GB/T 25836-2010Rapid determination method of micro-hardness (English PDF)
微量硬度快速测定方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25836-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 23, 2010
Implementation date
May 1, 2011
Scope
GB/T 25836-2010 is the English-translated version of 微量硬度快速测定方法.
GB/T 25836-2010 is the Chinese standard "Rapid determination method of micro-hardness". Its scope clause reads: This standard specifies the demineralized water, H-type cation exchanger water, boiler feed water, condensate water determination in water samples with hardness.
This standard applies to the hardness of water samples (1 2Ca. Its clauses include and 1; method summary; reagents and instruments.
Found what you need?
Document preview — GB/T 25836-2010
National Standard of the People's Republic of China
- ICS
- 27.100
- Classification
- F 24
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 and 1
- 2 Normative references
- 3 Method Summary
- 4 Reagents and Instruments
1 Scope
This standard specifies the demineralized water, H-type cation exchanger water, boiler feed water, condensate water determination in water samples with hardness.
This standard applies to the hardness of water samples (1
2Ca
2 and 1
2Mg
2 meter) of 0.5µmol/L ~ 200µmol/L measured content.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6903 boiler water and cooling water General Analysis
GB/T 6907 boiler water and cooling water analysis water sample collection methods
3 Method Summary
At a pH of 10.0 ± 0.1 in the aqueous solution, a micro hardness indicator), ethylenediamine tetraacetic acid disodium salt (abbreviated EDTA) standard
Quasi titration solution was titrated to a blue end. According to the consumption volume of EDTA standard titration solution, the water sample can be calculated hardness values.
1) Trace hardness indicator is the trade name of products offered by the Xi'an Thermal Power Research Institute Co., Ltd.
Water samples iron content of less than 1.0mg/L, the copper content is less than 0.05mg/L on the determination without interference. When the iron content in water samples is greater than
1.0mg/L, the copper content greater than 0.05mg/L, the indicator may be preceded by 2mL of L- cysteine hydrochloride solution (10g/L) and
2mL triethanolamine solution (14) to conduct joint masking eliminate interference.
4 Reagents and Instruments
4.1
Purity of Reagents should be consistent with GB/T 6903 regulations.
4.2 Reagent water
Reagent II water level should be consistent with GB/T 6903 regulations.
4.3 Buret
when the hardness of the water content of less than 50.0µmol/L when using the smallest sub-scale of not more than 0.05mL microburette; when
When using the content of the water hardness of greater than or equal to 50.0µmol/L is the smallest sub-scale 0.1mL burette.
4.4
Sodium hydroxide solution (40g/L).
4.5
hydrochloric acid solution (14).
4.6 borax buffer solution
Weigh 40g borax (Na2B4O7 · 10H2O), 10g of sodium hydroxide dissolved in reagent water and dilute to
1L. Stored in plastic bottles.
4.7
Calcium standard solution [c1 = 0.1000mmol/L]. Weigh accurately under bake at 110 °C 2h and cooled in the dryer baseline calcium carbonate (CaCO3) 1.0009g, 15mL dissolved in hydrochloric acid solution (4.5) and quantitatively transferred to a 1L volumetric flask, dilute to volume with reagent water. again
This standard solution 10.00mL to draw 1L volumetric flask, mix, and dilute to volume with reagent water.
4.8 Micro Hardness indicator solution
Weigh Trace hardness indicator 2.0g, was added 5mL reagent water, stir, then add 80mL triethanolammonium
Amine and 15mL of anhydrous ethanol, stir, stored in brown bottles. Validity of <=30 days.
4.9 EDTA standard titration solution [c (EDTA) = 0.5mmol/L] preparation and calibration
GB/T 7595-2017 | DL/T 805.2-2016 | DL/T 911-2016 | GB/T 17623-2026 | GB/T 14416-2023 | GB/T 40589-2021 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 25836-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 25836-2010
$85.00