-2026.

6.15.2 Power Switch It should comply with the requirements of Chapter 6 of GB/T 33721-2026.

6.15.3 Accelerate service life It should comply with the requirements of Chapter 7 of GB/T 33721-2026.

6.16 Vibration It should comply with the requirements of Chapter 13 of GB/T 33721-2026.

6.17 Performance rating of luminaires Lighting fixtures should be classified into Grade A, Grade B, or Grade C according to their performance level. The relevant requirements for Grade A, Grade B, or Grade C shall comply with the provisions of Table 4.

7.1 Inspection of lamp markings

7.1.1 Markings on lamps The marking test shall be conducted according to the method specified in

3.4 of GB/T 7000.1-2023.The marking content shall be visually inspected.

7.1.2 Inspection of product information requirements Visual inspection of the product information content.

7.2 Energy-saving evaluation and inspection

7.2.1 Measure the photometric distribution data of the luminaires and calculate the quality level of road lighting provided by the luminaires. Measure the photometric distribution data of the luminaires according to the provisions of GB/T 9468. Based on the measured photometric distribution parameters of the luminaire and the installation conditions given in the manufacturer's instructions, in accordance with GB/T 24827-2026 The average road surface brightness maintenance value, overall road surface brightness uniformity, and longitudinal road surface brightness uniformity calculated in Appendix D are in accordance with Appendix E of this document. The initial value of the threshold increment is calculated.

Note. The maintenance factor is determined according to the following method.

0.35 is suitable for situations involving improper materials and maintenance;

0.50 is suitable for ordinary materials and maintenance situations;

0.70 is suitable for situations requiring meticulous maintenance and high-quality materials;

--- Higher or lower values depend on the maintenance plan and material condition.

7.2.2 Calculate lighting power density The power at the input terminal of the luminaire, measured under the luminous intensity distribution test value within the rated voltage or rated voltage range, is expressed in watts (W). Based on the measured luminaire input power and the luminaire arrangement meeting the lighting quality conditions, calculations are performed according to Appendix F of GB/T 24827-2026. Calculate the lighting power density of the lamps.

7.3 Input Power and Power Factor Measurements should be taken at the power supply terminal of the luminaire if it has a manufacturer-specified control device (if required). Or, if a remote control device is used, Measured at the power supply terminal of the control device.

7.4 Standby Power The luminaire is powered on at its rated power. The input power of the luminaire is measured when it is in sleep mode (no light output).

7.5 Light Output

7.5.1 Luminous flux Measurements should be performed in accordance with the requirements of GB/T 9468.

7.5.2 Light Intensity Distribution The test shall be conducted according to the comparison method specified in Appendix B of GB/T 31897.1-2025.

Note. Appendix A of GB/T 31897.1-2025 specifies regional standard information for acceptable photometric data formats.

7.6 Luminous efficacy of luminaires The luminous efficacy of an LED lamp should be calculated by dividing the measured initial luminous flux of the LED lamp by the measured initial input power.

7.7 Dimming Adjust the luminous flux of the lamp from high to low according to the dimming control method claimed by the manufacturer, and monitor the light output of the lamp during the adjustment process. The output should vary continuously, ranging from 30% (or the minimum of the claimed dimming range) to 100%, or as claimed by the manufacturer.

7.8 Dustproof, protection against solid foreign objects, and waterproof Visually inspect the enclosure protection rating marked on the luminaire, and if necessary, test it according to the test methods specified in Chapter 9 of GB/T 7000.1-2023. Its qualification.

Note. The example that needs to be tested is when the IP rating verified in the safety inspection report of the lighting fixture is not IP65.

7.9 Types of corrosion protection for lighting fixtures The test should be conducted in accordance with the requirements of JB/T 9535.

7.10 Weight Weigh the lamps using standard weighing equipment.

7.11 Operating ambient temperature The compliance of the working environment temperature shall be tested in accordance with the following provisions.

---The lamps are placed in a constant temperature chamber, and a photometer is fixed at a specific position outside the chamber.

---The lamps were first turned on at an ambient temperature of 25°C until a stable light output was achieved. The relative luminous intensity value in a certain direction was then measured as the initial value. Initial value.

---After the temperature was kept constant at 45°C (or higher) and -40°C (or lower) for 2 hours, the relative [temperatures] in the same direction were [measured]. The ratio of the luminance value to the initial value should not be lower than the applicable luminance (see 6.1.2.7) and the average road surface luminance maintenance value (see 6.2.1). ratio.

7.12 Luminous flux maintenance The initial value of the tested optical output was set to 100%, which was used as the first data point to determine the lifetime. The optical output was measured for 6000 hours. For the second data point, the percentage of 6000h luminous flux to the initial value should not be less than the rated luminous flux maintenance rate. The method of applying ANSI/IESLM-80 data to luminous flux maintenance shall be performed in accordance with the requirements of Appendix C of GB/T 24823-2024.

7.14 Durability Test

7.14.1 Temperature Cycling Test The test shall be conducted in accordance with the requirements of Chapter 5 of GB/T 33721-2026.

7.14.2 Power switch test The test shall be conducted in accordance with the requirements of Chapter 6 of GB/T 33721-2026.

7.14.3 Accelerated service life test The test shall be conducted in accordance with the requirements of Chapter 7 of GB/T 33721-2026.

7.15 Vibration Test The test shall be conducted in accordance with the requirements of Chapter 13 of GB/T 33721-2026.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 44 pages — is available in the English PDF.

Editions of GB/T 32481

EditionTitleRevisionStatus
GB/T 32481-2026Performance specifications for LED luminaires for tunnel lightingcurrent editionCurrent
GB/T 32481-2016Performance specifications for LED luminaires for tunnel lightingprevious editionIn force until 1 November 2026

This page sells the current edition, GB/T 32481-2026. Earlier editions are listed for reference only.

How to Buy GB/T 32481-2026

  1. 1Add to cart. Click the "Buy GB/T 32481-2026" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
44 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32481-2026

$425.00

$360.00for partners