GB/T 26196-2010Fireworks and firecrackers - Determination of carbon content in pyrotechnic compositions - High frequency-infrared absorption method (English PDF)

烟花爆竹 烟火药中碳含量的测定 高频-红外吸收法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 26196-2010 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

January 14, 2011

Implementation date

June 1, 2011

Scope

GB/T 26196-2010 is the English-translated version of 烟花爆竹 烟火药中碳含量的测定 高频-红外吸收法.

GB/T 26196-2010 lays down a high frequency-infrared absorption method for determining the carbon content of pyrotechnic compositions used in fireworks and firecrackers.

Clause 1 states that the standard applies to the determination of total carbon content in fireworks pyrotechnic compositions.

Before clause 1 the standard carries a warning: it is to be used by personnel with regular laboratory experience, it does not identify every possible safety problem, and because the compositions it covers are flammable and explosive dangerous goods it imposes three safety rules, namely that sample preparation be carried out under protective measures, that the quantity prepared and stored not exceed what the safety conditions allow, and that drying be done in a safe explosion-proof oven at a temperature not above 55 degrees Celsius.

Clause 3 gives the principle: the sample is burned in an oxygen stream in a high frequency induction furnace, the carbon dioxide produced is carried by the oxygen into the measuring cell of an infrared detector, and the instrument measures the absorption of infrared energy, from which the amount of carbon in the sample is calculated.

Clause 4 covers the instruments and materials, requiring usual laboratory equipment plus an infrared carbon and sulfur analyzer with a sensitivity of not less than 0.0001 per cent and a precision of 0.0002 per cent; Table 1 states the working conditions for a CS-902T high frequency infrared carbon and sulfur analyzer, including oxygen carrier gas of at least 99.9 per cent purity, an oxygen inlet pressure of 0.08 MPa, a power gas (nitrogen) pressure of 0.2 MPa to 0.3 MPa, an induction furnace power of 1.0 kW to 2.5 kW, a pressing time of 15 s to 20 s and an analysis time of 30 s to 60 s.

The normative references are GB/T 8170 on rules for expressing and rounding values and judging limiting values, and GB/T 15813-1995 on the separation and crushing of fireworks composition samples.

The standard was proposed by the China National Light Industry Council and is administered by the national fireworks standardization technical committee, SAC/TC 149. It was issued on 2011-01-14 and has applied since 2011-06-01.

Found what you need?

Document preview — GB/T 26196-2010

National Standard of the People's Republic of China

ICS
71.100.30
Classification
Y 88

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Principle
  • 4 Instruments and materials

Foreword

The standard proposed by China National Light Industry Council.

1 Scope

This standard specifies the high frequency - infrared absorption method with pyrotechnic fireworks carbon content approach.

This standard applies to fireworks pyrotechnic Determination of total carbon content.

2 Normative references

The following documents contain provisions which, through reference in this standard to become the standard terms. For dated references, all subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 8170 repair value expressed about the rules and limit values and judgment

GB/T 15813-1995 Fireworks forming agent sample separation and crushing

3 Principle

After heating the sample in a high frequency induction furnace combustion oxygen stream, the carbon dioxide produced from the oxygen carrier to an infrared detector measuring cell, the instrument Automatic measuring the absorption of infrared light energy can be calculated by the amount of carbon in the sample.

4 Instruments and materials

Usual laboratory equipment and the following. […]

4.1 Infrared carbon and sulfur analyzer

Under the selected instrument conditions were determined. Meet the following requirements, this method can be measured.

4.1.1 Sensitivity of not less than 0.0001%

4.1.2 precision should reach 0.0002%.

4.1.3 Instrument operating conditions. see Table 1 […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 26196-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26196-2010

$85.00