GB/T 20975.17-2020Methods for chemical analysis of aluminium and aluminium alloys—Part 17: Determination of strontium content (English PDF)
铝及铝合金化学分析方法 第17部分:锶含量的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 20975.17-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 29, 2020
Implementation date
August 1, 2021
Scope
GB/T 20975.17-2020 is the English-translated version of 铝及铝合金化学分析方法 第17部分:锶含量的测定.
GB/T 20975.17-2020 is the part of the Chinese series on the chemical analysis of aluminium and aluminium alloys that determines the strontium content. It gives two methods, flame atomic absorption spectrometry for 0.020 % to 12.00 % strontium and Na2EDTA titration for 3.00 % to 22.00 %.
It applies to the arbitration determination of strontium in aluminium and aluminium alloys. Aluminium producers and analytical laboratories use it. Issued on 29 September 2020, it has applied since 1 August 2021, replacing GB/T 20975.17-2008.
Found what you need?
Document preview — GB/T 20975.17-2020
National Standard of the People's Republic of China
- ICS
- 77.120.10
- Classification
- H 12
- Replacing
- GB/T 20975.17-2008
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope6
- 2 Normative references6
- 3 Terms and definitions6
- 4 Flame atomic absorption spectrometry6
- 5 Na2EDTA titration11
- 6 Test report15
1 Scope
This Part of GB/T 20975 specifies the determination of strontium content in aluminum and aluminum alloys by flame atomic absorption spectrometry and Na2EDTA titration.
This Part applies to the arbitration determination of strontium content in aluminum and aluminum alloys. The determination range of flame atomic absorption spectrometry: 0.020 % ~ 12.00 %; the determination range of Na2EDTA titration: 3.00 % ~ 22.00 %.
NOTE: When the strontium mass fraction is > 3.00 % ~ 12.00 %, Na2EDTA titration is used as the arbitration method.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 8005.2 Terms of aluminium and aluminium alloys - Part 2: Chemical analysis
GB/T 8170-2008 Rules of rounding off for numerical values & expression and judgement of limiting values
3 Terms and definitions
For the purpose of this document, the terms and definitions defined in GB/T 8005.2 apply.
4 Flame atomic absorption spectrometry
4.1 Method summary
Dissolve the sample with hydrochloric acid and hydrogen peroxide, measure the absorbance of strontium using air-acetylene rich flame at the wavelength of 460.7 nm of a flame atomic absorption spectrometer, to determine the strontium content.
4.2 Reagents
Unless otherwise stated, only reagents and laboratory grade 2 water confirmed to be of analytical grade are used in the analysis.
4.2.1 Pure aluminum (wAl >= 99.99 %, wSr <= 0.001 %).
4.2.2 Hydrogen peroxide (rho = 1.10 g/mL).
4.2.3 Hydrofluoric acid (rho = 1.14 g/mL).
4.2.4 Nitric acid (rho = 1.42 g/mL).
4.2.5 Hydrochloric acid (1 + 1).
4.2.6 Lanthanum chloride solution (200 g/L): WEIGH 100 g of lanthanum chloride (LaCl3 · 6H2O), DILUTE to a 500 mL volumetric flask with water.
4.2.7 Aluminum solution A (20 mg/mL): WEIGH 20.00 g of pickled pure aluminum (4.2.1) and PLACE it in a 1000 mL beaker, COVER it with a watch glass, and ADD a total of 200 mL of hydrochloric acid (4.2.5) in portions. After the violent reaction stops, ADD a few drops of hydrogen peroxide (4.2.2), HEAT slowly until completely dissolved, and COOL down. TRANSFER the solution into a 1000 mL volumetric flask, DILUTE to the mark with water, and MIX well.
4.2.8 Aluminum solution B (2 mg/mL): PIPETTE 50 mL of aluminum solution (4.2.7) into a 500 mL volumetric flask, DILUTE to the mark with water, and MIX well.
4.2.9 Strontium standard storage solution: WEIGH 1.6850 g of strontium carbonate (wSrCO3 >= 99.99 %) and DISSOLVE it in an appropriate amount of hydrochloric acid (4.2.5), HEAT to boil, COOL down, DILUTE to 1000 mL with water, and MIX well. 1 mL of this solution contains 1.0 mg of strontium.
