Valid

GB/T 31723.411-2018Metallic communication cable test methods -- Part 4-11: Electromagnetic compatibility (EMC) -- Coupling attenuation or screening attenuation of patch cords, coaxial cable assemblies, pre-connectorized cables -- Absorbing clamp method (English PDF)

金属通信电缆试验方法 第4-11部分:电磁兼容 跳线、同轴电缆组件、接连接器电缆的耦合衰减或屏蔽衰减 吸收钳法

Preview PDF

This is a limited preview

Buy now to download the full PDF (24 pages)

Need quotation for your management?

Get a formal quotation for GB/T 31723.411-2018 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

September 17, 2018

Implementation date

January 1, 2019

Scope

GB/T 31723.411-2018 is the English-translated version of 金属通信电缆试验方法 第4-11部分:电磁兼容 跳线、同轴电缆组件、接连接器电缆的耦合衰减或屏蔽衰减 吸收钳法.

GB/T 31723.411-2018 — This part of GB/T 31723 specifies jumpers, coaxial cable assemblies, connectors for use in analog and digital communication systems. Test method for coupling attenuation and shielding attenuation of cables.

Found what you need?

Document preview — GB/T 31723.411-2018

National Standard of the People's Republic of China

ICS
33.120.10
Classification
L 26

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Test methods
  • 4.1 Equipment

Foreword

The electromagnetic compatibility part of GB/T 31723 "Metal Communication Cable Test Method" has been or is planned to release the following parts.

--- Part 4-0. Recommended limits for the relationship between electromagnetic compatibility surface transfer impedance and shielding attenuation;

--- Section 4-1. Introduction to electromagnetic compatibility shielding measurements;

--- Part 4-2. Electromagnetic compatibility shielding and coupling attenuation injection clamp method;

--- Part 4-3. Electromagnetic compatibility surface transfer impedance triaxial method;

--- Part 4-4. Shielding attenuation measurement method for electromagnetic compatibility shielding attenuation up to 3 GHz and above;

---Part 4-5. Electromagnetic compatibility coupling or shielded attenuation absorption clamp method;

---Part 4-6. Electromagnetic compatibility surface transfer impedance line injection method;

--- Part 4-7. Electromagnetic compatibility transfer impedance, shielding or coupling attenuation tube tube method;

---Part 4-8. Electromagnetic compatibility capacitive coupling admittance;

--- Part 4-9. Coupling attenuation triaxial method for electromagnetic compatibility shielded symmetrical cables;

---Part 4-10. Electromagnetic compatibility feedthrough and electromagnetic gasket shielding attenuation double coaxial method;

---Parts 4-11. Coupling attenuation or shielding attenuation absorption of electromagnetic compatibility jumpers, coaxial cable assemblies, connector cables

Clamp method

--- Part 4-12. Coupling attenuation or shielded attenuation absorption clamp method for electromagnetic compatibility connection hardware;

--- Part 4-13. Coupling attenuation absorbing clamp method for electromagnetic compatibility links and channels (laboratory conditions);

--- Part 4-14. Coupling attenuation absorbing clamp method for electromagnetic compatibility cable assemblies (field conditions).

This part is part 4-11 of GB/T 31723.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

This part uses the translation method equivalent to IEC 62153-4-11.2009 "Metal communication cable test method Part 4-11. Electromagnetic

Capacitor jumper, coaxial cable assembly, coupling attenuation of the connector cable or shielded attenuation absorption clamp method.

The documents of our country that have a consistent correspondence with the international documents referenced in this part are.

Coaxial communication cables - Part 1 . General rules, definitions and requirements (IEC 61196-1.

2005, IDT).

1 Scope

This part of GB/T 31723 specifies jumpers, coaxial cable assemblies, connectors for use in analog and digital communication systems.

Test method for coupling attenuation and shielding attenuation of cables.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 31723.405-2015 Test methods for metallic communication cables - Part 4-5. Electromagnetic compatibility coupling or s

Clamping method (IEC 62153-4-5.2006, IDT)

IEC 60050-726 International Electrotechnical Dictionary Part 726. Transmission Lines and Waveguides [International ElectrotechnicalVocab-

Uryy(IEV)-Part 726.Transmissionlinesandwaveguides]

IEC 61196-1 coaxial communication cables - Part 1. General specification, definitions and requirements (Coaxialcommunicationca-

bles-Part 1. Genericspecification-General, definitionsandrequirments)

ITU-TG.117.1996 Earthquake imbalance transmission (Transmissionaspectsofunbalanceaboutearth)

ITU-TO.9.1999 Assessment of test configurations for ground imbalances (Measuringarrangementstoassessthedegree

Ofunbalanceaboutearth)

3 Terms and definitions

The terms and definitions defined in IEC 61196-1 and IEC 60050-726 apply to this section.

The measured line (jumper, coaxial cable assembly, connector cable) in this section is referred to as "jumper" for short.

4 Test methods

4.1 Equipment

4.1.1 General

See 5.1.1 of GB/T 31723.405-2015 and Figure 1 of this part.

For the jumper test, two test sockets for the hardware module and extension cable are required to measure the jumper (see 4.1.3). These two tests

The ports are called the near-end test port and the far-end test port.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 31723.411-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
24 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 31723.411-2018

$205.00