GB/T 27813-2011Analytical methods of anhydrous potassium fluoride (English PDF)
无水氟化钾分析方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 27813-2011 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 30, 2011
Implementation date
June 1, 2012
Scope
GB/T 27813-2011 is the English-translated version of 无水氟化钾分析方法.
GB/T 27813-2011 is the Chinese standard "Analytical methods of anhydrous potassium fluoride". Its scope clause reads: This Standard specifies the analytical methods for potassium fluoride content and various impurities in anhydrous potassium fluoride.
This Standard applies to anhydrous potassium fluoride products.
Its clauses include safety tips; general; determination of potassium fluoride content; determination of chloride content; determination of loss on ignition; determination of free acid or free base content; determination of sulfate content; determination of fluorosilicate content; determination of water-insoluble matter content.
Found what you need?
Document preview — GB/T 27813-2011
National Standard of the People's Republic of China
- ICS
- 71.060.01
- Classification
- G 10
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Safety tips4
- 4 General5
- 5 Determination of potassium fluoride content5
- 6 Determination of chloride content6
- 7 Determination of loss on ignition8
- 8 Determination of free acid or free base content9
- 9 Determination of sulfate content10
- 10 Determination of fluorosilicate content12
- 11 Determination of water-insoluble matter content14
- content15
- Annex A (normative) Pretreatment and regeneration of H-732 ion exchange resin18
1 Scope
This Standard specifies the analytical methods for potassium fluoride content and various impurities in anhydrous potassium fluoride.
This Standard applies to anhydrous potassium fluoride products.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682-2008, Water for analytical laboratory use -- Specification and test methods
HG/T 3696.1, Inorganic chemicals for industrial use -- Preparations of standard and reagent solutions for chemical analysis -- Part 1: Preparations of standard volumetric solutions
HG/T 3696.2, Inorganic chemicals for industrial use. Preparations of standard and reagent solutions for chemical analysis. Part 2: Preparations of standard solutions for impurity
HG/T 3696.3, Inorganic chemicals for industrial use. Preparations of standard and reagent solutions for chemical analysis. Part 3: Preparations of reagent solutions
3 Safety tips
Some of the reagents used in this analytical method are toxic or corrosive. Exercise caution when handling. If splashed on skin, rinse immediately with water. In severe cases, seek medical attention immediately. Potassium fluoride is inherently toxic and highly corrosive. Exercise caution when handling and wear protective equipment.
4 General
Unless otherwise specified, the reagents and water used in this Standard refer to analytically pure reagents and Grade three water as specified in GB/T 6682-2008. The standard titration solutions, impurity standard solutions, preparations, and products used in the tests, unless otherwise specified, are prepared in accordance with HG/T 3696.1, HG/T 3696.2, and HG/T 3696.3.
5 Determination of potassium fluoride content
5.1 Method summary
Dissolve the test material in water. Exchange the solution with a strong acid cation exchange resin to generate hydrofluoric acid. Titrate with a standard sodium hydroxide solution using phenolphthalein as an indicator to obtain the result.
5.2 Reagents and materials
5.2.1 Sodium hydroxide standard titration solution
c(NaOH) ~ 0.5 mol/L.
5.2.2 Phenolphthalein indicator solution
10 g/L.
5.2.3
Asbestos.
5.2.4
H-732 ion exchange resin.
5.2.5
Carbon dioxide-free water.
5.3 Instruments and equipment
5.3.1 Ion exchange column
polyethylene plastic tube; inner diameter is 25 mm; length is 500 mm; capable of controlling flow rate.
5.3.2
Plastic beaker.
5.4 Analysis procedure
5.4.1 Preparation of ion exchange column
Secure the ion exchange column to the stand. Close the stopcock. Fill the bottom of the column with 1 cm thick asbestos. Pour approximately 10 mL of water into the column to moisten it. Pour pretreated H-732 ion exchange resin into the column to a resin bed height of 400 mm. Before use, treat the column according to the instructions in Annex
A.
5.4.2 Determination
Weigh approximately 1 g of specimen to the nearest 0.0002 g. Place in a 100 mL plastic beaker. Dissolve in 50 mL of CO2 -free water and inject into the ion exchange column.
Use CO2 -free water as the eluent. Control the column flow rate to 5.0 mL/min~6.0 mL/min. Wash until the effluent is neutral (check with pH paper). Collect the effluent in a 500 mL plastic beaker. Add 2 drops of phenolphthalein indicator solution. Titrate with sodium hydroxide standard titrant until the solution turns pink and remains so for
30 s.
