GB/T 22689-2008Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges (English PDF)
测定固体绝缘材料相对耐表面放电击穿能力的推荐试验方法
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB/T 22689-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 31, 2008
Implementation date
November 1, 2009
Scope
GB/T 22689-2008 is the English-translated version of 测定固体绝缘材料相对耐表面放电击穿能力的推荐试验方法.
GB/T 22689-2008 — This standard specifies the relative resistance of solid insulating material surface of the test method for the ability to discharge breakdown.
This standard applies to the ability to assess the relative resistance of solid insulating materials breakdown when exposed to surface discharge.
Found what you need?
Document preview — GB/T 22689-2008
National Standard of the People's Republic of China
- ICS
- 29.035.99
- Classification
- K 15
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 4 Test device
- 4.1 Test electrode
Foreword
This standard is identical with IEC 60343:1991 (2nd edition) "Determination solid insulating materials are relatively resistant to breakdown by surface discharges recommended test Test method "(in English).
This standard is technically and IEC 60343:1991 (2nd edition) agreement, only made the following editorial changes.
--- Remove the IEC 60343:1991 foreword and introduction, preface to increase national standards;
"." --- With a decimal point instead of a comma as the decimal point, "";
--- In the second chapter of normative references, the IEC 60212. 1971 is rewritten as GB/T 10580-2003.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Electrical insulation materials and insulation systems assessment Standardization Technical Committee (SAC/TC301) centralized.
This standard was drafted. Guilin Electric Institute of Science, Technology Electrical Machinery Industry Beijing Institute of Economic Research.
1 Scope
This standard specifies the relative resistance of solid insulating material surface of the test method for the ability to discharge breakdown.
This standard applies to the ability to assess the relative resistance of solid insulating materials breakdown when exposed to surface discharge.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 7354-2003 partial discharge measurements (IEC 60270:2000, IDT) GB/T 10580-2003 standard conditions of solid insulating material before the test and during the test used (IEC 60212. 1971, IDT) GB/T 16927 (all parts) high-voltage test techniques (eqv IEC 60060-1, IEC 60060-2) Principle 3 when the solid insulating material is exposed to industrial frequency electric field is generated in the surface discharge, we need to have some simple method to evaluate Given its relative resistance to breakdown and surface discharge capacity.
Experience has shown that, during the test, if around the electrode and the surface of the sample is passed through air drying cycle, use several different types of electrodes Generating surface discharge, and complete breakdown of the material as a criterion durability test, similar to the material relating to such stress can be obtained while repeating the classification.
4 Test device
4.1 Test electrode
The test shall use a stainless steel cylindrical electrode and a flat electrode. Stainless steel electrode should meet the following requirements.
4.1.1 Cylindrical electrode
6mm ± 0.3mm diameter cylindrical body, down to the edge of a circular arc of radius 1mm. The quality of the electrode is not more than 30g, and it should be placed perpendicular to the sample surface. For soft material, in order to prevent mechanical damage that may occur between the electrode and the sample allowed to have no more than a Over 100µm gap.
For thin samples (thickness of less than 100µm), more convenient approach is to be placed between the two electrodes fixed pitch of 100µm.
When it is necessary to use small samples to reduce heat capacitance, allowing the use of less than 6mm diameter cylindrical electrode, the electrode edges down into 1mm radius arc.
Figure 1 is an example of two electrode means may be employed. When the inter-electrode gap and the sample does not need to be used as shown in Figure 1b) in
Electrode means to prevent the occurrence of slight inclination, any other suitable means.
4.1.2 Plate electrodes
Area flat electrodes should be larger than the area of \u200b\u200bthe cylinder at the test voltage discharge electrode covered.
4.1.3 Electrode means
Electrode means should have axial symmetry. Location where the air intake should meet the various electrodes have a uniform air distribution as possible in order to maintain Permit reproducible results. On top of one sample can be used to test one or more electrodes. If a plurality of electrodes, electrode spacing should GB/T 22689-2008/IEC 60343:1991
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 7354-2003High-voltage test techniques -- Partial discharge measurements
- GB/T 10580-2003Standard conditions for use prior to and during the testing of solid electrical insulating materials
IEC 60270 · IEC 60212 · GB/T 16927 · IEC 60060
How to Download GB/T 22689-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16927.1-2011 — High-voltage test techniques -- Part 1: General definitions and test requirements
GB/T 16927.2-2013 — High-voltage test techniques -- Part 2: Measuring systems
GB/T 16927.3-2010 — High voltage test techniques -- Part 3: Definitions and requirements for on-site testing
Secure payment via Stripe
Payments accepted
GB/T 22689-2008