GB/T 27577-2011Determination of vitamin B5(pantothenic acid) and provitamin B5 (D-fantothenol) in cosmetics by HPLC/UV and HPLC MS/MS (English PDF)
化妆品中维生素B5(泛酸)及维生素原B5(D-泛醇)的测定 高效液相色谱紫外检测法和高效液相色谱串联质谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 27577-2011 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 5, 2011
Implementation date
March 1, 2012
Scope
GB/T 27577-2011 is the English-translated version of 化妆品中维生素B5(泛酸)及维生素原B5(D-泛醇)的测定 高效液相色谱紫外检测法和高效液相色谱串联质谱法.
GB/T 27577-2011 sets out two methods for determining vitamin B5 (pantothenic acid) and provitamin B5 (D-panthenol) in cosmetics: high performance liquid chromatography with ultraviolet detection, and high performance liquid chromatography tandem mass spectrometry.
Clause 1 states that it applies to the quantitative determination of those two substances in cosmetics, and gives, for the method using HPLC with UV detection, a detection limit of 30 µg/g and a limit of quantification of 100 µg/g for pantothenic acid and D-panthenol, and for the tandem mass spectrometry method a detection limit of 30 ng/g and a limit of quantification of 100 ng/g.
The clauses shown in the draft are Scope, Normative references, Principle and Reagents and materials.
Clause 3 describes the principle: in a two-phase system formed by water and a water-immiscible organic solvent such as chloroform or iso-octane, vitamin B5, that is pantothenic acid and its salts such as sodium pantothenate and calcium pantothenate, and provitamin B5 (D-panthenol) distribute into the aqueous phase, while oil-soluble cosmetic ingredients dissolve in the organic phase and the surfactants in the cosmetic concentrate at the oil-water interface, which gives a first separation of the analytes from those components.
It adds that macromolecules are then removed from the extract with a potassium ferrocyanide and zinc acetate co-precipitating agent, that pantothenic acid and D-panthenol are enriched under acidic conditions on a C18 solid phase extraction stationary phase so that other water-soluble interferences can be washed away, and that after elution they are measured by reversed-phase high performance liquid chromatography with a UV detector or a tandem quadrupole mass spectrometer and quantified from a standard curve by the external standard method.
Clause 4 lists the reagents and materials, with the English name, CAS number, molecular formula, molecular structure, molecular weight and purity of the standard substances given in Table 1, and with methanol and formic acid each listed in a chromatographically pure and an AR grade.
Clause 2 cites GB/T 6379.1, GB/T 6379.2 and GB/T 6682. It was issued on 2011-12-05 and has applied since 2012-03-01.
Found what you need?
Document preview — GB/T 27577-2011
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 Reagents and materials
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
1 Scope
This standard specifies the cosmetics Vitamin B5 (pantothenic acid) and provitamin B5 (D- panthenol) determined by HPLC with UV detection And high performance liquid chromatography tandem mass spectrometry two ways.
This standard applies to cosmetics quantitative vitamin B5 (pantothenic acid) and provitamin B5 (D- panthenol) Determination of HPLC UV detection
Measurement method of pantothenic acid, D- panthenol detection limit of 30µg/g, the limit of quantification of 100µg/g. High performance liquid chromatography tandem mass spectrometry of pantothenic acid, D- pan Alcohol detection limit of 30ng/g; limit of quantification was 100ng/g.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6379.1 measurement methods and results of Accuracy (trueness and precision) - Part 1: General principles and definitions
GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2: Determine the standard measurement method to repeat Of the basic methods of reproduction
GB/T 6682 Laboratory use specifications and test methods Analysis
3 Principle
In the two-phase system of water and a water-immiscible organic solvent (such as chloroform or iso-octane, etc.) formed, vitamin B5 (pantothenic acid and Its salts (such as sodium and calcium pantothenate Pan)) and provitamin B5 (D- panthenol) are distributed in the aqueous phase, oil-soluble cosmetic ingredients soluble in organic Phase, and cosmetics are enriched in surfactants at the oil-water interface. You can use two-phase system and vitamin B5 provitamin B5 and Cosmetics and oil-soluble surfactant composition is initially separated potassium ferrocyanide - co-precipitating agent to remove the zinc acetate extract macromolecules group quality. After pantothenic acid under acidic conditions and D- panthenol enriched in the solid phase extraction C18 stationary phase, the removal of other water-soluble interferences, with 40% A Alcohol aqueous solution elution reversed-phase high-performance liquid chromatography, UV detector or a tandem quadrupole mass spectrometry, a standard curve of external standard.
4 Reagents and materials
Unless otherwise indicated, the water is a water GB/T 6682 specified.
4.1 Standard substance English name, CAS number, molecular formula, molecular structure, molecular weight and purity are shown in Table 1.
4.2 Methanol. chromatographically pure.
4.3 Methanol. AR.
4.4 Formic acid. AR.
4.5 Formic acid. Chromatographic pure.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6379.1Accuracy (trueness and precision) of measurement methods and results -- Part 1: General principles and definitions
- GB/T 6379.2Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
- GB/T 6682Water for analytical laboratory use - Specification and test methods
Similar standards
How to Download GB/T 27577-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6379.1-2004 — Accuracy (trueness and precision) of measurement methods and results -- Part 1: General principles and definitions
GB/T 6379.2-2004 — Measurement methods and results -- Accuracy (trueness and precision) -- Part 2: Determine the standard methods of measurement repeatability and reproducibility of the basic method
GB/T 6379.2-2026 — Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
GB/T 27577-2011
$225.00