GB/T 25123.3-2011Electric traction -- Rotating electrical machines for rail and road vehicles -- Part 3: Determination of the total losses of convertor-fed alternating current motors by summation of the component losses (English PDF)

电力牵引 轨道机车车辆和公路车辆用旋转电机 第3部分:用损耗总和法确定变流器供电的交流电动机的总损耗

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for GB/T 25123.3-2011 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 30, 2011

Implementation date

June 1, 2012

Scope

GB/T 25123.3-2011 is the English-translated version of 电力牵引 轨道机车车辆和公路车辆用旋转电机 第3部分:用损耗总和法确定变流器供电的交流电动机的总损耗.

GB/T 25123.3-2011 — This Part of GB/T 25123 applies to machines that comply with GB/T 25123.2. The total losses of a convertor-fed motor may be determined by summation of the component losses derived from no-load and load tests.

The total input power is the sum of the power at the fundamental frequency and at all other frequencies.

In all practical cases the latter input includes the losses resulting from the voltage and current harmonics in the convertor supply by using suitable instrumentation it can be derived from measurement of the total and fundamental frequency power inputs when the machine is on load.

The losses supplied at the fundamental frequency cannot be measured directly and so are derived from measurement of the fundamental frequency load current and the fundamental frequency no-load power input.

Found what you need?

Document preview — GB/T 25123.3-2011

National Standard of the People's Republic of China

ICS
29.280
Classification
S 35

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Instrumentation...5
  • 3 Summation of losses...7
  • 3.1 The total losses are the sum of the following component losses...7
  • 3.2 Determination of the component losses...7
  • Annex A (informative) The equivalent circuit of an asynchronous motor...11
  • Annex B (informative) Stray load loss...19
  • Bibliography...21

Foreword

GB/T 25123 "Electric traction - Rotating electrical machines for rail and road vehicles"

consists of the following parts:

- Part 1: Machines others than electronic convertor-fed alternating current motors;

- Part 2: Electronic convertor-fed alternating current motors;

- Part 3: Determination of the total losses of convertor-fed alternating current motors

by summation of the component losses.

This Part is Part 3 of GB/T 25123.

This Part was drafted in accordance with the rules given in GB/T 1.1-2009.

This Part uses redrafting method to modify and adopt IEC 60349-3:1995 "Electric

traction - Rotating electrical machines for rail and road vehicles - Part 3: Determination

of the total losses of convertor-fed alternating current motors by summation of the

component losses".

This Part made the following editorial changes:

- According to the requirements of GB/T 1.1-2009, the formula numbers (1)~(8) of

IEC 60349-3:1995 are numbered as (A.1)~(A.9) in this Part. Add numbers to the

formulas in 3.2.1.2 and Annex B;

- Correct the following errors in Table A.2 of the original text:

a) In the formula of item 15, "(1)/(7)" in the original text is changed to "1/(7)";

b) In the formula of item 19, "(17)-(18)" in the original text is changed to

"(17)+(18)";

c) In the formula of item 24, "(23)/(2)" in the original text is changed to "(23)+(2)";

d) In the formula of item 27, "(22)2" in the original text is changed to "(22)".

This Part was proposed by Ministry of Railways of the People's Republic of China.

This Part shall be under the jurisdiction of National Technical Committee on Traction

Electrical Equipment and Systems of Standardization Administration of China

(SAC/TC 278).

Main drafting organizations of this Part: Zhuzhou CSR Times Electric Co., Ltd.

The drafting organizations of this Part: CSR Zhuzhou Electric Co., Ltd. and Yongji

Xinshisu Electric Co., Ltd.

Electric traction - Rotating electrical machines for rail and

road vehicles - Part 3: Determination of the total losses of

convertor-fed alternating current motors by summation of

the component losses

1 Scope

This Part of GB/T 25123 applies to machines that comply with GB/T 25123.2.

The total losses of a convertor-fed motor may be determined by summation of the

component losses derived from no-load and load tests. The total input power is the sum

of the power at the fundamental frequency and at all other frequencies. In all practical

cases the latter input includes the losses resulting from the voltage and current

harmonics in the convertor supply by using suitable instrumentation it can be derived

from measurement of the total and fundamental frequency power inputs when the

machine is on load.

The losses supplied at the fundamental frequency cannot be measured directly and so

are derived from measurement of the fundamental frequency load current and the

fundamental frequency no-load power input.

2 Instrumentation

The extra loss due to operation on a convertor supply is obtained from the difference of

the total and fundamental frequency power input on load.

The power inputs shall be measured simultaneously on each phase by a digital sampling

instrument. Measurement on all three phases is preferred but the two wattmeter method

is permissible as an alternative.

The total power is obtained from the product of voltage and current over a period of

time and the fundamental power from a Fourier transform using the same sampling.

It is necessary to consider the accuracy of the whole instrument chain considering both

amplification and phase shift errors over the desired frequency range. As the power

factor of the harmonics is generally very low (less than 0.l for voltage imposed

asynchronous systems) particular attention is drawn to the need for minimum phase

angle errors.

fully established by experience. Additional information may be obtained by carrying out a low

power test described in Annex B.

3.2.1.3 Losses supplied at other than the fundamental frequency

The losses arising from the supply harmonics are the difference between the total and

fundamental frequency power inputs to the motor when on load with the stator windings

at approximately the temperature of reference.

NOTE: If the convertor is a voltage source type and its modulation pattern is independent of load,

the difference may be measured on no-load.

3.2.2 Synchronous motors
3.2.2.1 No-load losses supplied at the fundamental frequency

The motor shall be driven on open circuit by a calibrated machine at the speed for which

the losses are being determined and shall be excited by an independent source to

generate the voltage shown on the specified characteristic at the same speed. The losses

are equal to the mechanical power input to the motor shaft.

3.2.2.2 Load dependent losses supplied at the fundamental frequency

The fundamental frequency I2R losses in the stator shall be calculated from the

fundamental frequency current in each winding at the point for which the losses are

being determined and from the measured resistance of the winding corrected to the

temperature of reference.

Unless otherwise specified, the additional load losses shall be determined by driving

the machine with the stator windings short-circuited at the speed of the point on the

specified characteristic for which the losses are being determined. The excitation shall

be adjusted to give the fundamental frequency stator winding currents for the same

point. The losses shall be taken as the power supplied to the machine shaft less the sum

of the total stator I2R losses and the power supplied when the machine is driven

unexcited at the same speed.

3.2.2.3 Losses supplied at other than the fundamental frequency

The losses arising from the supply harmonics are the difference between the total and

fundamental frequency power inputs to the motor when on load with the windings at

approximately the temperature of reference.

3.2.2.4 Loss in the excitation circuit

The loss in the excitation circuit shall be the product of the current in the winding and

the total excitation voltage at the point for which the losses are being determined. The

voltage shall be the value required to supply the excitation current with the winding at

the temperature of reference. Account shall be taken of any ripple in the excitation

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

How to Download GB/T 25123.3-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 25123.3-2011

$185.00