4.2.10 Strontium standard solution A: PIPETTE 50.00 mL of strontium standard storage solution (4.2.9) into a 200 mL volumetric flask, DILUTE to the mark with water, and MIX well. 1 mL of this solution contains 0.25 mg of strontium.
4.2.11 Strontium standard solution B: PIPETTE 50.00 mL of strontium standard storage solution (4.2.9) into a 500 mL volumetric flask, DILUTE to the mark with water, and MIX well. 1 mL of this solution contains 0.1 mg of strontium.
4.3 Instruments and equipment
Atomic absorption spectrometer with strontium hollow cathode lamp. The instrument shall meet the following conditions:
- Characteristic concentration: in a solution consistent with the matrix of the tested sample solution, the characteristic concentration of strontium shall not be greater than 0.25 µg/mL;
- Precision: use the highest-concentration standard solution to measure the absorbance 10 times, the standard deviation shall not exceed 1.0 % of the average absorbance; use the lowest-concentration standard solution (not a "zero" concentration solution) to measure the absorbance 10 times, the standard deviation shall not exceed 0.5 % of the average absorbance of the highest-concentration standard solution;
- Working curve linearity: divide the working curve into five equal segments according to concentration. The ratio of the absorbance difference of the highest segment to the absorbance difference of the lowest segment shall not be less than 0.7.
4.4 Sample
Process the sample into chips with a thickness of no more than 1 mm.
4.5 Analysis steps
4.5.1 Sample
Weigh the sample (4.4) with a mass (m0) of 0.50 g, accurate to 0.0001 g.
4.5.2 Parallel test
Carry out two tests in parallel and take the average value.
4.5.3 Blank test
Weigh pure aluminum (4.2.1) according to Table 1 to replace the sample (4.5.1), and carry out a blank test along with the sample.
4.5.4 Determination
4.5.4.1 PLACE the sample (4.5.1) into a 250 mL beaker, ADD 15 mL of hydrochloric acid (4.2.5), after the violent reaction stops, ADD 3 ~ 5 drops of hydrogen peroxide (4.2.2), BOIL and STEAM until salt precipitates, COOL down slightly, ADD 3 mL of hydrochloric acid (4.2.5), HEAT until the salts are dissolved, then REMOVE the beaker and COOL down.
4.5.4.2 If there is insoluble matter, filter and wash. PLACE the residue together with the filter paper in a platinum crucible, ASH it (do not burn the filter paper). […]
5 Na2EDTA titration
5.2.3 Ammonia water (rho = 0.89 g/mL).
5.2.4 Hydrochloric acid (1 + 1).
5.2.5 Hexamethylenetetramine solution (250 g/L).
5.2.6 Copper reagent solution (50 g/L): WEIGH 5 g of copper reagent (sodium diethyl aminothiocarbamate) and DISSOLVE it in 25 mL of absolute ethanol (5.2.2), DILUTE to 100 mL with water. (Prepare before use.)
5.2.7 Ammonia-ammonium chloride buffer solution (pH ~ 10): WEIGH 54 g of ammonium chloride and DISSOLVE it in 200 mL of water, ADD 350 mL of ammonia water (5.2.3), and DILUTE to 1000 mL.
5.2.8 Zinc standard solution (c' = 0.02 mol/L): WEIGH 1.3076 g of zinc (wZn >= 99.9 %) and PLACE it in a 300 mL beaker, ADD 20 mL of hydrochloric acid (5.2.4), HEAT to dissolve completely and then EVAPORATE to 10 mL, COOL down, TRANSFER to a 1000 mL volumetric flask, DILUTE to the mark with water, and MIX well.
5.2.9 Magnesium standard solution (0.02 mol/L): WEIGH 0.4861 g of metallic magnesium (wMg >= 99.9 %) and PLACE it in a 300 mL beaker, ADD 30 mL of hydrochloric acid (5.2.4), HEAT to dissolve completely, COOL down, TRANSFER into a 1000 mL volumetric flask, DILUTE to the mark with water, and MIX well.
