GB/T 19212.20-2008Safety of power transformers, power supply units and similar -- Part 20: Particular requirements for perturbation attenuation transformers (English PDF)
This is a limited preview
Buy now to download the full PDF (8 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19212.20-2008 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
March 24, 2008
Implementation date
January 1, 2009
Scope
GB/T 19212.20-2008 (Safety of power transformers, power supply units and similar -- Part 20: Particular requirements for perturbation attenuation transformers) is available as an English-translated PDF.
GB/T 19212.20-2008 — The chapter GB 19212.1-2003 by the following instead. This section provides various aspects of the transformer (eg, electrical, thermal and mechanical aspects) safety requirements.
This section applies to Stationary or mobile, single-phase or multi-phase, air-cooled (natural cooling or forced cooling), alone or supporting the use of isolation or safety isolating transformer, its rated supply voltage not exceeding AC 1000V, rated frequency not exceeding 500Hz, rated output not exceeding 10kVA.
Disturbance attenuation transformer intended to be used as office equipment or similar equipment power supply, the output circuit having a midpoint output to it attenuate conducted interference MAINS.
In addition, the installation procedures and equipment specifications double insulation or reinforced insulation between circuits should be implemented through the use of such a transformer.
Note 1. The use of such a transformer connected to the device specified in this does not mean that you can reduce the requirements for the device.
Disturbance attenuation isolating transformer. --- No-load output voltage and rated output voltage exceeding 50V AC or ripple-free DC 120V, but not more than AC 500V or Ripple-free DC 708V; To comply with national wiring regulations or requirements for a particular purpose, no-load output voltage or the rated output voltage these limits may be exceeded, but not exceed 1000V AC or ripple-free DC 1415V.
Disturbance attenuation safety isolating transformer. --- No-load output voltage or the rated output voltage does not exceed 50V AC or ripple-free DC 120V. This section applies to dry-type transformers.
Windings can be sealed or non-sealed. If the isolation transformer to two or more devices to provide power, so some of the devices connected to the exposed conductive parts Need to comply with the provisions of 413.5 of IEC 60364-4-41.
Note 2. The media is filled with a liquid or powder material (such as sand) of the transformer, the additional requirements are under consideration.
Note 3. to note the following. --- For transformer intended to use in a tropical climate countries, special requirements may be necessary; --- Located in areas of special environmental conditions may require specific requirements.
Note 4. This section does not prevent the use of the output circuit midpoint no other types of transformers as attenuation transformers. This section does not include the performance of "decay" feature.
This function can be different characteristics, e.g., to block or special laminate obtain. This section also applies to transformers incorporating electronic circuits.
This part is not intended to be used with the transformer input and output terminals or output A receptacle connector and an external circuit components.
Found what you need?
Document preview — GB/T 19212.20-2008
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- What this standard covers1
- Document data2
- Standards quoted by this document3
What this standard covers
This Chinese standard specifies the safety requirements for all aspects of the transformer. This standard applies to stationary or mobile, single -phase or polyphase, air-cooled, independence or supporting the use of isolation or safety isolation transformers, power supply voltage does not exceed the rated AC 1000V, rated frequency not exceeding 500Hz, rated output not exceeding 10kVA. Interference attenuation transformers intended to be used as office equipment or similar equipment supply, with a midpoint in the output circuit output to attenuate conducted interference power grid. In addition, the installation procedures and equipment specifications circuit between the double insulation or reinforced insulation should be achieved through the use of this transformer. This standard applies to dry-type transformers. Its winding can be sealed or non- sealed. If the isolation transformer to two or more devices to provide power, then some of the equipment so exposed conductive parts of the connection need to meet IEC 60364-4-41 requirements of 413. 5. This standard does not include"decay"function of the performance. This feature can be of different characteristics, such as to obtain a laminated block or special. This is also applicable to an electronic circuit with a transformer. This standard is not intended to be used with the transformer input and output terminals or output jack to connect an external circuit and its components.
Document data
International classification (ICS): 29.180.
Chinese classification (CCS): K41.
Estimated length of the Chinese original: 12,121 words.
Adopted international standard: IEC 61558-2-19-2000, MOD.
Standards quoted by this document
GB 19212.1-2003
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.
Referenced standards
Normative references
GB 19212.1-2003
How to Download GB/T 19212.20-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19212.1-2023 — Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
GB/T 19212.11-2020 — Safety of transformers, reactors, power supply units and combinations thereof - Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V
GB/T 19212.13-2019 — Safety of transformers, reactors, power supply units and combination thereof -- Part 13: Particular requirements and tests for constant voltage transformers and power supply units for constant voltage
Secure payment via Stripe
Payments accepted
GB/T 19212.20-2008
$150.00