Valid

GB/T 23362.1-2009Methods for chemical analysis of high purity indium hydroxide - Part 1: Determination of arsenic content - Atomic fluorescence spectrometry (English PDF)

高纯氢氧化铟化学分析方法 第1部分:砷量的测定 原子荧光光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 23362.1-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 19, 2009

Implementation date

January 1, 2010

Scope

GB/T 23362.1-2009 is the English-translated version of 高纯氢氧化铟化学分析方法 第1部分:砷量的测定 原子荧光光谱法.

GB/T 23362.1-2009 is the Chinese standard "Methods for chemical analysis of high purity indium hydroxide - Part 1: Determination of arsenic content - Atomic fluorescence spectrometry".

Its scope clause reads: This section GB/T 23362 specifies the determination method of high-purity indium hydroxide arsenic content. This section applies to the determination of high-purity indium hydroxide in the amount of arsenic, measurement range (mass fraction) of 0.00001% to 0.0050%. Its clauses include method summary; reagents; instrument.

Found what you need?

Document preview — GB/T 23362.1-2009

National Standard of the People's Republic of China

ICS
77.120
Classification
H 66

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument

1 Scope

This section GB/T 23362 specifies the determination method of high-purity indium hydroxide arsenic content.

This section applies to the determination of high-purity indium hydroxide in the amount of arsenic, measurement range (mass fraction) of 0.00001% to 0.0050%.

2 Method summary

Hydrochloric acid, hydrobromic acid solution, hydrazine sulfate arsenic is pre-reduced by distillation, absorption of condensed water. In hydride generator, the trivalent arsenic is

Potassium borohydride as hydride reduction, with argon gas introduced into the quartz furnace atomizer, the fluorescence intensity measured on the atomic fluorescence spectrometer, calculated

Arsenic content.

3 Reagents

Unless otherwise stated, use only identified as gifted class pure reagents and secondary distilled water or equivalent to its purity.

3.1

hydrochloride (rho1.19g/mL).

3.2

hydrobromide (rho1.49g/mL), after the use of distillation.

3.3

hydrazine sulfate.

3.4 solution of potassium borohydride (20g/L)

Weigh 10g potassium borohydride, dissolved in 500mL of potassium hydroxide solution (5g/L), and mix well. If the

A precipitate is filtered and used. The time is now equipped with.

3.5

hydrochloric acid (1 + 19).

3.6 arsenic standard stock solution

Weigh 0.1320g pre-dried at 105 °C 1h arsenic trioxide (mass fraction >=99.99%), home

In 300mL beaker, add 15mL of hydrochloric acid (3.1) and 5mL nitric acid (rho1.42g/mL), heated and dissolved, evaporated to near dryness. Add 100mL

Hydrochloric acid (3.1) dissolved salts, cooled and transferred to 1000mL volumetric flask, dilute with water to volume, and mix. This solution containing 1mL

100µg arsenic.

3.7

arsenic standard solution A. Pipette 10.00mL arsenic standard stock solution (3.6), placed in 200mL volumetric flask, dilute to the mark,

Mix well. This solution 1mL containing 5µg arsenic.

3.8 arsenic standard solution B

Pipette 10.00mL arsenic standard solution A (3.7), placed in 100mL volumetric flask, dilute to the mark with water, mix uniform. This solution 1mL containing 500ng arsenic.

3.9 arsenic standard solution C

Pipette 10.00mL arsenic standard solution B (3.8), a 50mL volumetric flask, dilute with water to volume, and mix.

This solution 1mL containing 100ng arsenic.

3.10

argon (volume fraction >=99.99%).

4 Instrument

4.1

Distillation generator.

4.2

atomic fluorescence spectrometer, equipped with a special arsenic hollow cathode lamp. Atomic fluorescence spectrometer should meet the following specifications.

--- Stability. Zero drift <=5%, short-term stability RSD<=3% 30min inside;

--- The detection limit <=0.5ng/mL;

--- Linear curve. the curve in 0 ~ 50ng/mL range, the correlation coefficient should >=0.995.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 23362.1-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 23362.1-2009

$85.00