Valid

GB/T 23273.6-2009Methods for chemical analysis of cobalt oxalate - Part 6: Determination of chlorine ion content - Ion selective electrode method (English PDF)

草酸钴化学分析方法 第6部分:氯离子量的测定 离子选择性电极法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 23273.6-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

January 5, 2009

Implementation date

November 1, 2009

Scope

GB/T 23273.6-2009 is the English-translated version of 草酸钴化学分析方法 第6部分:氯离子量的测定 离子选择性电极法.

GB/T 23273.6-2009 is the Chinese standard "Methods for chemical analysis of cobalt oxalate - Part 6: Determination of chlorine ion content - Ion selective electrode method".

Its scope clause reads: GB/T 23273 provisions of this part of the determination of cobalt oxalate in a water-soluble chloride ion content. This section applies to the determination of water-soluble chloride ions in an amount of cobalt oxalate.

Measurement range. 0.015% to 0.5%. Its clauses include method summary; reagents; instrument.

Found what you need?

Document preview — GB/T 23273.6-2009

National Standard of the People's Republic of China

ICS
77.120.70
Classification
H 13

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument

1 Scope

GB/T 23273 provisions of this part of the determination of cobalt oxalate in a water-soluble chloride ion content.

This section applies to the determination of water-soluble chloride ions in an amount of cobalt oxalate. Measurement range. 0.015% to 0.5%.

2 Method summary

Water is heated in a sample leaching of chloride ions in the ionic strength modifiers presence of sodium, chlorine ion selective electrode as indicator electrode

And corresponding reference electrode as a reference, potentiometric measuring electrode measured by its potential value. Within the measurement range, the electrode potential and the chlorine ion concentration

Negative logarithm linear relationship according to the standard curve method to calculate the amount of chlorine ions.

3 Reagents

Analysis of water are freshly prepared twice-distilled water.

3.1

sodium nitrite solution (5mol/L).

3.2

Chloride standard stock solution.

Weigh 0.1649g sodium chloride (reference reagent, pre-burning after 550 °C to constant weight in a desiccator and cooled to room temperature) is placed

150mL beaker, dissolved in water and transferred to 100mL volumetric flask, constant volume of water. 1mL 1mg solution containing chloride ions.

Chloride Standard Solution 3.3.

Chloride standard solution. Pipette 20.00mL chloride stock solution (3.2) in 200mL flask, constant volume of water. This solution

1mL containing 0.1mg chloride ions.

4 Instrument

Potential of 4.1 meter, with a stirring device.

4.2

Chloride Ion Selective Electrode require chloride ion concentration in the solution is at least 10-1mol/L ~ 10-4mol/L range, the electrode potential and chlorine

Negative logarithm of the ion concentration was linear.

4.3 reference electrode

Electrode selection in accordance with manufacturer's instructions manual.

4.4

heatable magnetic stirrer.

Step 5 Analysis

5.1 Sample

Weigh 2.000g sample (m1 0), accurate to 0.0001g.

5.2 Determination

5.2.1

The sample (5.1) into 250mL beaker, add about 35mL of water, stir bar, the beaker was placed in a heatable magnetic stir

After the stirrer (4.4), the mixture was stirred and heated to boiling continued 5min, removed, cooled to room temperature, the solution was as shown in Table 1 together with the insoluble matter was transferred to the corresponding flask

In Table 1 was added sodium nitrite solution (3.1) with water to volume, measured.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 23273.6-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 23273.6-2009