Scope
GB/T 22383-2017 (Rigid gas-insulated transmission lines for rated voltage of 72.5 kV and above) is available as an English-translated PDF.
GB/T 22383-2017 — This standard specifies the rated voltage of 72.5kV and above, the rated frequency of 50Hz rigid gas insulated transmission line (GIL) so that the requirements for condition, rating, design and construction, and test, etc., are at least partially insulated by air at different pressures from atmospheric pressure Non-corrosive insulation gas to achieve.
This standard applies in addition to GB/T 7674-2008 applications, but also can be used in the provisions of GB/T 7674-2008 not covered Occasion (see note 3).
Rigid gas-insulated transmission line at each end, you can use special components it and other equipment (such as casing, power transformers or reactance Devices, cable terminations, metal-enclosed surge arresters, voltage transformers or GIS) covered by their respective technical standards.
Unless otherwise specified, rigid gas insulated transmission lines shall be designed for normal service conditions. Note 1. In this standard, the term "rigid gas insulated transmission line" is abbreviated as "GIL".
Note 2. In this standard, the term "gas" means single gas or mixed gas, as determined by the manufacturer. Note 3.
The application of GIL is as follows. --- All or part of the rigid gas insulated transmission line directly buried underground (buried); --- Rigid gas insulated transmission line installation sites, all or part of the public accessible areas; Rigid gas insulated transmission lines are long and the length of a typical gas compartment exceeds the normal length of a GIS compartment.
Found what you need?
Document preview — GB/T 22383-2017
National Standard of the People's Republic of China
- ICS
- 29.240.20
- Classification
- K 43
- Replacing
- GB/T 22383-2008
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword V.
- 1 Scope
- 1.1 Scope
- 1.2 Normative references
- 2 Normal and special conditions of use
- 2.1 Overview
- 2.101 Open the device in the air
- 2.102 Buried equipment
- 2.103 Tunnels, shafts and similar equipment
- 3 Terms and definitions
- 4 Rating
- 4.1 Overview
- 4.2 Rated voltage (Ur)
- 4.3 Rated insulation level
- 4.4 Rated frequency (fr)
- 4.5 Rated current and temperature rise
- 4.6 Rated short-time withstand current (Ik)
- 4.7 Rated peak withstand current (Ip)
- 4.8 Rated short circuit duration (tk)
- 4.9 Auxiliary, control circuit rated supply voltage (Ua)
- 4.10 Auxiliary circuit rated power frequency
- 4.11 Controlled pressure system with compressed air source rated pressure
- 4.12 Insulation and/or opening and closing with the rated charge level
- 5 Design and Structure
- 5.1 Overview
- 5.2 GIL gas requirements
- 5.3 Ground
- 5.4 Auxiliary and control equipment
- 5.5 Power operation
- 5.6 Energy storage operation
- 5.7 Labor-independent or power-independent operation (non-locking operation)
- 5.8 Release operation
- 5.9 Low pressure and high pressure lockout and monitoring device
- 5.10 Nameplate
- 5.11 Interlocking device
- 5.12 Position instructions
- 5.13 Degree of protection provided by enclosure
- 5.14 Creepage distance
- 5.15 Gas and vacuum seals
- 5.16 Liquid seal
- 5.17 Fire hazard (flammability)
- 5.18 Electromagnetic compatibility (EMC)
- 5.19 X-ray emission
- 5.20 Corrosion
- 5.101 Internal fault
- 5.102 Housing
- 5.103 Partitions and compartments
- Section 5.104 GIL System
- 5.105 Pressure Release
- 5.106 Thermal expansion compensation
- 5.107 External vibration
- 5.108 Non-buried GIL stent
- 6 Type test
- 6.1 General
- 6.2 Insulation test
- 6.3 Radio interference voltage (riv) test
- 6.4 Loop resistance measurement
- 6.5 Temperature rise test
- 6.6 Short-time withstand current and peak withstand current test
- 6.7 Degree of protection verification
- 6.8 Seal Test
- 6.9 Electromagnetic compatibility test (EMC)
- 6.10 Additional Tests for Auxiliary and Control Circuits
- 6.11 Vacuum interrupter X-ray test procedures
- 6.101 Case Verification Test
- 6.102 Partition pressure test
- 6.103 Buried equipment corrosion test