5.5 Result calculation
The potassium fluoride content is calculated as the mass fraction w1 of potassium fluoride (KF) according to formula (1):
Where,
V - The volume of the sodium hydroxide standard titrant consumed during the titration, in milliliters (mL);
c - The exact concentration of the sodium hydroxide standard titrant, in moles per liter (mol/L);
m - The mass of the test material, in grams (g);
w2 - The mass fraction of chloride measured in Chapter 6;
w4 - The mass fraction of free acid measured in Chapter 8;
w6 - The mass fraction of sulfate measured in Chapter 9;
M - The molar mass of potassium fluoride (KF), in grams per mole (g/mol) (M = 58.10).
The arithmetic mean of the parallel determination results is taken as the determination result. The absolute difference between the two parallel determination results shall not exceed 0.2%.
6 Determination of chloride content
6.1 Method summary
7 Determination of loss on ignition
7.1 Apparatus and equipment
7.1.1
Platinum crucible.
7.1.2 High-temperature furnace
the temperature can be controlled within 650°C ± 20°C.
7.2 Analysis steps
Weigh approximately 5 g of specimen to the nearest 0.0002 g in a platinum crucible that has been calcined at 650°C ± 20°C to a constant mass. Place the crucible in a high- temperature furnace at 650°C ± 20°C for 2 h, remove it, and weigh it after cooling.
7.3 Result calculation
The loss on ignition is calculated as mass fraction w3 according to formula (3):
Where, m 1 - The mass of the test material and crucible before ignition, in grams (g);
m 2 - The mass of the test material and crucible after ignition, in grams (g);
m - The mass of the test material, in grams (g).
The arithmetic mean of the parallel determination results is taken as the determination result. The absolute difference between the two parallel determination results shall not exceed 0.05%.
8 Determination of free acid or free base content
8.1 Reagents and materials
8.1.1 Sodium hydroxide standard titration solution
c(NaOH) ~ 0.05 mol/L.
8.1.2 Hydrochloric acid standard titration solution
c(HCl) ~ 0.05 mol/L.
8.1.3 Phenolphthalein indicator solution
10 g/L.
8.1.4
Carbon dioxide-free water.
8.2 Apparatus
8.2.1
Plastic beaker.
8.2.2 Microburette
the graduation is 0.02 mL or 0.05 mL.
8.3 Analysis steps
Weigh approximately 5 g of specimen to the nearest 0.0002 g. Place in a 250 mL plastic beaker. Dissolve in 50 mL of carbon dioxide-free water. Add 2 drops of phenolphthalein indicator solution.
If the test solution is colorless, titrate with sodium hydroxide standard solution until the solution turns pink and remains pink for 30 s.
If the test solution is red, titrate with standard hydrochloric acid solution until the solution becomes colorless.
8.4 Result calculation
The free acid content is calculated as the mass fraction w4 of hydrofluoric acid (HF) according to formula (4):
Where,
V - The volume of the sodium hydroxide standard titrant consumed during the titration, in milliliters (mL);
c - The exact concentration of the sodium hydroxide standard titrant, in moles per liter (mol/L);
m - The mass of the test material, in grams (g);
M - The molar mass of hydrofluoric acid (HF), in grams per mole (g/mol) (M = 20.01).
The free alkali content is calculated as the mass fraction w5 of potassium hydroxide (KOH) according to formula (5):
Where,
V - The volume of the standard hydrochloric acid solution consumed during the titration, in milliliters (mL);
c - The exact concentration of the standard hydrochloric acid solution, in moles per liter (mol/L);
m - The mass of the test material, in grams (g);
M - The molar mass of potassium hydroxide (KOH), in grams per mole (g/mol) (M =
56.11).
The arithmetic mean of the parallel determination results is taken as the determination result. The absolute difference between the two parallel determination results shall not exceed 0.02%.
9 Determination of sulfate content
9.1 Method summary
The specimen is placed in a hydrochloric acid medium. Boric acid is added to complex the fluoride ions. Then, an excess of barium chloride solution is added to precipitate the sulfate ions into barium sulfate. Calculate the sulfate content based on the weight of the barium sulfate.
9.2 Reagents
9.2.1
Boric acid.
9.2.2 Hydrochloric acid solution
1 + 3.
9.2.3 Barium chloride solution
100 g/L.
9.2.4 Methyl orange indicator solution
1 g/L.
