Valid

GB/T 22934-2008Glass containers -- Resistance to vertical load -- Test method (English PDF)

玻璃容器 耐垂直负荷试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (3 pages)

Need quotation for your management?

Get a formal quotation for GB/T 22934-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

December 30, 2008

Implementation date

September 1, 2009

Scope

GB/T 22934-2008 is the English-translated version of 玻璃容器 耐垂直负荷试验方法.

GB/T 22934-2008 — This standard specifies the method for determination of glass containers bear the additional vertical force.

Found what you need?

Document preview — GB/T 22934-2008

National Standard of the People's Republic of China

ICS
55.100
Classification
Y 22

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Sampling
  • 3 Devices
  • 4 Test Procedure
  • 5 Safety requirements

Foreword

This standard is identical with ISO 8113:2004 "Vertical load test method for Resistance of Glass Containers" (in English).

This standard is equivalent translation ISO 8113:2004.

For ease of use, this standard made the following editorial changes.

a) "this International Standard" be replaced by "this standard";

b) Remove the preface international standards;

c) increasing the preface of this standard.

The standard proposed by China National Light Industry Council.

This standard by the National Standardization Technical Committee household glass (SAC/TC377) centralized.

This standard was drafted. Donghua University, the National Optical glass enamels Quality Supervision and Inspection Center.

1 Scope

This standard specifies the method for determination of glass containers bear the additional vertical force.

2 Sampling

According to a predetermined number of containers tested.

A container for the test should not be subjected to mechanical tests or any other tests adversely affect the heat resistance of their vertical load.

3 Devices

3.1 pressure meter or other suitable device includes the following features.

3.1.1 The device should have the ability to continue to increase the desired pressure, and the recording apparatus using a pointer or display this pressure, the precision of at least 2.5%.

3.1.2 by means of two horizontal flat steel plate components. Flat top should be able to regulate their own level, flat surface of the center of the bottom it should be labeled.

3.1.3 device should be configured shield, or should be configured sufficiently strong cylindrical shield for each type of test vessel, shield high it should be slightly lower than the height of the test sample.

3.2 gasket, for example. several layers of paper or card stock, in order to prevent the glass to metal contact under load.

To obtain a stable load, and prevent contact between the glass and the metal, spacers, such as. a plastic sheet or a rubber sheet, paper folding, Card stock or caps should be inserted between the glass surface and the metal surface pressure.

4 Test Procedure

4.1 sample temperature and ambient temperature difference should not exceed 5 °C.

4.2 particular attention to ensure no plate glass particles. Place a base gasket (3.2) at the bottom center of the plate, put the test vessel Thereon. Center test vessel should be consistent with the center of the device.

4.3 with a shield to protect the test vessel, at the same time, if the test specified in the mouth portion of the container sealing surface placed on its consistent seal thereof. In addition to making with sealing compound outside, covering a test vessel and placed at the bottom of the same base gasket on the test container. You can use either paper Sealing compound can also be used, for the replacement of the test vessel on each test, the lower pad.

Note. consistent sealing compound is suitable for use, especially when using a metal seal with a sealing compound layer, in these cases, the application manually spiral and bayonet lock sealing compound.

The average advance rate or a rate constant of 4.4 increase in pressure, and should be recorded.

4.5 The following tests conducted in accordance with the purpose and the type of test.

4.5.1 Test

Increasing the pressure to a predetermined value. When it reaches a predetermined value, it should remove the plate. After the test container according to the number of pre-defined test, trial Inspection is completed.

4.5.2 Full escalation trial

Gradually increase the pressure until the test container rupture. All test sample containers are required to be tested.

5 Safety requirements

If the operator does not carry out proper protection during the test may damage the body. The test shall be carried out under the recommended security methods.

GB/T 22934-2008/ISO 8113:2004

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 3 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 22934-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
3 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 22934-2008

$50.00