- 6.104 Special mechanical test of sliding contact
- 6.105 Internal Fault Causes Tests Under Arc Conditions
- 6.106 Climate protection test
- 7 Factory test
- 7.1 Overview
- 7.2 Main circuit insulation test
- 7.3 Auxiliary and control circuit insulation test
- 7.4 The main loop resistance measurement
- 7.5 Seal Test
- 7.6 Design and Visual Inspection
- 7.101 Partial discharge measurement
- 7.102 Pressure test of factory manufactured enclosure
- 7.103 Partition pressure test
- 8 GIL Selection Guide
- 8.101 Overview
- 8.102 Short-term overload capacity
- 8.103 Forced cooling
- 9 Inquiries, bidding and ordering information provided
- 9.1 Overview
- 9.2 Inquiry List and Order Information
- 9.3 Tender Information
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 22383-2008 "Rated voltage 72.5kV and above rigid gas insulated transmission line" and GB/T 22383-2008 compared to the main technical changes are as follows.
--- Increased air tightness and anti-corrosion protection requirements;
--- Added 3.111 isolation unit, 3.113GIL segment;
--- Increased 4.3 preferred rated insulation level Table 1 and Table 2, and some of the insulation level has been adjusted;
--- Remove the 5.1 switchgear and control equipment in the liquid requirements;
--- Removed the 5.10.101 measurement mark, 5.10.103 public signs;
--- Increased 5.20.102 non-buried corrosion protection equipment;
--- Increased 5.101.2 in Table 4, according to the performance of the protection system to determine the performance of different arc duration;
--- Added 5.104GIL system of the sub-paragraph;
--- 6.1 increased by the normal production of products every eight years should be carried out pilot projects;
--- 6.2 insulation test voltage adjustment test;
--- Adjust 6.102 diaphragm pressure test pressure rise rate;
--- Added 7.1 Overview and pilot projects;
--- 7.102.2 on-site shell welding and other pilot projects adjusted to 10.4.104, the 7.104 buried equipment corrosion test adjustment is 10.4.107;
--- In 7.102 increased the duration of the test and test criteria;
--- Chapter 8 Selection Guide increased the short-term overload capacity and forced cooling requirements;
--- Added 11.2 manufacturer's precautionary measures and 11.3 user's precautionary measures;
--- Increase the Chapter 12 product impact on the environment;
--- Appendix B B.10.1 three-phase GIL, B.10.2 single-phase GIL, B.10.2.1 fixed connection, B.10.2.2 special connection, B.10.2.2.1 Single-point connection merged into an overview, leaving only B.10.2.2.2 cross-connect;
--- Removed Appendix D, with reference to Appendix B GB/T 7674-2008.
This standard uses redrafted Law Amendment uses IEC 62271-204:2011 "high-voltage switchgear and control equipment Part 204. Amount Constant voltage 52kV rigid gas insulated transmission line. " the technical differences between this standard and IEC 62271-204:2011 and the reasons are as follows.
--- On normative references, this standard made a technical difference with the adjustment to adapt to China's technical conditions, adjust the situation Concentration reflected in the 1.2 "Normative references", the specific adjustments are as follows.
- Equivalent with the international standard GB/T 2421.1 instead of IEC 60068-1;
- Replaced IEC 60050-441:1984 with GB/T 2900.20-2016 modified to adopt international standards;
- Replaced IEC 60050-151 with GB/T 2900.83 modified to adopt international standards;
- Equivalent with the international standard GB/T 4208-2017 replaced IEC 60529:2013;
- Equivalent with the international standard GB/T 7354 instead of IEC 60270;
- Replaced IEC 62271-203:2011 with GB/T 7674-2008 modified to adopt international standards;
- Replaced IEC 60480 with GB/T 8905 modified to adopt international standards;
- Replaced IEC 62271-1:2007 with GB/T 11022-2011 modified to adopt international standards;
- GB/T 16927.1 modified to adopt international standards instead of IEC 60060-1;
- Replacing IEC 62271-303 with GB/T 28537 modified to use international standards;
- increase the reference GB/T 12022;
- Remove references IEC 60287-3-1.995, IEC 60376, ISO/IEC Guide51.
