Valid

GB/T 26802.2-2017Industrial control computer system—General specification—Part 2:Safety requirements for industrial control computer (English PDF)

工业控制计算机系统 通用规范 第2部分:工业控制计算机的安全要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (48 pages)

Need quotation for your management?

Get a formal quotation for GB/T 26802.2-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/T 26802.2-2017 is the English-translated version of 工业控制计算机系统 通用规范 第2部分:工业控制计算机的安全要求.

GB/T 26802.2-2017 is the Chinese standard "Industrial control computer system—General specification—Part 2:Safety requirements for industrial control computer".

Its scope clause reads: GB/T 26802 provisions of this part of a variety of industrial production equipment, measuring, monitoring and control of computer anti-shock and electrocautery Injury, anti-mechanical danger, flame spread from inside the computer to prevent the impact of high temperature safety requirements.

This section also provides through the inspection and Type test to identify whether the device meets the requirements of this section. This section applies to a variety of industrial equipment, measurement, monitoring and control computer products.

This section does not include non-safety equipment functions, performance or other characteristics, the effectiveness of transport packaging, electromagnetic compatibility (EMC) Seeking, functional safety, protective measures against the explosive environment, maintenance (repair), maintenance (repair) personnel protection. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 26802.2-2017

National Standard of the People's Republic of China

ICS
25.040.40
Classification
N 18

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword V.
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 test
  • 4.1 Overview
  • 4.2 Test sequence
  • 4.3 benchmark test conditions
  • 4.3.1 Environmental conditions
  • 4.3.2 equipment status
  • 4.4 Single fault conditions test
  • 4.4.1 Overview
  • 4.4.2 Application of fault conditions
  • 4.4.3 Test duration
  • 4.4.4 Conformity after application of fault conditions
  • 5 signs and documents
  • 5.1 mark
  • 5.1.1 Overview
  • 5.1.2 logo
  • 5.1.3 Power
  • 5.1.4 Fuse
  • 5.1.5 terminals, connectors and operating device
  • 5.1.6 Switches and Circuit Breakers
  • 5.1.7 Controls and Indicators
  • 5.1.8 Industrial control computer with double or reinforced insulation
  • 5.2 Warning signs
  • 5.3 logo durability
  • 5.4 Documents
  • 5.4.1 Overview
  • 5.4.2 Industrial control computer rating
  • 5.4.3 Industrial Control Computer Installation
  • 5.4.4 Industrial Control Computer Operation
  • 5.4.5 Industrial Control Computer Maintenance
  • 6 anti-shock
  • 6.1 Overview
  • 6.2 Determination of accessible components
  • 6.2.1 Overview
  • 6.2.2 Inspection
  • 6.2.3 Hazardous electrical components above the opening
  • 6.2.4 pre-conditioning control of the opening
  • 6.3 Permissible limits of accessible components
  • 6.3.1 Overview
  • 6.3.2 Limit under normal conditions
  • 6.3.3 Limitations under single fault conditions
  • 6.4 Protection under normal conditions
  • 6.5 Single fault protection
  • 6.5.1 Overview
  • 6.5.2 Protection Connection
  • 6.5.3 Double insulation and reinforced insulation
  • 6.5.4 Protection Impedance
  • 6.5.5 Industrial Control Computer Automatic Disconnection
  • 6.6 Connection with External Circuit
  • 6.7 Clearances and creepage distances
  • 6.7.1 Overview
  • 6.7.2 General requirements
  • 6.7.3 Grid Power Supply Circuit
  • 6.7.4 Circuits other than the mains power supply circuit
  • 6.8 Dielectric Strength Test Procedure
  • 6.8.1 Reference test site
  • 6.8.2 Wet Pretreatment
  • 6.8.3 Test Implementation
  • 6.8.4 Voltage test
  • 6.9 Structural requirements for protection against electric shock
  • 6.9.1 Overview
  • 6.9.2 double insulated or reinforced insulation housing
  • 6.10 and the power supply connection
  • 6.10.1 Power Cord
  • 6.10.2 Installation of Non-detachable Power Cables
  • 6.10.3 Plugs and Connectors
  • 6.11 Input Power Disconnect
  • 6.11.1 Overview
  • 6.11.2 Exceptions
  • 6.11.3 according to the type of power requirements
  • 6.11.4 Disconnect device
  • 7 anti-mechanical danger
  • 8 resistant to mechanical shock and impact
  • 8.1 Overview
  • 8.2 Housing rigidity test
  • 8.2.1 Static test
  • 8.2.2 Dynamic test
  • 9 to prevent the spread of fire
  • 9.1 Overview
  • 9.2 Elimination or reduction of ignition sources within the equipment
  • 9.3 In the event of a fire, control the flame in the equipment
  • 9.3.1 Overview
  • 9.3.2 Structural Requirements
  • 9.4 limit circuit
  • 9.5 Over-current protection
  • 10 equipment temperature limits and heat

1 Scope

GB/T 26802 provisions of this part of a variety of industrial production equipment, measuring, monitoring and control of computer anti-shock and electrocautery

Injury, anti-mechanical danger, flame spread from inside the computer to prevent the impact of high temperature safety requirements. This section also provides through the inspection and

Type test to identify whether the device meets the requirements of this section.

This section applies to a variety of industrial equipment, measurement, monitoring and control computer products.

This section does not include non-safety equipment functions, performance or other characteristics, the effectiveness of transport packaging, electromagnetic compatibility (EMC)

Seeking, functional safety, protective measures against the explosive environment, maintenance (repair), maintenance (repair) personnel protection.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

Thermoplastics - Determination of Vicat softening temperature (VST) GB/T 1633-2000

GB/T 4208-2008 enclosure protection (IP code)

GB 4793.1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1. General requirements

GB/T 5013 (all parts) Rated voltage 450V/750V and below rubber insulated cables

GB/T 5023 (all parts) rated voltage 450V/750V and below PVC insulated cables

GB/T 11020-2005 solid non-metallic materials exposed to the flame source flammability test list

Electrical insulation - Heat resistance and representation

Industrial plugs and socket connectors and couplers Part 1 GB/T 11918.1 General requirements

GB/T 11918.2 Industrial plugs and sockets - Part 2. Dimensional compatibility of electrical accessories with pins and inserts

Interchangeability requirements

GB/T 14048.1 low-voltage switchgear and control equipment General

GB/T 14048.3 low-voltage switchgear and control equipment Part 3. Low-voltage switches, isolators, disconnectors and fuse combinations

Electrical appliances

GB/T 15934 electrical accessories wire components and interconnecting wire components

GB/T 16927 (all parts) high voltage test technology

IEC 60027 electrician text symbols (Lettersymbolstobeusedinelectricaltechnology)

IEC 60664-3.2010 Insulation coordination of low-voltage systems Part 3. Use of coatings to improve the insulation of printed circuit board systems (Insulationcoordinationforequipmentwithinlow-voltagesystems-Part 3.Useofcoating, potting ormouldingforprotectionagainstpolution)

3 Terms and definitions

GB 4793.1 defined terms and definitions apply to this document.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 48 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 26802.2-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
48 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26802.2-2017

$650.00