Valid

GB/T 30172-2013Synchronous belt drives—Technical specification for installation (English PDF)

同步带传动 安装技术规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 30172-2013 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 17, 2013

Implementation date

October 1, 2014

Scope

GB/T 30172-2013 is the English-translated version of 同步带传动 安装技术规范.

GB/T 30172-2013 sets out how a synchronous belt drive is to be installed.

Clause 1 states that it specifies the terms and definitions of the belt drive system, the transmission structure, the requirements for the system components, the installation requirements and the test items to be made before the drive system is run, and that it applies to general industrial timing belts; no exclusion is stated.

The standard has no normative references clause: clause 2 is Terms and definitions, and it defines two terms of its own, the total eccentricity, the sum of the errors that the working parts of the drive, namely shafts, bushings, bearings, pulleys and belt, contribute through their own errors and through assembly errors, and the belt strain, the change in the total length of the timing belt pitch line caused by the eccentricity, in wording the draft garbles.

Clause 3, Transmission constitution, states that the belt drive system is made up of pulleys, belts and shafting, with a tension wheel added where necessary, and clause 4, whose heading the draft garbles, covers the parts of the system in 4.1 pulley collar, which says which sides of which pulleys need retaining rings in horizontal, vertical and multi-axis drives and when the centre distance exceeds eight times the small pulley diameter, and 4.2 tensioner, which gives the two cases in which a tensioner may be used.

Clause 5, Installation requirements, runs from 5.1 pulley installation requirements, where the two pulley axes are to be parallel and their width centre planes coincident and Table 1 gives the allowable value of the skew tangent tan(theta)m by belt width, through 5.2 on the eccentricity of the system, with Table 2 giving belt strain ranges and formulas (1) and (2) for the strain and for the total eccentricity as a sum of pulley, bore, bearing and belt terms, and 5.3 on belt tensioning, where the degree of tension is checked by applying the force G of Tables 3 to 6 at the midpoint of the span between the two pulleys and comparing the deflection with the value from formula (3), to 5.4 on the tensioner, which distinguishes inside from outside installation and gives in Tables 7 to 9 the smallest pulley tooth numbers and pitch diameters by belt model and small pulley speed.

Clause 6, transmission test items before operation, has the drive commissioned for 10 min and then the items of Table 10 examined, namely belt climbing on the pulley ribs, resonance or noise, tooth jumping and an abnormal drop in tension, with inspection and adjustment made only after the belt drive has stopped completely and the power has been cut off.

The page closes with a list of references holding GB/T 11361-1989, GB/T 11362-2008, GB/T 17119-1997 and GB/T 24619-2009.

It was proposed by China Machinery Industry Federation and is kept by the National Standardization Technical Committee of the pulley and the belt (SAC/TC428), under ICS 21.220.10 and Chinese classification J18, with about 12,171 words estimated.

It was issued on 17 December 2013 and has applied since 1 October 2014; the page does not say which edition it replaces.

Found what you need?

Document preview — GB/T 30172-2013

National Standard of the People's Republic of China

ICS
21.220.10
Classification
J 18

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Terms and definitions
  • 3 Transmission constitution
  • 5 Installation requirements
  • 6 Transmission test items before operation
  • 4 Belt tension abnormal decline

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Machinery Industry Federation.

1 Scope

This standard specifies the terms and definitions of the belt drive system, transmission structure, the requirements of the system components, installation requirements and drivetrain Test items before running the system.

This standard applies to general industrial timing belt.

2 Terms and definitions

The following terms and definitions apply to this document.

2.1 The total eccentricity

By its own errors and assembly errors synchronous belt drive systems work together in the transmission parts (shafts, bushings, bearings, pulleys, belt) due Error sum.

2.2 With strain

Since the amount of change in the total length of the timing belt pitch line unit on the eccentricity caused.

3 Transmission constitution

Belt drive system consists of pulleys, belts and shafting, etc., as necessary, to increase the tension wheel.

4 Requirements of the system components

4.1 Pulley collar

According to the following selection pulley Collar.

