Valid

GB/T 30793-2014Measuring ratio of anatase to rutile in titanium dioxide pigments by X-ray diffraction (English PDF)

X-射线衍射法测定二氧化钛颜料中锐钛型与金红石型比率

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 30793-2014 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 8, 2014

Implementation date

December 1, 2014

Scope

GB/T 30793-2014 is the English-translated version of X-射线衍射法测定二氧化钛颜料中锐钛型与金红石型比率.

GB/T 30793-2014 is the Chinese standard "Measuring ratio of anatase to rutile in titanium dioxide pigments by X-ray diffraction". Its scope clause reads: This standard specifies the method for the determination by X- ray diffraction of titanium dioxide pigment in anatase and rutile ratio.

This standard applies to the determination of titanium dioxide pigment in anatase and rutile ratio. The method may also be used containing titanium dioxide pigment The mixture, dry coating, liquid paint and powder coating.

A method of this standard apply to be free of interferences or interferences can be removed (see Appendix A) of any sample; B method is suitable for the sample In all phases of qualitative accurate, and that any data sample crystal structure of these phases can be obtained.

Found what you need?

Document preview — GB/T 30793-2014

National Standard of the People's Republic of China

ICS
87.060.10
Classification
G 53

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 4.1 X- ray diffractometer
  • 4.2 Test Conditions 1)

1 Scope

This standard specifies the method for the determination by X- ray diffraction of titanium dioxide pigment in anatase and rutile ratio.

This standard applies to the determination of titanium dioxide pigment in anatase and rutile ratio. The method may also be used containing titanium dioxide pigment

The mixture, dry coating, liquid paint and powder coating.

A method of this standard apply to be free of interferences or interferences can be removed (see Appendix A) of any sample; B method is suitable for the sample

In all phases of qualitative accurate, and that any data sample crystal structure of these phases can be obtained.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 3186 Paints, varnishes and raw materials for paints and varnishes - Sampling

Principle 3

3.1 A standard method using the intensity ratio method, as measured from anatase and maximum diffraction peak intensity with X- ray diffraction rutile will

Diffraction peak intensity of anatase is converted into rutile with respect to the content of anatase, rutile content is determined by the difference.

3.2

Standard B method using the Rietveld analysis lawful, that is based on the crystal structure and structural parameters of the model assumptions, combined with a

Species peak shape function to calculate the polycrystalline diffraction, adjust these structural parameters and peak shape parameters make computing spectrum consistent with the experimental determination of the spectrum obtained

Structural parameters and peak shape parameters, and thus the determination of titanium dioxide pigment in anatase and rutile ratio.

4 instruments and experimental conditions

4.1 X- ray diffractometer

Comprehensive diffractometer stability better than 1%.

NOTE. Integrated stability of this standard instrument refers to the same conditions on the same test the same diffraction surface of the sample, measured once every 10min diffraction intensity in

Diffraction line intensity values measured within 8h relative standard deviation sigma-1 (see YB/T 5320-2006).

4.2 Test Conditions 1)

4.2.1 High Voltage Power Supply

Signal intensity select X- ray tube voltage, current, and other conditions, so 0.1% is anatase produced at least four times the noise strength.

1) In the case to ensure accuracy, but also to choose the best test conditions depending on the X- ray diffraction performance and test sample of the actual situation.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 30793-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 30793-2014