GB/T 29739-2013Test method of resistance to repeat opening and closing for windows and doors (English PDF)
门窗反复启闭耐久性试验方法
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for GB/T 29739-2013 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
September 18, 2013
Implementation date
June 1, 2014
Scope
GB/T 29739-2013 is the English-translated version of 门窗反复启闭耐久性试验方法.
GB/T 29739-2013 — This standard specifies a certain number of times after the opening and closing cycle, open the door and test methods portion of the mechanical durability of the window.
This standard applies to normal operating conditions in a variety of materials and opening and closing the door jamb whole system and the whole window jamb.
The standard test relates to window and door frames, open the member (including all auxiliary member) and the necessary hardware accessories, including the opening and closing device. but not Including any additional fixing accessories, such as. plug, spreaders, nor any limit device installed separately.
The standard opening and closing cycle including motion hinges, struts, balancing devices and other mechanical devices and other auxiliary member.
Found what you need?
Document preview — GB/T 29739-2013
National Standard of the People's Republic of China
- ICS
- 91.060.50
- Classification
- P 32
Issued by: Standardization Administration of China
Contents
- Introduction
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Test principle
- 5 Test equipment
- 6 Test preparation
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses redrafted law revision using ISO 8274:2005 "Standard Test Method for opening and closing doors and repetition durability." this standard and ISO 8274:2005 and the difference compared to the following technical reasons. on normative references, with this standard GB/T 29048 instead of prEN12046-1.1996, with GB/T 29555 "Standard Test Method for opening and closing force of the door" instead prEN12046-2.
1999, in order to adapt to China's technical conditions.
This standard and ISO 8274:2005, compared the structure has been adjusted, specific adjustments are as follows.
--- ISO 8274:2005 Mount paragraph in Chapter 5 of this standard adjustment 5.1, 5.1 and 5.2 of the original is adjusted to 5.2 and 5.3;
--- ISO 8274:2005 Mount paragraph in Chapter 8 of the cancellation, the content is adjusted to 8.1 and 8.2 of this standard.
The standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China.
This standard by the national building curtain wall windows and doors Standardization Technical Committee (SAC/TC448) centralized.
Introduction
This standard test method provides information on the doors and windows mechanical durability, does not involve material or surface treatment layer corrosion or rust in the environment Corrosion durability.
Repeated opening and closing doors and endurance test methods
1 Scope
This standard specifies a certain number of times after the opening and closing cycle, open the door and test methods portion of the mechanical durability of the window.
This standard applies to normal operating conditions in a variety of materials and opening and closing the door jamb whole system and the whole window jamb.
The standard test relates to window and door frames, open the member (including all auxiliary member) and the necessary hardware accessories, including the opening and closing device. but not Including any additional fixing accessories, such as. plug, spreaders, nor any limit device installed separately.
The standard opening and closing cycle including motion hinges, struts, balancing devices and other mechanical devices and other auxiliary member.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
Hoisting force test method GB/T 29048 Window Hoisting force test method GB/T 29555 Door
3 Terms and Definitions
The following terms and definitions apply to this document.
Opening and closing cycle cycle Doors, sash opening and closing process of the full range of actions, including the locking device is released from the doors and windows, door and window fans fully open, closed, to re-locking device the new lock.
Opening and closing device operatingdevice for the user to manipulate doors, sash, and opening and closing movement of the device consists of hardware accessories thereof.
Handling equipment operatingequipment Test equipment for operating the opening and closing portion of the device.
Reference speed referencevelocity when the door sash linear motion, the actual speed of the door sash movement; when the door sash rotary motion when the door sash and manipulation it means the linear velocity of the outer edge of the connecting end. Meters per second (m/s).
Dwell time resttime
Change between the two operating direction or twice closing pause time between cycles in seconds (s).
Reference point datumpoints Fan windows and doors from the measuring point at each corner 50mm.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB/T 45924-2025Thin triple glazing
- GB 12955-2024Fire-resistant doorsets
- GB 16809-2024Fire resistant windows
- GB/T 40405-2021Technical specification of screen windows and doors for building
- GB/T 29734.3-2020Energy-saving windows and doors for buildings—Part 3: Steel-plastic complex windows and doors
- LY/T 1923-2020Indoor wood-based door
How to Download GB/T 29739-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 29048-2012 — Operating forces - Test method - Windows
GB/T 29555-2013 — Test method of operating forces for doors
GB/T 24293-2026 — Thermostatic faucet
Secure payment via Stripe
Payments accepted
GB/T 29739-2013
$205.00