Valid

GB/T 29030-2012Positive displacement CO2 refrigerant compressor(unit) (English PDF)

容积式CO2制冷压缩机(组)

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 29030-2012 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 31, 2012

Implementation date

October 1, 2013

Scope

GB/T 29030-2012 is the English-translated version of 容积式CO2制冷压缩机(组).

GB/T 29030-2012 is the Chinese standard "Positive displacement CO2 refrigerant compressor(unit)".

Its scope clause reads: This standard specifies the displacement CO2 refrigeration compressor (group) in the name of working conditions, performance tolerances and test requirements and test methods, this standard Also it provides input power, cooling coefficient, volumetric efficiency, isentropic efficiency calculation.

Conditions and test methods described in volunteers for measuring Capacity of the compressor, power, volumetric efficiency, the isentropic efficiency and coefficient of performance.

This standard applies to CO2 displacement refrigerant compressors (hereinafter referred to as "compressor") and volumetric CO2 refrigeration compressor (hereinafter Referred to as "unit"). Its clauses include terms and definitions; nominal conditions.

Found what you need?

Document preview — GB/T 29030-2012

National Standard of the People's Republic of China

ICS
27.200
Classification
J 73

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 nominal condition
  • 5 Performance tolerance
  • 7 Test methods
  • 8 input power calculation
  • 9 refrigeration coefficient calculation
  • 10 Calculation of volumetric efficiency
  • 11 isentropic efficiency calculation
  • 13 Symbols and Definitions

1 Scope

This standard specifies the displacement CO2 refrigeration compressor (group) in the name of working conditions, performance tolerances and test requirements and test methods, this standard

Also it provides input power, cooling coefficient, volumetric efficiency, isentropic efficiency calculation. Conditions and test methods described in volunteers for measuring

Capacity of the compressor, power, volumetric efficiency, the isentropic efficiency and coefficient of performance.

This standard applies to CO2 displacement refrigerant compressors (hereinafter referred to as "compressor") and volumetric CO2 refrigeration compressor (hereinafter

Referred to as "unit").

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 2624.1 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 1. General principles and

Claim

GB/T 2624.2 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 2. Orifice

GB/T 2624.3 with the differential pressure measuring device mounted to round pipe full pipe fluid flow Part 3. Nozzles and Venturi

Nozzle

GB/T 2624.4 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 4. Venturi tubes

GB/T 5773-2004 Volume refrigeration compressor performance test methods

JB/T 7249 term refrigeration equipment

3 Terms and Definitions

JB/T 7249 and GB/T 5773 defined by the following terms and definitions apply to this document.

3.1 Volumetric CO2 refrigerant compressors positivedisplacementCO2refrigerantcompressor

By compressing the CO2 refrigerant to achieve cooling and heating function of displacement compressors.

3.2 Volumetric CO2 refrigeration compressor positivedisplacementCO2refrigerantcompressorunit

Assembled together by a CO2 refrigeration compressor displacement, prime mover or other accessories (such as oil pump, oil cooler, oil separator, etc.) for

CO2 refrigerant compressor unit.

3.3 Cooling capacity

Refrigerant gas from the refrigerant mass flow through compressor test measured by multiplying the specific enthalpy of the compressor suction pressure relative to the exhaust port

Corresponding to the saturation temperature of the liquid specific enthalpy (subcritical cycle) or specific enthalpy (transcritical cycle) the difference between the refrigerant before expansion.

4 Nominal Conditions

Compressor (group) in the name of working conditions in accordance with Table 1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 29030-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 29030-2012

$255.00