GB/T 28705-2012Non-destructive testing - Test method for pulsed eddy current testing (English PDF)
无损检测 脉冲涡流检测方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 28705-2012 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 3, 2012
Implementation date
March 1, 2013
Scope
GB/T 28705-2012 is the English-translated version of 无损检测 脉冲涡流检测方法.
GB/T 28705-2012 is the Chinese standard "Non-destructive testing - Test method for pulsed eddy current testing". Its scope clause reads: This standard sets out without removing the covering layer of the wall thickness due to corrosion thinning large area for detecting pulsed eddy current inspection Measuring method.
This standard applies to detect the thickness of carbon steel, low alloy steel and other ferromagnetic material is 3mm ~ 65mm, the thickness of the cover layer 0 ~ 200mm, a temperature of -150 °C ~ 500 °C in the member, and no less than the diameter of the pipe or tube of 50mm.
This standard does not apply to pitting, pits and other local wall thickness caused by thinning and crack detection type defects. This standard does not establish the evaluation criterion, specific criteria by the detection and users of mutual consultation.
This standard does not fully given when the safety requirements for testing, the use of this standard to establish appropriate safety obligation of the parties prior to detection And protection guidelines. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 28705-2012
National Standard of the People's Republic of China
- ICS
- 19.100
- Classification
- J 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 3.1 Overlay coating
- 3.2 Bending point
- 3.3 The characteristic time
1 Scope
This standard sets out without removing the covering layer of the wall thickness due to corrosion thinning large area for detecting pulsed eddy current inspection
Measuring method.
This standard applies to detect the thickness of carbon steel, low alloy steel and other ferromagnetic material is 3mm ~ 65mm, the thickness of the cover layer
0 ~ 200mm, a temperature of -150 °C ~ 500 °C in the member, and no less than the diameter of the pipe or tube of 50mm.
This standard does not apply to pitting, pits and other local wall thickness caused by thinning and crack detection type defects.
This standard does not establish the evaluation criterion, specific criteria by the detection and users of mutual consultation.
This standard does not fully given when the safety requirements for testing, the use of this standard to establish appropriate safety obligation of the parties prior to detection
And protection guidelines.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 9445 NDT personnel qualification and certification
GB/T 11344 NDT contact ultrasonic pulse echo thickness measurement method
GB/T 12604.6 Terminology for nondestructive testing Eddy current testing
JB/T 4730.3 Non-destructive testing of pressure equipments - Part 3. Ultrasonic testing
3 Terms and Definitions
GB/T 12604.6 defined and the following terms and definitions apply to this document.
3.1 Overlay coating
In bonding, adsorption, wrapped, twisted, or other forms of mosaic covering the surface of the subject matter, such as paints, plastics, asphalt, rock wool, foam,
Filament wire mesh, cement, carbon (glass) fiber, and other marine life. Cover layer generally consists of coating, insulation and protective layers and other industrial equipment used composition.
3.2 Bending point
In double logarithmic coordinates, pulsed eddy current detection signal waveform transition from straight segments to curve segments turning point.
3.3 The characteristic time
And the time corresponding to the bending point, characterize eddy diffusion from the surface of the subject member to the bottom of the time, and its size is proportional to the magnetic permeability detection element,
Conductivity and thickness of the square.
4. Summary
The basic principle of pulsed eddy current testing method is shown in Figure 1. Through with a single rectangular pulse or square wave current excitation coil emits a magnetic […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 28705-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 28705-2012