GB/T 19212.27-2017Safety of transformers, reactors, power supply units and combinations thereof -- Part 27: Particular requirements and tests for transformers and power supply units all for saving energy and other purposes (English PDF)
变压器、电抗器、电源装置及其组合的安全 第27部分:节能和其他目的用变压器和电源装置的特殊要求和试验
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19212.27-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
December 29, 2017
Implementation date
July 1, 2018
Scope
GB/T 19212.27-2017 is the English-translated version of 变压器、电抗器、电源装置及其组合的安全 第27部分:节能和其他目的用变压器和电源装置的特殊要求和试验.
GB/T 19212.27-2017 — This clause GB/T 19212.1-2016 is replaced by the following.
This section GB/T 19212 specifies the safety requirements for energy-saving and other purposes with transformers, power supply units and switching power supply units, in electrical installations, energy savings and other purposes are achieved by adjusting the output voltage and/or other electrical characteristics of the output circuit, free from transformers, Power supply and switching power supply unit interrupts.
Note 1. Safety requirements include electrical, temperature and mechanical aspects. Energy saving is achieved through voltage stabilization and/or voltage regulation of the electrical installation.
This standard can also be used to adjust the voltage or scheduled the final adjustment of other electrical characteristics of the power supply and switching power supply unit.
Note 2. Lighting for outdoor or indoor use is an example of an electrical installation. Note 3. The reduction of output voltage in some special applications may affect the safety and performance of power supply equipment.
This section applies to single-phase or three-phase, air-cooled (self-cooled or air-cooled), independently or with the following GB/T 19212 series of standards Energy-saving transformers, power supply units and switching power supply units for the provision of transformers and/or power supply units. --- Part 2.
Particular requirements and tests for power supply units for general purposes separation transformers and built-in separation transformers; --- Part 5. Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers; --- Part 7.
Particular requirements and tests for power supply units for safety-isolated transformers and built-in safety isolating transformers; --- Part 14. Particular requirements and tests for autotransformers and power supply units incorporating autotransformers; --- Part 15.
Particular requirements and tests for the power supply of voltage regulators and built-in voltage regulators; --- Part 17. Particular requirements and tests for transformers for switching power supply units and switching power supply units.
Rated supply voltage does not exceed AC 1000V, rated power frequency does not exceed 500Hz. This section applies to the internal frequency does not exceed 500Hz linear power supply unit.
This section GB/T 19212.17 combined with the use, but also for internal work frequency of more than 500Hz energy-saving switching power supply unit Set and transformer.
GB/T 19212 series for the other part of the corresponding specific application, in addition to the requirements listed in this section, the corresponding necessary requirements be applicable.
When the two requirements conflict, priority is given to the most stringent requirements. Rated output does not exceed. --- 150kVA, for single-phase energy-saving transformers, power supply and switching power supply unit; --- 400kVA, for three-phase energy-saving transformers, power supply and switching power supply unit.
This section also applies to energy-saving transformers, power supply units, and power supply units not limited to the rated output if purchaser and manufacturer have otherwise agreed Switching power supply unit.
This section does not apply to be scheduled to be connected to the energy-saving transformer, power supply and switching power supply input terminals and/or output External circuit of the terminal and its components.
This section does not apply to other devices with similar functions, such as dual-level control devices, electronic control devices and other standard packages Special lighting regulator included.
Protection against external influences such as molds, pests, termites, solar radiation and icing on components in the enclosure and enclosure should also be avoided
Found what you need?
Document preview — GB/T 19212.27-2017
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements
- 5 General description of the test
- 6 Rating
- 7 Categories
- 8 Signs and other information
- 9 Shock protection
- 10 Change of input voltage setting
- 11 Load output voltage and output current
- 12 No-load output voltage
- Short circuit voltage
- 14 Fever
- Short circuit and overload protection
- 16 Mechanical strength
- 17 To prevent dust, solid foreign bodies and damp harmful entry
Foreword
GB/T 19212 "Transformers, Reactors, Power Supplies and Their Combination Safety" 1) consists of the following parts.
1) Some of the standards in this series are under the heading "Safety of Power Transformers, Power Supplies, Reactors and Similar Products" and some are under the heading "Supply Voltage Under the heading "Safety of transformers, reactors, power supply units and similar products up to and including 1100V" under the heading "Transformers, Reactors, Power Source device and its combination of security "heading, the title of the series of standards released in the future may be modified.
--- Part 1. General requirements and tests;
--- Part 2. Particular requirements and tests for the power supply for general purposes separation transformers and built-in separation transformers;
--- Part 3. Particular requirements and tests for controlling the power supply of transformers and control transformers built in;
--- Part 4. Gas and oil burners ignition transformers special requirements and tests;
--- Part 5. Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers;
--- Part 6. Particular requirements and tests for razor transformers, shaver power supply units and razor power supply units;
--- Part 7. Particular requirements and tests for power supply units for safety-isolated transformers and built-in safety isolating transformers;
--- Part 8. Particular requirements and tests for transformers and power supplies for toys;
--- Part 9. Bell and electric bell transformers and power supply special requirements and tests;
--- Part 10. Particular requirements and tests for transformers and power supply units for class III portable tungsten lamps;
--- Part 13. Constant voltage transformer special requirements;
--- Part 14. Particular requirements and tests for autotransformers and power supply units incorporating autotransformers;
--- Part 15. Particular requirements and tests for the power supply of voltage regulators and built-in voltage regulators;
--- Part 16. Particular requirements and tests for isolation transformers for power supply in medical premises;
--- Part 17. Particular requirements and tests for transformers for switching power supply units and switching power supply units;
--- Part 20. Interference attenuation transformer special requirements;
--- Part 21. Particular requirements and tests for small reactors;
--- Part 24. Particular requirements for transformers used in construction sites;
--- Part 27. Particular requirements and tests for energy-saving and other purposes for transformers and power supply units.
