Scope

GB/T 28722-2012 is the English-translated version of 氨基酸中铁和铅的测定 原子吸收光谱法.

GB/T 28722-2012 is the Chinese standard "Determination of iron and lead in amino acids - Atomic absorption spectrometry". Its scope clause reads: This standard specifies the method for the determination of amino acids in iron and lead by atomic absorption spectrometry.

This standard applies to the determination of amino acids in the iron and lead by graphite furnace atomic absorption spectrometry of lead measured detection limit of 0.005mg/kg;.

Fire Flame atomic absorption spectrometry of lead measured detection limit of 0.1mg/kg, iron measured detection limit of 2mg/kg. Its clauses include lead graphite furnace atomic absorption spectrometry.

Found what you need?

Document preview — GB/T 28722-2012

National Standard of the People's Republic of China

ICS
71.040.50
Classification
G 85

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Lead graphite furnace atomic absorption spectrometry
  • 3.1 Principle
  • 3.2 Reagents
  • 3.2.1 Unless otherwise specified, all reagents superior grade pure water GB/T 6682 provisions of the water level.
  • 3.2.2 nitrate.
  • 3.2.3 perchloric acid.
  • 3.2.4 nitric acid solution (0.5mol/L)
  • 3.2.5 nitric acid solution (1mol/L)
  • 3.2.6 solution of ammonium dihydrogen phosphate (20g/L)
  • 3.2.7 mixed acid [nitric perchloric acid (41)]
  • 3.2.8 Lead standard solution (1mg/mL)

1 Scope

This standard specifies the method for the determination of amino acids in iron and lead by atomic absorption spectrometry.

This standard applies to the determination of amino acids in the iron and lead by graphite furnace atomic absorption spectrometry of lead measured detection limit of 0.005mg/kg;. Fire

Flame atomic absorption spectrometry of lead measured detection limit of 0.1mg/kg, iron measured detection limit of 2mg/kg.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article

Member. For undated references, the latest edition (including any amendments) applies to this document.

Laboratory use specifications and test methods GB/T 6682 Analysis

3 Lead graphite furnace atomic absorption spectrometry

3.1 Principle

The sample was ashing or acid digestion after injection graphite furnace atomic absorption spectrophotometer, the light atoms of lead emitted by the light source, the absorption

Its 283.3nm resonance line, in a certain concentration range, the absorption value is proportional to the amount of lead, compared with standard series quantitation.

3.2 Reagents

3.2.1

Unless otherwise specified, all reagents superior grade pure water GB/T 6682 provisions of the water level.

3.2.2

nitrate.

3.2.3

perchloric acid.

3.2.4 nitric acid solution (0.5mol/L)

Take 3.2mL nitric acid (3.2.2) was added 50mL of water and diluted to 100mL.

3.2.5 nitric acid solution (1mol/L)

Take 6.4mL nitric acid was added 50mL of water and diluted to 100mL.

3.2.6 solution of ammonium dihydrogen phosphate (20g/L)

Weigh 2.0g of ammonium dihydrogen phosphate was dissolved in water and diluted to 100mL.

3.2.7 mixed acid [nitric perchloric acid (41)]

Take four parts of nitric acid was mixed with 1 part of perchlorate.

3.2.8 Lead standard solution (1mg/mL)

Accurately weigh 1.598g lead nitrate, plus 10mL0.5mol/L nitric acid solution dissolved quantitatively transferred into a 1000mL volumetric flask and set

Capacity. This is equivalent to 1mg solution 1mL lead. Store in a polyethylene bottle, 4 °C preservation.

3.2.9 Lead standard solution

Accurate Pipette 1.00mL lead standard stock solution in 1000mL volumetric flask to volume with water, shake well and reserve. Pipette diluted respectively

Solution 0mL, 1.00mL, 2.00mL, 4.00mL, 6.00mL, 8.00mL in 100mL flask, add nitric acid (0.5mol/L) […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 28722-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 28722-2012

$135.00