Valid

GB/T 30646-2014Determination of phthalate plasticizers content in coatings - Gas chromatography/mass spectrometry method (English PDF)

涂料中邻苯二甲酸酯含量的测定 气相色谱/质谱联用法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 30646-2014 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 31, 2014

Implementation date

July 1, 2015

Scope

GB/T 30646-2014 is the English-translated version of 涂料中邻苯二甲酸酯含量的测定 气相色谱/质谱联用法.

GB/T 30646-2014 is the Chinese standard "Determination of phthalate plasticizers content in coatings - Gas chromatography/mass spectrometry method". Its scope clause reads: This standard specifies the determination by gas chromatography/mass spectrometry coatings phthalate content.

This standard applies to the determination of paints and coatings raw materials in a variety of phthalate content.

Including but not limited to, include phthalic Carboxylic acid esters, such as dibutyl phthalate (DBP), phthalate, butyl benzyl phthalate (BBP), di-iso-octyl phthalate (DEHP), phthaloyl Acid dioctyl ester (DNOP), diisononyl phthalate (DINP), diisodecyl phthalate (DIDP), etc. Other types of phthalic Dicarboxylate can also be performed with reference to the present method. Its clauses include reagents and materials.

Found what you need?

Document preview — GB/T 30646-2014

National Standard of the People's Republic of China

ICS
87.040
Classification
G 50

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 4 Reagents and materials
  • 4.1 Carrier gas
  • 4.2 Dilution solvent
  • 4.3 Calibration compound
  • 4.4 standard stock solution
  • 4.5 mixed standard working solution
  • 5.2 Injector

1 Scope

This standard specifies the determination by gas chromatography/mass spectrometry coatings phthalate content.

This standard applies to the determination of paints and coatings raw materials in a variety of phthalate content. Including but not limited to, include phthalic

Carboxylic acid esters, such as dibutyl phthalate (DBP), phthalate, butyl benzyl phthalate (BBP), di-iso-octyl phthalate (DEHP), phthaloyl

Acid dioctyl ester (DNOP), diisononyl phthalate (DINP), diisodecyl phthalate (DIDP), etc. Other types of phthalic

Dicarboxylate can also be performed with reference to the present method.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 3186 Paints, varnishes and raw materials for paints and varnishes - Sampling

Principle 3

Methyl ethyl ketone solvent sample phthalates ultrasonic extraction. After the volume of extract by gas chromatography/mass spectrometry (GC/MS) assay. With full scan total ion chromatogram (TIC) and mass spectra (MS) qualitative and selected ion monitoring (SIM) and

Quantitative external standard method.

4 Reagents and materials

4.1 Carrier gas

helium, purity >=99.999%.

4.2 Dilution solvent

methyl ethyl ketone, purity >=98% (mass fraction) or known purity.

4.3 Calibration compound

dibutyl phthalate (DBP), phthalate, butyl benzyl phthalate (BBP), di-iso-octyl phthalate (DEHP),

Octyl phthalate (DNOP), diisononyl phthalate (DINP), diisodecyl phthalate (DIDP), purity >=98% (Mass fraction) or known purity.

4.4 standard stock solution

namely, accurately weighed amount of phthalates calibration compound (4.3) to prepare a concentration of methyl ethyl ketone (4.2) as

5000mg/L of standard stock solution.

4.5 mixed standard working solution

using serial dilution method, standard stock solution was diluted with methyl ethyl ketone (4.2) (4.4) to a concentration suitable for mixing

Standard working solution.

NOTE. The standard solution stored in the dark below 4 °C, standard stock solution is valid for six months, working standard solution is valid for three months.

5. Apparatus 5.1 Gas chromatography/mass spectrometry.

5.2 Injector

capacity should be at least twice the amount of injection.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 30646-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 30646-2014