GB/T 25837-2010Qualification of electrical penetration assemblies in containment structures for nuclear power plants (English PDF)
核电厂安全壳电气贯穿件的质量鉴定
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25837-2010 in 30 minutes.
Issued by
AQSIQ; SAC
Level / Type
National · Recommended
Issue date
December 23, 2010
Implementation date
May 1, 2011
Scope
GB/T 25837-2010 is the English-translated version of 核电厂安全壳电气贯穿件的质量鉴定.
GB/T 25837-2010 is the Chinese standard "Qualification of electrical penetration assemblies in containment structures for nuclear power plants". Its scope clause reads: This standard specifies the test project for nuclear power plants EPAs adopted qualification, test methods, test conditions and acceptance Guidelines.
This standard applies to the specification with reference to the French RCC series designed and built pressurized water reactor nuclear power plants installed by containment, response guarantee Reactor plant signaling and power delivery between the internal and external electrical member through qualification.
The reference standards for other types of nuclear power plant containment electrical penetrations quality identification. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 25837-2010
National Standard of the People's Republic of China
- ICS
- 27.120.20
- Classification
- F 69
Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 2 Technical Specification
- 6 test program identification and qualification test procedures
- 7 containment electrical penetrations Functions and Classification
- 8 5 benchmark test
- 9 test under extreme conditions of use
- 12 fire resistance test
- 13 integrated test procedures and sequence table
- 14 qualification test records and reports
- Appendix A (informative) Voltage Rating - Current Rating - short-circuit current
- Annex B (informative) design basis accidents typical environmental conditions change curve
1 Scope
This standard specifies the test project for nuclear power plants EPAs adopted qualification, test methods, test conditions and acceptance
Guidelines.
This standard applies to the specification with reference to the French RCC series designed and built pressurized water reactor nuclear power plants installed by containment, response guarantee
Reactor plant signaling and power delivery between the internal and external electrical member through qualification.
The reference standards for other types of nuclear power plant containment electrical penetrations quality identification.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the edition are not applicable to the present file. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2421.1-2008 Environmental testing for electric and electronic products and Overview Guide
GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods - Test Db. Damp heat (12h
12h cycle)
GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal)
GB/T 2423.22-2002 Environmental testing for electric and electronic products Part 2. Test methods - Test N. Temperature change
GB/T 7354-2003 partial discharge measurement
Aging procedures and evaluation of test results. GB/T 11026.1-2003 heat resistance, electrical insulating materials - Part 1
GB/T 12727-2002 nuclear power plant safety systems of electrical equipment qualification
GB/T 13538-1992 nuclear power plant containment electrical penetrations
GB/T 13625-1992 nuclear power plant safety systems of electrical equipment seismic qualification
GB/T 18380.3-2001 Test methods for combustion bunched wires or cables
GB/T 18380.31-2008 burning test and optical fiber cables under fire conditions - Part 31. vertically mounted bunched wires
Cable vertical flame spread test test device
EJ/T 1197-2007 Nuclear power plant safety level of electrical equipment qualification test methods and environmental conditions
3 Terms and Definitions
GB/T 12727-2002 and established the following terms and definitions apply to this document.
3.1 Identification procedures
To provide certain equipment quality certification program.
3.2 Conditioning test conditions
The test samples were exposed to the test environment to determine the impact of these conditions on the test samples.
3.3 Pretreatment pre-conditioning
In order to eliminate or partially eliminate the test sample in response to previous experience, the processing done before the test samples in test conditions.
NB/T 20015 | EJ/T 306 | EJ/T 350 | GB/T 47509 | GB/T 47338 | GB/T 12789.1 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.4-2008Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
- GB/T 2423.10-2008Environmental testing - Part 2: Test methods - Test Fc: Vibration (sinusoidal)
- GB/T 2423.22-2002Environmental testing - Part 2: Test methods - Test N: Change of temperature
- GB/T 7354-2003High-voltage test techniques -- Partial discharge measurements
- GB/T 11026.1-2003Electrical insulating materials -- Thermal endurance properties -- Part 1: Ageing procedures and evaluation of test results
- GB/T 12727-2002Qualification of electrical equipment important to safety for nuclear power plants
GB/T 2421.1-2008 · GB/T 18380.3-2001
Similar standards
GB/T 12727|GB/T 13538|GB/T 13625|GB/T 7354|EJ/T 1197|GB/T 18380.3
How to Download GB/T 25837-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2423.4-2008 — Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
GB/T 47436-2026 — Smart community infrastructures - Smart transportation for newly developing areas
GB/T 47433-2026 — Smart community infrastructures - Smart transportation - Guidance for energy saving operation by optimization of operating speed
Secure payment via Stripe
Payments accepted
GB/T 25837-2010
$225.00