Valid

GB/T 26716-2023Horology - Magnetic resistant watches (English PDF)

Also coversGBT26716-2023

Open the GB/T 26716-2023 preview as PDF

Preview — first pages of GB/T 26716-2023

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

August 6, 2023

Implementation date

March 1, 2024

Scope

GB/T 26716-2023 (Horology - Magnetic resistant watches) is available as an English-translated PDF.

GB/T 26716-2023 — This document specifies the technical requirements for antimagnetic watches, gives the markings that manufacturers are allowed to use, and describes the test methods for antimagnetic watches. This document applies to the design and testing of antimagnetic watches capable of withstanding everyday magnetic fields.

Document preview — GB/T 26716-2023

National Standard of the People's Republic of China

ICS
39.040.10
Classification
Y 11
Replacing
GB/T 26716-2011

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative reference documents
  • 3 Terms and definitions
  • 4 requirements
  • 4.1 General requirements
  • 4.2 Requirements for mechanical watches

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents"

Drafting.

This document replaces GB/T 26716-2011 "Antimagnetic Watches and Clocks". Compared with GB/T 26716-2011, except for structural adjustment and compilation

In addition to editorial changes, the main technical changes are as follows.

a) Added the term and definition "enhanced anti-magnetic watch" and its requirements (see 3.2, 4.1);

b) The chapter "Significance" has been deleted (see Chapter 4 of the.2011 edition);

c) Added the calculation formula for the residual effect of mechanical watches after applying a magnetic field (see 4.2.2);

d) Added requirements for "other effects" for mechanical watches and electronic watches (see 4.2.3 and 4.3.2);

e) Changed the requirements for magnetic field intensity changes during the test in "Test Instruments" (see 5.2, 6.2 of the.2011 edition);

f) Added the demagnetization step in the antimagnetic test of mechanical watches (see 5.3.2.1.1);

g) The method of measuring the initial instantaneous daily difference of mechanical watches has been changed (see 5.3.2.1.3, 6.3.1 of the.2011 version);

h) Changed the method of antimagnetic test for mechanical watches (see 5.3.2.2, 6.3.2 of the.2011 edition);

i) Added "test procedures for electronic watches" (see 5.3.3);

j) The title and content of Appendix A have been changed (see Appendix A, Appendix A of the.2011 version).

This document is equivalent to ISO 764.2020 "Antimagnetic Watches and Clocks".

Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents.

1 Scope

This document specifies the technical requirements for antimagnetic watches, gives the markings that manufacturers are allowed to use, and describes the test methods for antimagnetic watches.

This document applies to the design and testing of antimagnetic watches capable of withstanding everyday magnetic fields.

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations

For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to

this document.

tions)

Note. GB/T 4028-2013 Inspection position marking of timing instruments (ISO 3158.1976, IDT)

3 Terms and definitions

The following terms and definitions apply to this document.

The terminology databases of ISO and IEC can be accessed at.

3.1

A watch that can withstand the uniform and continuous DC magnetic field of 4800 A/m encountered daily.

3.2

A watch that can withstand a uniform and continuous strong DC magnetic field of 16,000 amps per meter (A/m) and above at close range.

3.3

residualeffectresidualeffect

The difference between the instantaneous daily difference before and after the antimagnetic test.

4 requirements

4.1 General requirements

When a magnetic field of 4800A/m is applied, antimagnetic watches shall comply with the requirements of 4.2 or 4.3.Reinforced anti-magnetic watches shall comply with Appendix A

requirements.

4.2 Requirements for mechanical watches

4.2.1 Operating conditions of mechanical watches during application of a magnetic field

During the observation period the magnetic field is applied, the watch should not stop.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

How to Buy GB/T 26716-2023

  1. 1Add to cart. Click the "Buy GB/T 26716-2023" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26716-2023

$245.00

$210.00for partners