GB/T 26716-2023Horology - Magnetic resistant watches (English PDF)
Also coversGBT26716-2023
Open the GB/T 26716-2023 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
August 6, 2023
Implementation date
March 1, 2024
Scope
GB/T 26716-2023 (Horology - Magnetic resistant watches) is available as an English-translated PDF.
GB/T 26716-2023 — This document specifies the technical requirements for antimagnetic watches, gives the markings that manufacturers are allowed to use, and describes the test methods for antimagnetic watches. This document applies to the design and testing of antimagnetic watches capable of withstanding everyday magnetic fields.
Document preview — GB/T 26716-2023
National Standard of the People's Republic of China
- ICS
- 39.040.10
- Classification
- Y 11
- Replacing
- GB/T 26716-2011
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative reference documents
- 3 Terms and definitions
- 4 requirements
- 4.1 General requirements
- 4.2 Requirements for mechanical watches
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents"
Drafting.
This document replaces GB/T 26716-2011 "Antimagnetic Watches and Clocks". Compared with GB/T 26716-2011, except for structural adjustment and compilation
In addition to editorial changes, the main technical changes are as follows.
a) Added the term and definition "enhanced anti-magnetic watch" and its requirements (see 3.2, 4.1);
b) The chapter "Significance" has been deleted (see Chapter 4 of the.2011 edition);
c) Added the calculation formula for the residual effect of mechanical watches after applying a magnetic field (see 4.2.2);
d) Added requirements for "other effects" for mechanical watches and electronic watches (see 4.2.3 and 4.3.2);
e) Changed the requirements for magnetic field intensity changes during the test in "Test Instruments" (see 5.2, 6.2 of the.2011 edition);
f) Added the demagnetization step in the antimagnetic test of mechanical watches (see 5.3.2.1.1);
g) The method of measuring the initial instantaneous daily difference of mechanical watches has been changed (see 5.3.2.1.3, 6.3.1 of the.2011 version);
h) Changed the method of antimagnetic test for mechanical watches (see 5.3.2.2, 6.3.2 of the.2011 edition);
i) Added "test procedures for electronic watches" (see 5.3.3);
j) The title and content of Appendix A have been changed (see Appendix A, Appendix A of the.2011 version).
This document is equivalent to ISO 764.2020 "Antimagnetic Watches and Clocks".
Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents.
1 Scope
This document specifies the technical requirements for antimagnetic watches, gives the markings that manufacturers are allowed to use, and describes the test methods for antimagnetic watches.
This document applies to the design and testing of antimagnetic watches capable of withstanding everyday magnetic fields.
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations
For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to
this document.
tions)
Note. GB/T 4028-2013 Inspection position marking of timing instruments (ISO 3158.1976, IDT)
3 Terms and definitions
The following terms and definitions apply to this document.
The terminology databases of ISO and IEC can be accessed at.
3.1
A watch that can withstand the uniform and continuous DC magnetic field of 4800 A/m encountered daily.
3.2
A watch that can withstand a uniform and continuous strong DC magnetic field of 16,000 amps per meter (A/m) and above at close range.
3.3
residualeffectresidualeffect
The difference between the instantaneous daily difference before and after the antimagnetic test.
4 requirements
4.1 General requirements
When a magnetic field of 4800A/m is applied, antimagnetic watches shall comply with the requirements of 4.2 or 4.3.Reinforced anti-magnetic watches shall comply with Appendix A
requirements.
4.2 Requirements for mechanical watches
4.2.1 Operating conditions of mechanical watches during application of a magnetic field
During the observation period the magnetic field is applied, the watch should not stop.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
How to Buy GB/T 26716-2023
- 1Add to cart. Click the "Buy GB/T 26716-2023" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 28593-2026 — Sand and dust weather warning levels
GB/T 19608.3-2026 — Classification of special environmental conditions - Part 3: Plateau
GB/T 47719-2026 — Micro-electromechanical systems (MEMS) technology - Test methods for the performance of MEMS capacitive microphones
Secure payment via Stripe
Payments accepted
GB/T 26716-2023
$245.00