Valid

GB/T 2985-2008Biological microscope (English PDF)

生物显微镜

Preview PDF

This is a limited preview

Buy now to download the full PDF (27 pages)

Need quotation for your management?

Get a formal quotation for GB/T 2985-2008 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 28, 2008

Implementation date

February 1, 2009

Scope

GB/T 2985-2008 is the English-translated version of 生物显微镜.

GB/T 2985-2008 specifies the classification, basic parameters, requirements, test methods, inspection rules and the marking, packaging, storage and transportation of biological microscope products.

Clause 1 states that it applies to the various types of biological microscope observed in visible light with a mechanical tube length of 160 mm or infinite, and to the various types that adopt photography and video technology to perform image viewing and processing; the clause records no exclusion.

The table of contents gives seven clauses: 1 Scope, 2 Normative references, 3 Classification and basic parameters, 4 Requirements, 5 Test methods, 6 Inspection rules and 7 Marking, packaging, transportation and storage, with the requirements running from page 7 and the test methods from page 13 to page 26, so those two clauses carry most of the text.

Clause 2 cites GB/T 2609, GB/T 2828.1, GB/T 9246, GB/T 9247, GB/T 15464, GB/T 22055.1, GB/T 22056 and GB/T 22057.1.

The part of clause 4 printed on the page sets the optical and mechanical limits item by item: a permissible difference of magnification of not more than plus or minus 5 per cent for objectives and for eyepieces, an image centre displacement of not more than 0.6 mm when a tilting eyepieces sleeve is turned through 360 degrees, a condenser whose top stands 0.03 mm to 0.4 mm below the surface of the stage at its highest position, requirements for dark field condensers and for the sealing of immersion condensers, 4.17 on binocular system performance with its limits on magnification difference, light and dark difference, field azimuth difference, centre deviation and beam parallelism over a pupil distance of 55 mm to 75 mm, 4.18 on photography and video system performance, and 4.19 on electrical safety performance.

Several requirements are graded by class of instrument, the universal, laboratory and research microscope, as in 4.18.2, where the cleaning scope of the photography and video field must be not less than 45, 60 and 75 per cent respectively.

The foreword records what changed from the previous edition: performance requirements and test methods for the photography and video system were added, the electrical safety performance requirements were developed according to GB 4793.1-2007 and given test methods, four indicators previously left to other standards were given specific values, the mechanical tube length of the universal microscope was changed to 160 mm or infinite, the magnification tolerance of objectives and eyepieces became plus or minus 5 per cent, the SY-1 and SY-2 test slides were deleted, the 600 lines/mm grid grating was changed to a 600 lines/mm grating, and the sampling plan for type inspection was deleted from the inspection rules.

It replaces GB/T 2985-1999, was issued on 28 July 2008 and has applied since 1 February 2009, and the foreword lists GB 2985-1982, GB 2985-1991 and GB/T 2985-1999 as the previous versions it replaces; it carries ICS 37.020 and Chinese classification N 32.

Found what you need?

Document preview — GB/T 2985-2008

National Standard of the People's Republic of China

ICS
37.020
Classification
N 32
Replacing
GB/T 2985-1999

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Classification and basic parameters6
  • 4 Requirements7
  • 5 Test methods13
  • 6 Inspection rules26
  • 7 Marking, packaging, transportation and storage27

Foreword

This Standard replaces GB/T 2985-1999 Biological Microscope. Main differences between this Standard and GB/T 2985-1999 are.

- Add performance requirements of photography and video system. And provide the corresponding test methods.

- Electrical Safety Performance Requirements are developed according to the relevant requirements of GB 4793.1-2007 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 1: General Requirements. The test methods are also specified correspondingly.

- The requirements to four technical indicators - "objectives aberration correction and clear vision", "requirements for condenser", "revolving nosepiece positioning error" and "fine tuning mechanism backlash" in the previous version are changed from "reference to other relevant standards" to "specific indicator requirements".

- The mechanical tube length of universal microscope was modified to 160 mm or infinite.

- The fit dimension of eyepieces and objectives tube of the universal microscope is modified to phi23.2.

- The magnification tolerance of objectives and eyepieces of microscope is modified to ± 5%.

- There is no specific provisions for models of Test Tool SY-1 type bacterial inspection slide, and SY-2 type blood cell inspection slide. That is, delete SY-1 type and SY-2 type.

- Modify the Test Tool 600 lines/mm grid grating to 600 lines/mm grating.

- Delete the sampling plan of type inspection in inspection rules.

1 Scope

This Standard specifies the classification, basic parameters, requirements, test methods, inspection rules, marks, packaging, storage and transportation of biological microscope products.

This Standard applies to various types of biological microscopes, observed in visible light, with mechanical tube length of 160 mm or infinite.