9.3 Instruments and equipment
10 Determination of fluorosilicate content
10.1 Method summary
Fluoride ions in the specimen react with boric acid to form . Silicic acid reacts quantitatively with ammonium molybdate in a slightly acidic solution to form silicomolybdate heteropolyacid (silicomolybdate yellow). Adding a reducing agent reduces silicomolybdate yellow to silicomolybdate blue. Measure the color at 795 nm using a spectrophotometer or UV-visible spectrophotometer.
10.2 Reagents
10.2.1 Boric acid solution
40 g/L.
10.2.2 Sulfuric acid solution
1 + 33.
10.2.3 Ammonium molybdate solution
100 g/L (refresh if precipitation occurs).
10.2.4 Oxalic acid solution
50 g/L.
10.2.5 Stannous chloride hydrochloric acid solution
20 g/L.
10.2.6 Silica standard solution
1 mL of solution contains 0.01 mg of silicon dioxide (SiO2 ).
Pipette 1.00 mL of the silica standard solution prepared according to HG/T 3696.2 into a 100 mL volumetric flask. Dilute to the mark with water and shake well. Prepare this solution immediately before use.
10.2.7
Saturated 2,4-dinitrophenol indicator solution.
10.3 Instrument
10.3.1 Spectrophotometer or UV-visible spectrophotometer
equipped with a 2 cm cuvette.
10.3.2
Plastic beaker.
10.4 Analysis steps
11 Determination of water-insoluble matter content
11.1 Method summary
Dissolve the specimen. Filter out the water-insoluble matter. Burn in a high-temperature furnace until the mass remains constant. Calculate the water-insoluble matter content.
11.2 Reagents
Barium chloride solution: 100 g/L.
11.3 Instruments and equipment
11.3.1
Plastic beaker (polytetrafluoroethylene).
11.3.2
Plastic funnel.
11.3.3 High-temperature furnace
the temperature can be controlled within 500°C ±
20°C.
11.4 Analysis steps
Weigh approximately 30 g of specimen to the nearest 0.01 g. Place in a 250mL plastic beaker. Add 100 mL of water and shake well. Heat the plastic beaker on a hot plate at low temperature to completely dissolve the specimen. Filter through a plastic funnel using slow-flow quantitative filter paper. Wash with water until fluoride ions are free (test with barium chloride solution). Place the filter paper in a porcelain crucible that has been calcined at 500°C ±20°C to a constant mass. Ash the crucible. Then calcine the crucible in a high-temperature furnace at 500°C±20°C until the mass is constant.
Remove the crucible. Cool and weigh.
11.5 Result calculation
The water-insoluble content is expressed as mass fraction w8 and is calculated according to formula (8):
Where, m 1 - The mass of the porcelain crucible and water-insoluble substance, in grams (g);
m 2 - The mass of the porcelain crucible, in grams (g);
m - The mass of the test material, in grams (g).
The arithmetic mean of the parallel determination results is taken as the determination result. The absolute difference between the two parallel determination results shall not exceed 0.05%.
12 Determination of arsenic, iron, lead, chromium, silicon, boron, calcium and nickel content
12.1 Method summary
Inductively coupled plasma atomic emission spectrometry (ICP-AES) is used for simultaneous determination of multiple elements.
12.2 Reagents
12.2.1 Nitric acid solution
2+98 (guaranteed reagent).
12.2.2 Nitric acid solution
1+10 (guaranteed reagent).
12.2.3 Mixed standard solution A
1 mL of solution contains 0.02 mg each of arsenic (As), iron (Fe), lead (Pb), chromium (Cr), boron (B), calcium (Ca), and nickel (Ni).
Pipette 2.00 mL of arsenic, iron, lead, chromium, boron, calcium, and nickel standard solutions prepared according to HG/T 3696.2 into a 100 mL volumetric flask. Dilute to the mark with nitric acid solution (12.2.1). Shake well. It shall be valid for 6~12 months.
12.2.4 Standard solution B
1 mL of solution contains 0.05 mg of silicon (Si).
Pipette 5.00 mL of the silicon standard solution prepared according to HG/T 3696.2 into a 100 mL volumetric flask. Dilute to the mark with nitric acid solution (12.2.1).
Shake well. It shall be valid for 6~12 months.
12.2.5 Grade 1 water
comply with the requirements of GB/T 6682-2008.
12.3 Instruments and equipment
12.3.1 Inductively coupled plasma-atomic emission spectrometer (ICP-AES)
12.3.2 Fluorine-resistant torch
12.3.3 High-salt nebulizer
12.3.4 Plastic beaker (PTFE)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 27813-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 27813-2011
$225.00