GB/T 20975.15-2020Methods for chemical analysis of aluminium and aluminium alloys—Part 15: Determination of boron content (English PDF)
铝及铝合金化学分析方法 第15部分:硼含量的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 20975.15-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 19, 2020
Implementation date
October 1, 2021
Scope
GB/T 20975.15-2020 is the English-translated version of 铝及铝合金化学分析方法 第15部分:硼含量的测定.
GB/T 20975.15-2020 is the part of the Chinese series on the chemical analysis of aluminium and aluminium alloys that determines the boron content. It gives two ion selective electrode methods: after dissolving the sample in hydrofluoric acid, for 0.0010 % to 5.00 % boron, and after dissolving it in mixed acid, for more than 5.00 % to 11.50 %.
It applies to the arbitration determination of boron in aluminium and aluminium alloys. Aluminium producers and analytical laboratories use it. Issued on 19 November 2020, it has applied since 1 October 2021, replacing GB/T 20975.15-2008.
Found what you need?
Document preview — GB/T 20975.15-2020
National Standard of the People's Republic of China
- ICS
- 77.120.10
- Classification
- H 12
- Replacing
- GB/T 20975.15-2008
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Hydrofluoric acid sample dissolution-ion selective electrode method
Foreword
GB/T 20975 "Methods for Chemical Analysis of Aluminum and Aluminum Alloys" is divided into 37 parts.
---Part 1: Determination of mercury content;
---Part 2: Determination of arsenic content;
---Part 3: Determination of copper content;
---Part 4: Determination of iron content;
---Part 5: Determination of silicon content;
---Part 6: Determination of cadmium content;
---Part 7: Determination of manganese content;
---Part 8: Determination of zinc content;
---Part 9: Determination of lithium content by flame atomic absorption spectrometry;
---Part 10: Determination of tin content;
---Part 11: Determination of lead content;
---Part 12: Determination of titanium content;
---Part 13: Determination of vanadium content;
---Part 14: Determination of nickel content;
---Part 15: Determination of boron content;
---Part 16: Determination of magnesium content;
---Part 17: Determination of strontium content;
---Part 18: Determination of Chromium Content;
---Part 19: Determination of Zirconium Content;
---Part 20: Determination of Gallium Content Butyl Rhodamine B Spectrophotometry;
---Part 21: Determination of calcium content;
---Part 22: Determination of beryllium content;
---Part 23: Determination of antimony content;
---Part 24: Determination of total rare earth content;
---Part 25: Determination of element content by inductively coupled plasma atomic emission spectrometry;
---Part 26: Determination of carbon content by infrared absorption method;
---Part 27: Determination of cerium, lanthanum and scandium content by inductively coupled plasma atomic emission spectrometry;
---Part 28: Determination of cobalt content by flame atomic absorption spectrometry;
---Part 29: Determination of molybdenum content thiocyanate spectrophotometric method;
---Part 30: Determination of hydrogen content by heating extraction thermal conductivity method;
---Part 31: Determination of phosphorus content molybdenum blue spectrophotometry;
---Part 32: Determination of Bismuth Content;
---Part 33: Determination of potassium content by flame atomic absorption spectrometry;
---Part 34: Determination of sodium content by flame atomic absorption spectrometry;
---Part 35: Determination of Tungsten Content Thiocyanate Spectrophotometric Method;
---Part 36: Determination of silver content by flame atomic absorption spectrometry;
--- Part 37: Determination of Niobium Content.
This part is Part 15 of GB/T 20975.
This section was drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB/T 20975.15-2008 "Methods for Chemical Analysis of Aluminum and Aluminum Alloy Part 15: Determination of Boron Content". versus Compared with GB/T 20975.15-2008, in addition to editorial changes, the main technical changes are as follows.
---Added standard use safety warning;
--- Added "Normative Reference Documents" (see Chapter 2);
--- Added "Terms and Definitions" (see Chapter 3);
--- Modified "Ion Selective Electrode Method" to "Hydrofluoric Acid Dissolving Sample-Ion Selective Electrode Method" (see Chapter 4, Method 1 of the 2008 edition Ion selective electrode method);
--- Delete "carmine spectrophotometry" (see the 2008 edition of the method two carmine spectrophotometry);
---Modified the precision of the hydrofluoric acid sample-ion selective electrode method (see 4.7, Chapter 8 of the 2008 edition);
--- Added "Mixed Acid Dissolution Sample-Ion Selective Electrode Method" (see Chapter 5);
--- Added "Test Report" (see Chapter 6).
1 Scope
This part of GB/T 20975 specifies the hydrofluoric acid sample-ion selective electrode method and the mixed acid sample-ion selective electrode method for the determination of aluminum And the boron content in aluminum alloy.
This section applies to the arbitration determination of boron content in aluminum and aluminum alloys. Hydrofluoric acid sample-ion selective electrode method, measurement range. 0.0010%~ 5.00%; mixed acid solution sample-ion selective electrode method determination range. >5.00%~11.50%.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.
GB/T 8005.2 Terminology of Aluminum and Aluminum Alloy Part 2: Chemical Analysis
GB/T 8170-2008 Numerical rounding rules and the expression and determination of limit values
3 Terms and definitions
The terms and definitions defined in GB/T 8005.2 apply to this document.
4 Hydrofluoric acid sample dissolution-ion selective electrode method
4.1 Method summary
The sample is dissolved with hydrofluoric acid and hydrogen peroxide, boron is converted into fluoroborate ions, and the pH of the test solution is adjusted to 5-6 with sodium hydroxide solution.
Fluoroborate ion-selective electrode measures the potential value of fluoroborate ion to determine the boron content. The sum of copper mass fraction and iron mass fraction When it is greater than 10%, it interferes with the determination and is eliminated by complexation with disodium ethylenediaminetetraacetic acid.
4.2 Reagents
Unless otherwise stated, only reagents and laboratory secondary water confirmed to be analytically pure are used in the analysis.
4.2.1 Pure aluminum (wAl>=99.99%, wB<=0.0005%).
4.2.2 Hydrofluoric acid (rho=1.14g/mL).
4.2.3 Hydrogen peroxide (rho=1.10g/mL).
4.2.4 Disodium ethylenediaminetetraacetic acid (Na2EDTA) solution (100g/L).
4.2.5 Sodium hydroxide solution (200g/L), stored in a polyethylene bottle.
4.2.6 Boron standard solution A. Weigh 0.5720g of boric acid (excellent grade pure) that has been dried in a vacuum dryer in a 400mL beaker, add Pour.200mL of water and heat it to completely dissolve it. After cooling, transfer to a 500mL volumetric flask, dilute to the mark with water, and mix well. Stored in polyethylene […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
Editions of GB/T 20975.15
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 20975.15-2020 | Methods for chemical analysis of aluminium and aluminium alloys—Part 15: Determination of boron content | current edition | Current |
| GB/T 20975.15-2008 | Methods for chemical analysis of aluminium and aluminium alloys—Part 15: Determination of boron content | previous edition | Superseded |
This page sells the current edition, GB/T 20975.15-2020. Earlier editions are listed for reference only.
How to Download GB/T 20975.15-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8005.2-2011 — Terms of aluminium and aluminium alloys -- Part 2: Chemical analysis
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 20975.16-2020 — Methods for chemical analysis of aluminium and aluminium alloys—Part 16: Determination of magnesium content
Secure payment via Stripe
Payments accepted
GB/T 20975.15-2020