This Standard applies to various types of biological microscopes (hereinafter referred to as the microscope) that adopt photography and video technology to perform the image viewing and processing.

2 Normative references

The articles contained in the following documents have become part of this Standard when they are quoted herein. For the dated documents so quoted, all the modifications (excluding corrections) or revisions made thereafter shall not be applicable to this Standard.

For the undated documents so quoted, the latest editions shall be applicable to this Standard.

GB/T 2609 Microscopes - Objectives

GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection (GB/T 2828.1-2003, IDT ISO 2859-1:1999)

GB/T 9246 Microscopes - Oculars (eyepieces)

GB/T 9247 Microscopes - Condensers

GB/T 15464 General-purpose specification for the packaging of instrumentation products

GB/T 22055.1 Microscopes - Screw threads for objectives and related nosepieces - Part 1: Screw thread type RMS (4/5inx1/36in) (GB/T 22055.1-2008, IDT ISO 8038-1:1997)

GB/T 22056 Microscopes - Marking of objectives and eyepieces (GB/T 22056-2008, MOD ISO 8578:1997)

GB/T 22057.1 Microscopes - Imaging distances related to mechanical reference planes

4 Requirements

4.11 The allowable difference of magnification of microscope objectives shall not exceed ± 5%.

4.12 The allowable difference of magnification of microscope eyepieces shall not exceed ± 5%.

4.13 For the microscope with tilting eyepieces sleeve, when the eyepieces sleeve rotates for 360°, the center displacement of the image on the eyepieces focal plane shall not be more than 0.6mm.

4.14 The optical axis of the lighting system and observation system shall be consistent; the lighting in the field shall be uniform, without the phenomenon of one light side and one dark side or light barring. When the condenser rises to the highest position, the top of the condenser shall be below the surface of the stage from 0.03mm to 0.4mm.

4.15 The dark field condenser shall be evenly illuminated. When there is no specimen placed on the stage, the dry type dark field condenser's field shall be basically dark; background of immersion type dark field condenser's field shall be relatively dark; specimen under observation shall be clear and sufficiently bright.

4.16 There shall be reliable sealing measures for immersion bright field condenser and immersion dark field condenser.

4.17 Microscope binocular system performance

4.17.1 The difference of the magnification of two systems on the left and right sides of the binocular microscope shall comply with the following requirements.

a) When the field angle of the eyepieces does not exceed 50°, it is not more than 2.0%.

b) When the field angle of eyepieces exceed to 50°, it is not more than 1.5%.

4.17.2 The spectrum color of two systems on the left and right sides of the binocular microscope shall be basically same. The difference of the light and dark shall not be more than 18%.

4.17.3 The azimuth difference of the field image plane shall not more than 40' of the two systems on the left and right sides of the binocular microscope.

4.17.4 Within the scope of 55mm - 75mm of the binocular pupil distance, the center deviation of the left and right field shall comply with the following requirements.

a) Up and down. 0.2mm;

b) Right and left external sides. 0.2mm;

c) Right and left internal sides. 0.4mm.

4.17.5 Outgoing beam coming from the left and right of the binoculars sleeve shall be in the parallel condition. The measurement shall be conducted at any position within the scope of the pupil distance of 55-75mm. And the permissible deviation of parallel shall comply with the following requirements.

a) Divergence in the horizontal direction shall not be more than 60';

b) Convergence in the horizontal direction shall not be more than 30';

c) Intersection in the vertical direction shall not be more than 30'.

4.17.6 When the two systems on the left and right of the binoculars sleeve is in zero visibility, the high-low difference shall not be more than 1.5mm between end faces of two eyepieces sleeves.

4.18 Microscope photography and video system performance

4.18.1 The image observed by the eyepieces shall be synchronous with that observed on the display screen. And the object space focusing volume shall not exceed ± 0.05mm.

4.18.2 Cleaning scope of the photography, video field shall comply with the following requirements.

a) Universal microscope. Not less than 45%;

b) Laboratory microscope. Not less than 60%;

c) Research microscope. Not less than 75%.

4.18.3 The image center of the display screen field shall be basically consistent with that in the eyepieces field. And the maximum center offset shall not exceed one fifth of the diagonal of the display screen field.

4.18.4 The image orientation observed on the display screen shall be basically consistent with that observed by the eyepieces.

4.18.5 The field within the display screen shall be clean; with uniform brightness; and without shadows, spots, streak and various reflected light spot affecting the observation or flare phenomenon. […]

4.19 Electrical safety performance of the microscope

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 2985

EditionTitleRevisionStatus
GB/T 2985-2008Biological microscopecurrent editionCurrent
GB/T 2985-1999Biological microscopeprevious editionSuperseded

This page sells the current edition, GB/T 2985-2008. Earlier editions are listed for reference only.

How to Download GB/T 2985-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
27 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 2985-2008