--- The operating frequency of 60Hz and below to the rated frequency of 50Hz;
--- Rated voltage. Removed the rated voltage has nothing to do with China's power grid, in accordance with the voltage listed in GB/T 11022-2011 Given
--- Increased 4.3 preferred rated insulation level Table 1 and Table 2, and some of the insulation level has been adjusted;
--- The rated short-circuit duration of the standard value from 1s to 2s;
--- Remove 5.13.101 of the main circuit protection and 5.13.102 degree of protection of the auxiliary circuit;
--- Increased 5.101.2 in Table 4, according to the performance of the protection system to determine the performance of different arc duration;
--- 6.1 increased the normal production of products every eight years should be carried out pilot projects;
--- 6.2.7.2 thunder and lightning surge voltage test is modified to 6.2.8.3 surge voltage test and 6.2.8.4 lightning impulse test Pressure test (consistent with GB/T 11022-2011);
--- 6.2.10 partial discharge test to be modified, the test procedures and GB/T 7674-2008 requirements;
--- Adjust 6.102 diaphragm pressure test pressure rise rate;
--- Added 7.1 Overview and pilot projects;
--- 7.102 increased test duration and test criteria;
--- Increased pressure test 7.103 clapboard;
--- Due to the structural differences between national standards and international standards, this standard was drafted for the international standard part of the original suspension of the added section Paragraph number, resulting in some of the provisions of the subsequent changes.
This standard proposed by the China Electrical Equipment Industry Association.
This standard by the National High Voltage Switchgear Standardization Technical Committee (SAC/TC65) centralized.
This standard was drafted unit. High Group Co., Ltd., Xi'an High Voltage Apparatus Research Institute Co., Ltd., China Electric Power Research Institute, West Anxi Electric Switchgear Co., Ltd., Shanghai Xidian High Voltage Switchgear Co., Ltd., Xi'an West High Voltage Switchgear Co., Ltd., ABB (China) Limited liability company, machinery and industrial high-voltage electrical equipment quality testing center, Xiamen ABB High Voltage Switchgear Co., Ltd., the new high Northeast Electric Group Pressure Switch Co., Ltd., Zhejiang Shintong Electric Manufacturing Co., Ltd., Jinhua Power Company, Huayi Electric Co., Ltd., TBEA Shenyang Electric Gas Technology Research Institute Co., Ltd., Beijing Beikai Electric Co., Ltd., Zhejiang Switchgear Co., Ltd., TBEA in Shanghai high-pressure open Off Co., Ltd., Shandong Taikai High Voltage Switchgear Co., Ltd., Henan Senyuan Electric Co., Ltd., Yihe Electric Group Co., Ltd.
The drafters of this standard. Yan Guanxing, Zhou Hua, Wang Xiang Ke, Tian Enwen, Tian Gang collar, Han Shumo, Zhong Jianying, Zhang Jinbo, Wu Hongyan, Feng Wujun, Zhang Zixiao, Zhong Lei, Lin Lin, Yan Zhanzheng, Zhang Youpeng, Cui Boyuan, Hou Pingyin, Zhao Bo-nan, Li Zhi-bo, Li Zhenjun, Li Jianhua, Wang Chuanchuan, Road full peak, Wei Yang, Chen sent, Xu Xiuming, Yang Yingjie, Li Bao, Gao Erping, Wu Wenhai, Zhang Meng, Ye Shuxin, Lutheran, Tian Xiaoyue, Pan Shiyan, Zhang Shu, Yin Hongyan, Sun Rongchun, Chen Borong, Zhou Qingqing, Shi Pengbin, Wang Jiancheng, Liu Yang, Kong Xiangchong, Wei Kai.