This section GB/T 19212 Part 27. This section is based on the GB/T 19212.1-2016 developed on the basis of this section Need to be used with GB/T 19212.1-2016. This section is GB/T 19212.1-2016 the corresponding chapter, Article supplement and repair Change in order to GB/T 19212.1-2016 content into the contents of this section. This section is for GB/T 19212.1-2016 added the added content starts from 101.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the redrafted law to amend the use of IEC 61558-2-26:2013 "transformers, reactors, power supply units and combinations of safety Part 2-26. Particular requirements and tests for transformers and power supply units for energy conservation and other purposes ".
This section compared with IEC 61558-2-26:2013 there are technical differences, all of these differences are due to the standard part of this standard GB/T 19212.1-2016 and IEC 61558-1:2009 in Chapter 2 arising from the technical differences arising.
This part is proposed by China Electrical Equipment Industry Association.
This part of the national small-scale power transformers, reactors, power devices and similar products Standardization Technical Committee (SAC/TC418) Focused.
This part of the drafting unit. Shenyang Transformer Research Institute Co., Ltd., Shanghai Institute of Quality Supervision, Inspection and Technical Supervision, the State Radio and Television as Product Quality Supervision and Inspection Center, Ministry of Industry and Information Technology Institute of the Fifth Institute of Quality and Safety Testing Center , Shanghai Exit Inspection and Quarantine Epidemic mechanical and electrical products testing technology center.
1 Scope
This clause GB/T 19212.1-2016 is replaced by the following.
This section GB/T 19212 specifies the safety requirements for energy-saving and other purposes with transformers, power supply units and switching power supply units, in electrical installations, energy savings and other purposes are achieved by adjusting the output voltage and/or other electrical characteristics of the output circuit, free from transformers, Power supply and switching power supply unit interrupts.
Note 1. Safety requirements include electrical, temperature and mechanical aspects.
Energy saving is achieved through voltage stabilization and/or voltage regulation of the electrical installation. This standard can also be used to adjust the voltage or scheduled the final adjustment of other electrical characteristics of the power supply and switching power supply unit.
Note 2. Lighting for outdoor or indoor use is an example of an electrical installation.
Note 3. The reduction of output voltage in some special applications may affect the safety and performance of power supply equipment.
This section applies to single-phase or three-phase, air-cooled (self-cooled or air-cooled), independently or with the following GB/T 19212 series of standards Energy-saving transformers, power supply units and switching power supply units for the provision of transformers and/or power supply units.
--- Part 2. Particular requirements and tests for power supply units for general purposes separation transformers and built-in separation transformers;
--- Part 5. Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers;
--- Part 7. Particular requirements and tests for power supply units for safety-isolated transformers and built-in safety isolating transformers;
--- Part 14. Particular requirements and tests for autotransformers and power supply units incorporating autotransformers;
--- Part 15. Particular requirements and tests for the power supply of voltage regulators and built-in voltage regulators;
--- Part 17. Particular requirements and tests for transformers for switching power supply units and switching power supply units.
Rated supply voltage does not exceed AC 1000V, rated power frequency does not exceed 500Hz.
This section applies to the internal frequency does not exceed 500Hz linear power supply unit.
This section GB/T 19212.17 combined with the use, but also for internal work frequency of more than 500Hz energy-saving switching power supply unit Set and transformer.
GB/T 19212 series for the other part of the corresponding specific application, in addition to the requirements listed in this section, the corresponding necessary requirements be applicable.
When the two requirements conflict, priority is given to the most stringent requirements.
Rated output does not exceed.
--- 150kVA, for single-phase energy-saving transformers, power supply and switching power supply unit;
--- 400kVA, for three-phase energy-saving transformers, power supply and switching power supply unit.
This section also applies to energy-saving transformers, power supply units, and power supply units not limited to the rated output if purchaser and manufacturer have otherwise agreed Switching power supply unit.
This section does not apply to be scheduled to be connected to the energy-saving transformer, power supply and switching power supply input terminals and/or output External circuit of the terminal and its components.
This section does not apply to other devices with similar functions, such as dual-level control devices, electronic control devices and other standard packages Special lighting regulator included.
Protection against external influences such as molds, pests, termites, solar radiation and icing on components in the enclosure and enclosure should also be avoided
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
How to Download GB/T 19212.27-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19212.1-2023 — Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
GB/T 19212.11-2020 — Safety of transformers, reactors, power supply units and combinations thereof - Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V
GB/T 19212.13-2019 — Safety of transformers, reactors, power supply units and combination thereof -- Part 13: Particular requirements and tests for constant voltage transformers and power supply units for constant voltage
Secure payment via Stripe
Payments accepted
GB/T 19212.27-2017
$295.00