GB/T 19185-2008Calculation method of live working minimum approach distance on a.c.transmission line (English PDF)

交流线路带电作业安全距离计算方法

Open the GB/T 19185-2008 preview as PDF

Preview — first pages of GB/T 19185-2008 (full document: 9 pages)

This is a limited preview

Buy now to download the full PDF (9 pages)

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Recommended

Issue date

September 24, 2008

Implementation date

August 1, 2009

Scope

GB/T 19185-2008 is the English-translated version of 交流线路带电作业安全距离计算方法.

GB/T 19185-2008 is the Chinese national standard on calculation method of live working minimum approach distance on a.c.transmission line, in the field of electrical engineering. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 24 September 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 August 2009. Classification: ICS 29.240.20, CCS K47. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB/T 19185-2008

National Standard of the People's Republic of China

ICS
29.240.20
Classification
K47

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope1
  • 2 Normative references1
  • 3 Terms and definitions 4 lines operating over-voltage 25
  • 4 Environmental impact of 85
  • 9 Calculation Example5

Foreword

This standard replaces GB/T 19185-2003 "AC Live Line Work Safety Distance Calculation Method." The main difference compared with the standard GB/T 19185-2003 as follows:

--- On the "Terms and Definitions" chapter "occupying an intermediate potential conductor length", "a combination of a minimum clearance", "statistical safety factor", "middle Conductor potential influence coefficients "and other terms were added;

--- In the "Calculation Method" chapter complements the "minimum clearance combination" is calculated;

--- In the "coefficient calculation and values" chapter complements the "occupying intermediate potential conductor length", "middle conductor potential impact factor" of Value method;

--- On the "Calculation examples" chapter "Table 3 security clearance from the combination calculated value" added "a combination of minimum clearance" list. The standard proposed by China Electricity Council. This standard by the National Standardization Technical Committee work and live under the jurisdiction responsible for the interpretation. This standard was drafted. State Grid Wuhan High Voltage Research Institute, Henan Province Pingdingshan Electric Power Bureau. The main drafters of this standard. Hu Yi, Zhao Jiang, Wu Weining, Yi Hui, Zhang Lihua, Hujian Xun, Shu, the peak. This standard replaces the standards previously issued as follows:

--- GB/T 19185-2003. AC Live Line Work Safety Distance Calculation

1 Scope

GB/T 19185-2008 is the Chinese national standard on calculation method of live working minimum approach distance on a.c.transmission line, in the field of electrical engineering. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 24 September 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 August 2009. Classification: ICS 29.240.20, CCS K47. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

This standard specifies the calculation method of the exchange of live line work and combination safe distance gap, risk assessment criterion, the gap coefficient, sea Stubbs correction coefficient. The result of the calculation for the design and testing research reference. This standard applies to 110kV ~ 750kV AC live line work safe distance and gap combination calculating and checking. In the substation located Combination safe distance and prepare for live working gap calculation check, but also can refer to use.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 18037 live working tools Technical requirements and design guide Overvoltage protection and insulation coordination DL/T 620 AC electrical installations

3 Terms and Definitions

The following terms and definitions apply to this standard.

3.1 RMS maximum operating voltage under normal operating conditions, the system appears (phase - phase). 3.2 2% probability of occurrence of overvoltage.

3.3 Insulation presents a 50% probability of flashover impulse voltage peaks.

3.4 Insulating render 90% probability withstand impulse voltage peaks.

3.5 To ensure that the job presents minimal clearance gap 90% probability impulse withstand distance.

3.6 The projected length of the body is part of the job gap on the gap axis.

3.7 Clearance operation minimum allowed value of the distance from the minimum safe distance from electrical body composition range of activities.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 19185

EditionTitleRevisionStatus
GB/T 19185-2008Calculation method of live working minimum approach distance on a.c.transmission linecurrent editionCurrent
GB/T 19185-2003Live working-Miniumu approach distanced-method of calculationprevious editionSuperseded

This page sells the current edition, GB/T 19185-2008. Earlier editions are listed for reference only.

How to Buy GB/T 19185-2008

  1. 1Add to cart. Click the "Buy GB/T 19185-2008" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 19185-2008

$140.00

$120.00for partners