--- In the second horizontal drive shaft, the pulley should be at least two wheels on both sides of a collar or a different one on each side of the two pulleys Dang Quan;

--- Vertical shaft drive, the sides of which a pulley should ring, while the other pulley system is only one side at the bottom of the retaining ring;

--- When the center distance of more than eight times the diameter of the small pulley, the two sides should have the pulley retainer;

--- Multi-axis drive, you should make sure that every one pulley with two or collar around the pulley system on each side have a collar.

4.2 Tensioner

Tensioner may use in the following cases.

--- When the center distance can not be adjusted, as a method of belt tension;

--- Larger transmission ratio, increasing the wrap angle small pulley.

5 Installation requirements

5.1 Pulley installation requirements

In the horizontal drive, the pulley when installed, so that the two should be parallel to the axis of the pulley, two wide center plane coincide (see Figure 1), the tangent of the skew angle Tanthetam values should be consistent with Table 1.

5.2 System Requirements eccentric

When the system is running, since the total eccentricity of the belt tension fluctuation generation cycle work, if volatility is superimposed on the work load, the total load can be Can exceed the fatigue limit device, resulting in adverse effects on the whole, lead to early fatigue band. Thus, the total eccentricity respond effectively Comment Estimated, usually by size with strain assessed with strain range shown in Table 2, and calculate the total eccentricity with strain formulas see equation (1) and (2).

If it is confirmed with the strain is too great and should be reduced by each belt drive transmission components (shafts, bushings, bearings, pulleys, belt) and self-loading error Hotels error to reduce the overall eccentricity of the actuator.

epsilon b = [(Et x 2)/l] x 100% (1)

Where. epsilon b --- with strain; Et --- total eccentricity in millimeters (mm); l --- belt length, in millimeters (mm).

Et = (Ea1 Ea2) (Eb1 Eb2) (Ec1 Ec2) Ed (2)

Where. Ea1 --- drive pulley and eccentricity sleeve millimeters (mm); Ea2 --- driven pulley and eccentricity sleeve millimeters (mm); --- Eb1 could drive pulley shaft diameter of the maximum pore diameter and the smallest difference in millimeters (mm); --- EB2 driven pulley shaft diameter of the maximum pore diameter and the smallest difference in millimeters (mm); Ec1 --- drive shaft and the eccentricity of the bearing (attached to the outer diameter of the drive shaft bearing on the total runout), millimeters (mm); Ec2 --- driven shaft and the eccentricity of the bearing (mounted on the driven shaft diameter bearing on the total runout), millimeters (mm); Ed --- with eccentricity (center distance change measured with a long time), millimeters (mm).

5.3 Requirements belt tensioning

After a properly installed with tension. Tension is too small, there are frequent starting at impact load, prone to tooth skipping phenomenon;

Tension is too large, it will reduce the life of the belt.

Belt tension by changing the gear center distance or increase the tension pulley to achieve. Its degree of tension can be applied between the two pulleys span midpoint Mounting force applied to test, see Figure 2, Table 3 to Table 6 is applied to the predetermined attachment force G, adjust the center (3) so that a calculated value from the formula and the deflection f Consistent. Explanation.

Deflection f --- tangent at the midpoint generated in millimeters (mm); T --- tangent length, in millimeters (mm);

--- A center distance in millimeters (mm); G --- with mounting force, expressed in Newtons (N).

f = 0.016t (3)

Where. t = a2- (d2-d1) 2/4; D1 --- small pulley pitch diameter in millimeters (mm); D2 --- large pulley pitch diameter in millimeters (mm).

5.4 Requirements tensioner

According to the role of the tension pulley, the following two installation methods.

a) the internal mounting With belt tensioners. Tensioner should adopt the same toothed belt round the number of teeth tensioner pulley should generally be greater than the number of teeth with a little (see Tables 7 to 9), in order to avoid reducing the number of teeth, should the tension wheel mounted on the side of the loose side, see Fig. 3a).

b) installation outside of With pulley wrap angle increases. Tensioner can be raised without intermediate flat pulley with a diameter of a few with the most number of teeth of the pulley pitch diameter (See Table 7 to Table 9), mounted on the loose side, the belt will not have too much bending, see Figure 3b).

a) the inside of the installation b) installation outside of Figure 3 tensioner installation

6 Transmission test items before operation

After transmission commissioning 10min, should examine the items listed in Table 10, inspection and adjustment should ensure that the belt drive is completely stopped, cut off Power before.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 30172-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 30172-2013

$195.00