GB/T 29128-2012General requirements for marine fixed gas fire-extinguishing systems (English PDF)
船舶固定式气体灭火系统通用要求
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for GB/T 29128-2012 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2012
Implementation date
July 1, 2013
Scope
GB/T 29128-2012 is the English-translated version of 船舶固定式气体灭火系统通用要求.
GB/T 29128-2012 is the Chinese standard "General requirements for marine fixed gas fire-extinguishing systems".
Its scope clause reads: This standard specifies the ship fixed gas fire extinguishing system (hereinafter referred to as the "System") of the definition, classification, structure and design, requirements, test side Method, inspection rules.
This standard applies to ship machinery spaces and cargo pump rooms with high-pressure carbon dioxide fixed total flooding fire extinguishing systems, fixed total flooding low pressure Carbon dioxide fire extinguishing system, fixed total flooding heptafluoropropane (HFC-227ea) fire extinguishing systems, fixed total flooding trifluoromethane (HFC-23) Fire System, fixed total flooding mixed gas (IG-541) Fire Extinguishing System.
Use other types of gas extinguishing systems extinguishing agent can also refer to adopt. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 29128-2012
National Standard of the People's Republic of China
- ICS
- 47.020.50
- Classification
- U 23
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 3.1 Mixed gas (IG-541) extinguishing agent inertfireextinguishingagentIG-541
1 Scope
This standard specifies the ship fixed gas fire extinguishing system (hereinafter referred to as the "System") of the definition, classification, structure and design, requirements, test side
Method, inspection rules.
This standard applies to ship machinery spaces and cargo pump rooms with high-pressure carbon dioxide fixed total flooding fire extinguishing systems, fixed total flooding low pressure
Carbon dioxide fire extinguishing system, fixed total flooding heptafluoropropane (HFC-227ea) fire extinguishing systems, fixed total flooding trifluoromethane (HFC-23) Fire
System, fixed total flooding mixed gas (IG-541) Fire Extinguishing System.
Use other types of gas extinguishing systems extinguishing agent can also refer to adopt.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 4396 carbon dioxide fire extinguishing agent
GB/T 4968 fire classification
GB/T 16283 Basic terms fixed fire extinguishing system
GB 18614-heptafluoropropane (HFC-227ea) fire extinguishing agent
GB 20128 Inert gas fire extinguishing agent
GB 50193-1993 carbon dioxide fire extinguishing systems (2010 Edition)
GB 50370-2005 gas fire extinguishing system design specifications
ISO 14520-9 gas extinguishing systems - Physical properties and system design - Part 9. heptafluoropropane (HFC-227ea) fire extinguishing agent (Gaseousfire-extinguishingsystems-Physicalpropertiesandsystem design-Part 9. HFC227ea extinguishment)
ISO 14520-10 for gas extinguishing systems - Physical properties and system design - Part 10. trifluoromethane (HFC-23) extinguishing agent (Gaseousfire-extinguishingsystems-Physicalpropertiesandsystemdesign-Part 10. HFC23extin- guishment)
ISO 14520-15 gas extinguishing systems - Physical properties and system design - Part 15. inert gas (IG-541) extinguishing agent (Gase- ousfire-extinguishingsystems-Physicalpropertiesandsystemdesign-Part 15. IG-541extinguish- ment)
Under fire conditions IEC 60331 test cable (Testsforelectriccableunderfireconditions-Circuitintegrity)
3 Terms and Definitions
GB/T 4968 and GB/T 16283 and as defined in the following terms and definitions apply to this document.
3.1 Mixed gas (IG-541) extinguishing agent inertfireextinguishingagentIG-541
Nitrogen, argon and carbon dioxide, according to a certain weight ratio mixture of extinguishing agent.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Similar standards
How to Download GB/T 29128-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 29128-2012
$315.00