GB/T 30654-2014Test method for lattice constant of III-nitride epitaxial layers (English PDF)
III族氮化物外延片晶格常数测试方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 30654-2014 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2014
Implementation date
September 1, 2015
Scope
GB/T 30654-2014 is the English-translated version of III族氮化物外延片晶格常数测试方法.
GB/T 30654-2014 is the Chinese standard "Test method for lattice constant of III-nitride epitaxial layers". Its scope clause reads: This standard specifies the use of high-resolution X-ray diffraction test III nitride epitaxial wafer lattice constant method.
This standard applies to the oxide substrate (Al2O3, ZnO, etc.) or epitaxial growth on the (GaN, Si, GaAs, SiC, etc.) of a semiconductor substrate Nitride (Ga, In, Al) N monolayer or multilayer heteroepitaxial sheet lattice constant measurements.
Other hetero epitaxial wafers measuring the lattice constant can be The reference standard. Its clauses include symbol; principle of the method.
Found what you need?
Document preview — GB/T 30654-2014
National Standard of the People's Republic of China
- ICS
- 77.040.20
- Classification
- H 21
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Symbol
- 3 PRINCIPLE OF THE METHOD
- 3.1 General
- 3.2 relative measurement method
1 Scope
This standard specifies the use of high-resolution X-ray diffraction test III nitride epitaxial wafer lattice constant method.
This standard applies to the oxide substrate (Al2O3, ZnO, etc.) or epitaxial growth on the (GaN, Si, GaAs, SiC, etc.) of a semiconductor substrate
Nitride (Ga, In, Al) N monolayer or multilayer heteroepitaxial sheet lattice constant measurements. Other hetero epitaxial wafers measuring the lattice constant can be
The reference standard.
2 Symbol
The following symbols apply to this document.
FWHM. full width at half peak height of the diffraction of the diffraction peak half the full width.
omega. the angle between the incident light and the surface of the sample.
2theta. the angle between the detector and the incident light.
chi axis. the tilt axis of the sample, and the sample surface intersected by the diffraction plane is made.
chi angle. the sample surface and the diffraction plane intersecting angle.
omega-2theta scan or 2theta-omega scan. linkage scan detector at twice the speed of scanning the sample.
thetaB. X-ray generator and the angle of incident light between the reflective surfaces when diffraction.
3 PRINCIPLE OF THE METHOD
3.1 General
III nitride semiconductor crystalline epitaxial wafer relatively good integrity, the use of high resolution lattice constant X-ray diffraction measurement sample
Not only easy, but also has high accuracy, no damage and no pollution. Methods of measurement of the lattice constant of the epitaxial wafer has two categories. the relative measurement
The amount and method of absolute measurement method.
3.2 relative measurement method
According to the epitaxial substrate, the peak position of the peak relative to the lattice constant of the epitaxial film is determined. In this measurement method, the form that the substrate does not occur
Change, in a fully relaxed state, and then use the double-crystal diffraction or 3-axis crystal diffraction omega-2theta scanning, whereby an epitaxial film diffraction peak and lining
Peak spacing bottom peak deltaomega. If the extension of the peak on the left side of the substrate peak, the epitaxial film is compressive strain state, deltaomega is negative; if the epitaxial substrate peak peak
The right side of the epitaxial film in the tensile strain state, deltaomega is positive. According to Bragg equation 2dsinthetaB = nlambda, to give the corresponding distance between the planes, namely
Formula (1).
de = sinthetas sin (thetas deltaomega) ds ... (1)
Where.
de --- spacing epitaxial film crystal face;
ds --- spacing of the substrate crystal face;
thetas --- Bragg angle of the substrate crystal planes.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 30654-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 30654-2014
$135.00