GB/T 28606-2012 is the English-translated version of 涂料中全氟辛酸及其盐的测定 高效液相色谱-串联质谱法.

GB/T 28606-2012 is the Chinese standard "Determination of perfluorooctanoic acid and salt in the coating -High performance liquid chromatography-tandem mass spectrometry".

Its scope clause reads: This standard specifies the paint perfluorooctanoic acid (PFOA) and its salts by high performance liquid chromatography - tandem mass spectrometry.

This standard applies to octylate (PFOA) and its salts measured perfluorinated coating. The detection limit of this standard to perfluorooctanoic acid (PFOA) in terms of the mass fraction of 0.0002%. Its clauses include reagents and materials; instruments.

Found what you need?

Document preview — GB/T 28606-2012

National Standard of the People's Republic of China

ICS
71.040.50
Classification
G 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 4 Reagents and materials
  • 5 Instruments

1 Scope

This standard specifies the paint perfluorooctanoic acid (PFOA) and its salts by high performance liquid chromatography - tandem mass spectrometry.

This standard applies to octylate (PFOA) and its salts measured perfluorinated coating.

The detection limit of this standard to perfluorooctanoic acid (PFOA) in terms of the mass fraction of 0.0002%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

Laboratory use specifications and test methods GB/T 6682 Analysis

Principle 3

Ultrasonic extraction with water paint perfluorooctanoic acid (PFOA) and its salts, centrifuged, the supernatant take part after solid phase extraction column purification

After the eluent volume injected into the HPLC - tandem mass spectrometry analysis, external standard.

4 Reagents and materials

Unless otherwise indicated, all reagents were of analytical grade water as a water GB/T 6682 regulations.

4.1 acetonitrile

HPLC grade.

4.2 ammonium acetate (10mmol/L)

Weigh the appropriate amount of ammonium acetate to a beaker, dissolved in water and transferred to a 1L volumetric flask.

4.3 perfluorooctanoic acid (PFOA) standard substance

mass fraction purity of not less than 96%.

4.4 SPE

Oasis(R) HLB or equivalent person; prior to use successively with 3mL methanol, 3mL water activation.

Note. [Oasis(R) HLB] is provided by the American Waters company, give this information is for the convenience of users of this standard does not mean that the production

Approved products, if other equivalent products having the same effect, you can use these equivalent products.

4.5 microporous membrane

0.2µm, organic phase.

4.6 standard stock solution

Weigh accurately perfluorooctanoic acid (PFOA) Standards 0.1g, accurate to 0.1mg, the transfer to dissolved with acetonitrile

100mL flask, acetonitrile volume, shaking uniform, that was perfluorooctanoic acid (PFOA) standard stock solution at a concentration of 1000µg/mL of.

4.7 standard solution

accurate Pipette stock standard solution 1.00mL, to 100mL volumetric flask, acetonitrile volume, shaking uniform, that was perfluorooctanoate

Acid (PFOA) at a concentration of 10µg/mL of the standard solution.

5 Instruments

5.1

high performance liquid chromatography - tandem mass spectrometry with electrospray ionization (ESI).

5.2 Analysis of balance

a sense of the amount of 0.01g, 0.1g.

5.3

ultrasonic cleaning.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 28606-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 28606-2012

$125.00