This standard replaces the standards previously issued as.
--- GB/T 22383-2008.
Rated voltage 72.5kV and above rigidity Gas insulated transmission line
1 Scope
1.1 Scope
This standard specifies the rated voltage of 72.5kV and above, the rated frequency of 50Hz rigid gas insulated transmission line (GIL) so that the requirements for condition, rating, design and construction, and test, etc., are at least partially insulated by air at different pressures from atmospheric pressure Non-corrosive insulation gas to achieve.
This standard applies in addition to GB/T 7674-2008 applications, but also can be used in the provisions of GB/T 7674-2008 not covered Occasion (see note 3).
Rigid gas-insulated transmission line at each end, you can use special components it and other equipment (such as casing, power transformers or reactance Devices, cable terminations, metal-enclosed surge arresters, voltage transformers or GIS) covered by their respective technical standards.
Unless otherwise specified, rigid gas insulated transmission lines shall be designed for normal service conditions.
Note 1. In this standard, the term "rigid gas insulated transmission line" is abbreviated as "GIL".
Note 2. In this standard, the term "gas" means single gas or mixed gas, as determined by the manufacturer.
Note 3. The application of GIL is as follows.
--- All or part of the rigid gas insulated transmission line directly buried underground (buried);
--- Rigid gas insulated transmission line installation sites, all or part of the public accessible areas;
Rigid gas insulated transmission lines are long and the length of a typical gas compartment exceeds the normal length of a GIS compartment.
1.2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2421.1 Electrical and Electronic Products Environmental Testing Overview and Guidelines (GB/T 2421.1-2008, IEC 60068-1:1988, IDT) GB/T 2900.20-2016 Electrotechnical terminology High-voltage switchgear and control equipment [IEC 60050 (441) .1984, MOD] GB/T 2900.83 Electrotechnical terminology Electrical and magnetic devices (GB/T 2900.83-2008, IEC 60050-151:2001, IDT) GB/T 4208-2017 Enclosure Rating (IP Code) (IEC 60529:2013, IDT) GB/T 7354 partial discharge measurement (GB/T 7354-2003, IEC 60270:2000, IDT) Gas - insulated metal - enclosed switchgear with rated voltages up to 72.5 kV (IEC 62271-203).
2003, MOD)
GB/T 8905 sulfur hexafluoride electrical equipment gas management and testing guidelines (GB/T 8905-2012, IEC 60480:2004, MOD) GB/T 11022-2011 high voltage switchgear and control equipment standards common technical requirements (IEC 62271-1:2007, MOD) GB/T 12022 industrial sulfur hexafluoride GB/T 16927.1 high voltage test techniques - Part 1. General definitions and test requirements (GB/T 16927.1-2011, IEC 60060-1:2010, MOD) GB/T 28537 high-voltage switchgear and control equipment in the use and treatment of sulfur hexafluoride (SF6) (GB/T 28537-2012, IEC 62271-303:2008, MOD)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 42 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4208-2017Degrees of protection provided by enclosures (IP code)
- GB/T 7354High-voltage test techniques -- Partial discharge measurements
- GB/T 7354-2003High-voltage test techniques -- Partial discharge measurements
- GB/T 8905The guide for management and measuring SF6 gas in electrical equipment
- GB/T 8905-2012The guide for management and measuring SF6 gas in electrical equipment
- GB/T 11022-2011Common specifications for high-voltage alternating-current switchgear and controlgear standards
GB/T 2421.1 · GB/T 2421.1-2008 · IEC 60068 · GB/T 2900.20-2016 · IEC 60050 · GB/T 2900.83 · GB/T 2900.83-2008 · IEC 60529 · IEC 60270 · IEC 62271 · IEC 60480 · IEC 60060
How to Download GB/T 22383-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12022-2025 — Industrial sulphur hexafluoride
GB/T 16927.1-2011 — High-voltage test techniques -- Part 1: General definitions and test requirements
GB/T 28537-2012 — Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear
Secure payment via Stripe
Payments accepted
GB/T 22383-2017
$605.00