Valid

GB/T 32281-2015Test method for measuring oxygen, carbon, boron and phosphorus in solar silicon wafers and feedstock by secondary ion mass spectrometry (English PDF)

太阳能级硅片和硅料中氧、碳、硼和磷量的测定 二次离子质谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32281-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 10, 2015

Implementation date

January 1, 2017

Scope

GB/T 32281-2015 is the English-translated version of 太阳能级硅片和硅料中氧、碳、硼和磷量的测定 二次离子质谱法.

GB/T 32281-2015 is the Chinese standard "Test method for measuring oxygen, carbon, boron and phosphorus in solar silicon wafers and feedstock by secondary ion mass spectrometry".

Its scope clause reads: This standard specifies the secondary ion mass spectrometry (SIMS) method for the determination of oxygen, carbon, boron and phosphorus elements in solar grade silicon and silicon materials.

This standard applies to the detection of the element body content does not vary with the depth, and does not take into account the compensation of solar-grade single crystal or polysilicon or silicon The oxygen content of oxygen, carbon, boron and phosphorus.

The detection limit of each element body content is 0.2% (ie < 1 × 1020 atoms/cm3), detection The lower limit is oxygen content >= 5 × 1016atoms/cm3, carbon content >= 1 × 1016 atoms/cm3, boron content >= 1 × 1014 atoms/cm3 and Phosphorus content >= 2 × 1014 atoms/cm3.

The determination of the four elements can be carried out using a SIMS instrument equipped with a cesium primary ion source carry out. Its clauses include normative reference documents; terms and definitions; method summary.

Found what you need?

Document preview — GB/T 32281-2015

National Standard of the People's Republic of China

ICS
77.040.30
Classification
H 17

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 normative reference documents
  • 3 terms and definitions
  • 4 method summary

1 Scope

This standard specifies the secondary ion mass spectrometry (SIMS) method for the determination of oxygen, carbon, boron and phosphorus elements in solar grade silicon and silicon materials.

This standard applies to the detection of the element body content does not vary with the depth, and does not take into account the compensation of solar-grade single crystal or polysilicon or silicon

The oxygen content of oxygen, carbon, boron and phosphorus. The detection limit of each element body content is 0.2% (ie < 1 × 1020 atoms/cm3), detection

The lower limit is oxygen content >= 5 × 1016atoms/cm3, carbon content >= 1 × 1016 atoms/cm3, boron content >= 1 × 1014 atoms/cm3 and

Phosphorus content >= 2 × 1014 atoms/cm3. The determination of the four elements can be carried out using a SIMS instrument equipped with a cesium primary ion source carry out.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article

Pieces. For undated references, the latest edition (including all modifications) applies to this document.

GB/T 2828.1 Sampling inspection procedures Part 1. Batch inspection sampling plan for retrieval by quality limit (AQL)

GB/T 14264 terminology for semiconductor materials

ASTME673 terminology for surface analysis (Terminologyrelatingtosurfaceanalysis)

3 terms and definitions

The terms and definitions defined in GB/T 14264 and ASTME673 apply to this document.

4 method summary

4.1

A polysilicon or silicon single crystal sample (one or more standard and test samples) with a flat analytical surface after mechanical polishing is loaded

Sample rack. The sample rack was baked in air at 100 ° C for 1 h and sent to the SIMS instrument.

4.2

The surface of the standard sample was bombarded with cesium (Cs) primary ion beam to analyze the negative ion spectra of 16O, 12C, 11B28Si and 31P,

Carbon, boron and phosphorus relative sensitivity factor (RSF).

4.3

To reduce the oxygen and carbon background content of the instrument, all the samples in the sample rack were pre-sputtered with cesium primary ion beam, and the secondary ion strength was not analyze. The length of the pre-sputtering time depends on the instrument and the required oxygen and carbon background content.

4.4

with the cesium primary ion beam at two different sputtering rate bombardment of each sample the same measurement area, by reducing the beam grating area adjustment

Secondary sputtering rate.

4.5

In order to achieve optimum test capability, the two sputtering rates and the sputtering measurement time depend on the instrument used. Usually, the second one

The sputtering rate is at the maximum sputtering rate of the instrument and the first sputtering rate is less than one-half the second sputtering rate.

4.6

Negative secondary ions 16O, 12C, 11B28Si and 31P After mass spectrometer mass analysis, by electron multiplier (EM) or the same high sensitivity

Of the ion detector detection, the secondary ion counting strength is a function of time. The negative secondary ion count rate of silicon matrix elements (eg 28Si) is determined by

Faraday Cup (FC) or other suitable detectors. If multiple detectors are used during the test, the standard ion letter should be passed (Counting rate of the same negative secondary ion, or the counting rate of two negative ions of known relative intensity, such as the usual 28Si/30Si) […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 32281-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32281-2015

$135.00