GB/T 28860-2012Test method for the determination of get time of encapsulating material of powdered epoxy (English PDF)
环氧粉末包封料胶化时间测定方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 28860-2012 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 5, 2012
Implementation date
February 15, 2013
Scope
GB/T 28860-2012 is the English-translated version of 环氧粉末包封料胶化时间测定方法.
GB/T 28860-2012 is the Chinese standard "Test method for the determination of get time of encapsulating material of powdered epoxy". Its scope clause reads: This standard specifies the electronic components with epoxy powder coating material gelling time measuring method.
This standard applies to epoxy powder encapsulation materials gel time determination does not apply to short gel time (less than 15s) epoxy powder coating Gelling material measurement time.
Its clauses include principle of the method; devices and materials; sample; measuring step.
Found what you need?
Document preview — GB/T 28860-2012
National Standard of the People's Republic of China
- ICS
- 31.020
- Classification
- L 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 principle of the method
- 3 devices and materials
- 4 Sample
- 5 measuring step
1 Scope
This standard specifies the electronic components with epoxy powder coating material gelling time measuring method.
This standard applies to epoxy powder encapsulation materials gel time determination does not apply to short gel time (less than 15s) epoxy powder coating
Gelling material measurement time.
2 principle of the method
A certain amount of epoxy powder coating material sample is placed is heated to a predetermined temperature gel time tester curing pan, measured by the sample
Melted to become no longer drawing time elapsed.
3 devices and materials
3.1
Thermometer, range 0 °C ~ 300 °C, accurate to 1 °C.
3.2
range suitable timer, minimum scale 1s.
3.3
paddles, Phi5mm glass rod.
3.4
heating plate, the diameter of 140mm or 140mm × 140mm, thickness 15mm ~ 20mm, can control temperature at 150 °C ±
1 °C. Heating plate has a circular polishing pits (cured disc) for placement test sample preparation curing disc diameter Phi (16 ± 0.1) mm, depth
4mm. Heating plate is placed on one side of the thermometer bore below the upper surface of the cured plate and extending horizontally near the center of the disc curing hole
Cured from the top center of the disc is not more than 2mm.
3.5
verification was used to verify the heating plate temperature, the material (melting point salt standard substance) known melting point.
3.6
measuring spoons capacity of 1mL, for a sample into a curing tray.
3.7
release agent such as polytetrafluoroethylene dispersion aerosol or equivalent substances.
3.8
scraper for the eradication of the sample plate heat cured on the disc, made of a material hardness is less than the heating plate.
4 Sample
Two samples, each 1mL.
5 measuring step
5.1
Cleaning cure plate and heating plate.
5.2
The heating plate was placed in a laboratory is not ventilated location, turn on the power switch, the heating plate was adjusted to 150 °C ± 1 °C or product standard gauge
Given temperature, stable for at least 10min. Use a small piece of known melting point of verification was placed on a hot plate, to verify whether the surface temperature of the heating block
Desired temperature.
Glass rod in a circular motion agitating the molten sample. When the test sample starts to thicken, stirring while maintaining every 2s ~ 3s, will
Lift the glass rod (height approximately 10mm) from the molten sample. If drawing a glass rod that brought the formation of brittle fracture can no longer be brushed […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 28860-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 28860-2012
$75.00