5.2.10 Na2EDTA standard titration solution (c1 ~ 0.02 mol/L):
- Preparation: WEIGH 7.4 g of disodium ethylenediaminetetraacetate (C10H14N2O8Na2 · 2H2O) and DISSOLVE it in 200 mL of hot water, COOL down, TRANSFER into a 1000 mL volumetric flask with water, and MIX well.
- Calibration: PIPETTE 20.00 mL (V') of zinc standard solution (5.2.8) into a 250 mL Erlenmeyer flask, ADD 50 mL of water and 15 mL of ammonia-ammonium chloride buffer solution (5.2.7), ADD 4 ~ 5 drops of chrome black T indicator (5.2.11), TITRATE the solution with Na2EDTA standard solution (5.2.10) until the solution turns pure blue, which is the end point, and RECORD the volume (V) of the Na2EDTA standard titration solution (5.2.10) consumed. CALIBRATE three copies in parallel, and the difference in volume between the two calibration copies shall not be greater than 0.10 mL.
- Calculation: CALCULATE the concentration of Na2EDTA standard solution according to formula (2):
where:
c' - the concentration of zinc standard solution, in moles per liter (mol/L);
V' - the volume of the zinc standard solution pipetted, in milliliters (mL);
V - the volume of the Na2EDTA standard titration solution consumed, in milliliters (mL).
The calculation results retain four significant figures, and rounding off of numerical values is performed in accordance with 3.2 and 3.3 of GB/T 8170-2008.
5.2.11 Chrome black T indicator: WEIGH 0.2 g of chrome black T and DISSOLVE it in 10 mL of ammonia water (5.2.3) and 40 mL of absolute ethanol (5.2.2). After complete dissolution, store it in a brown dropper bottle. […]
5.3 Sample
Process the sample into chips with a thickness of no more than 1 mm.
5.4 Analysis steps
5.4.1 Sample
Weigh the sample (5.3) with a mass (m) of 0.20 g, accurate to 0.0001 g.
5.4.2 Parallel test
Carry out two tests in parallel and take the average value.
5.4.3 Determination
5.4.3.1 PLACE the sample (5.4.1) into a 250 mL beaker, ADD 6 mL of hydrochloric acid (5.2.4), ADD a few drops of hydrogen peroxide (5.2.1), HEAT, after the sample is completely dissolved, COOL down.
5.4.3.2 DILUTE to about 20 mL with water, NEUTRALIZE with ammonia water (5.2.3) until the pH of the solution is about 6 (precision pH test paper), ADD 15 mL of hexamethylenetetramine solution (5.2.5), CONTROL the pH of the solution to 6. 5 ~ 7.5, HEAT and BOIL for 1 min, then COOL down to room temperature. ADD 10 mL of copper reagent solution (5.2.6) while stirring, TRANSFER it to a 200 mL volumetric flask (V5), DILUTE to the mark with water, and MIX well. LET STAND for 30 min and carry out dry filtration.
5.4.3.3 PIPETTE 50.00 mL of filtrate (V6) into a 250 mL Erlenmeyer flask, ADD water to approximately 100 mL, ADD 10 mL of ammonia-ammonium chloride buffer solution (5.2.7), ADD 10.00 mL (V0) of magnesium standard solution (5.2.9), ADD 3 ~ 5 drops of chrome black T indicator (5.2.11), TITRATE with Na2EDTA standard titration solution (5.2.10) until the color change nears the end point, ADD 7 mL to 8 mL of absolute ethanol (5.2.2), continue to TITRATE until the solution turns pure blue, which is the end point. RECORD the volume of Na2EDTA standard solution consumed (V4). […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
Editions of GB/T 20975.17
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 20975.17-2020 | Methods for chemical analysis of aluminium and aluminium alloys—Part 17: Determination of strontium content | current edition | Current |
| GB/T 20975.17-2008 | Methods for chemical analysis of aluminium and aluminium alloys—Part 17: Determination of strontium content | previous edition | Superseded |
This page sells the current edition, GB/T 20975.17-2020. Earlier editions are listed for reference only.
How to Download GB/T 20975.17-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8005.2-2011 — Terms of aluminium and aluminium alloys -- Part 2: Chemical analysis
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 20975.1-2018 — Methods for chemical analysis of aluminium and aluminium alloys—Part 1: Determination of mercury content
Secure payment via Stripe
Payments accepted
GB/T 20975.17-2020
$150.00