GB/T 18233.5-2018Information technology -- Generic cabling for customer premises -- Part 5: Data centres (English PDF)
Also coversGBT18233.5-2018
Open the GB/T 18233.5-2018 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
December 28, 2018
Implementation date
December 28, 2018
Scope
GB/T 18233.5-2018 (Information technology -- Generic cabling for customer premises -- Part 5: Data centres) is available as an English-translated PDF.
GB/T 18233.5-2018 — This part of GB/T 18233 specifies general cabling for equipment rooms and access rooms in data center buildings, or other types of buildings. General cabling for in-data centers, including balanced cabling and fiber optic cabling. This section is mainly applicable to buildings with a maximum telecommunications service distance of.2000m. Systems with larger distances can be used as reference. The cabling system specified in this section supports a wide range of applications, including audio, data and video, as well as power. This section is directly or by reference to ISO /IEC 11801-1.2017. a) the structure and minimum configuration of the general cabling in the data center; b) equipment outlet (EO) interface and external network interface (ENI); c) performance requirements for cabling links and channels; d) requirements and options for implementation; e) performance requirements for cabling components; f) Compliance requirements and verification procedures. Safety (electrical safety and protection, fire protection, etc.) and electromagnetic compatibility (EMC) requirements are regulated by other standards and regulations and are not included in this section. In the range. However, the information given in this section helps to comply with these standards and specifications.
Document preview — GB/T 18233.5-2018
National Standard of the People's Republic of China
- ICS
- 35.200
- Classification
- L 65
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
Foreword
GB/T 18233 "General cable for information technology users' buildings" is divided into the following parts.
--- Part 1. General requirements;
--- Part 2. Office space;
--- Part 3. Industrial buildings;
--- Part 4. Residential;
--- Part 5. Data Center;
--- Part 6. Distributed building facilities.
This part is the fifth part of GB/T 18233.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section uses the translation method equivalent to ISO /IEC 11801-5..2017 "Information Technology User Buildings General Cables Part 5
Points. Data Center.
This standard incorporates the contents of ISO /IEC 11801-5.2017/COR1.2018 and is used in the margins of the outer side of its corresponding clause.
The vertical double line (||) is marked.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
--- GB/T 34961.2-2017 Information technology user building group cabling implementation and operation Part 2. Planning and installation
(ISO /IEC 14763-2.2012, IDT)
Introduction
Cable installations are as important as other infrastructures such as water supply and energy supply, and disruption of cabling system services can also have serious implications. by
Poor service due to lack of planning, improper use of components, improper installation, poor management, or inadequate support may be given to users.
Bring business losses.
This part of GB/T 18233 describes general cabling in data center equipment rooms and access data centers, or other types of buildings.
General cabling within the data center.
In addition, it also includes.
---The cabling of the office space specified in ISO /IEC 11801-2;
--- Cables for industrial sites as specified in ISO /IEC 11801-3.
ISO /IEC 11801-6 specifies cabling for distributed building facilities and also covers all of the above locations and conditions.
Figure 1 shows the relationship between the standards for cabling and information technology reports developed by ISO /IEC JTC1/SC25. which is
Standards for cabling design, installation, operation, and management in ISO /IEC 11801, and test standards for installed cabling.
Figure 1 Relationship between common cabling standards established by ISO /IEC JTC1/SC25
The general cabling specified in this section will provide the following services to users.
a) provide users with a separate cabling system that supports a wide range of applications within the installation and operating environment;
b) Provide users with flexible cabling solutions that make the modifications simple and economical;
c) supply chain of multi-provider cabling components in an open market environment;
In addition to this, this section provides.
d) provide guidance to industry professionals to allow installation of cabling prior to obtaining specific requirements, such as initial plans for construction or renovation,
And when determining future deployment requirements.
e) Provide guidance to the cabling system industry and standards organizations supporting existing products as standardization for future product development and application
basis.
The applications covered in this section include sub-technical committees under the IEC (including sub-technical committees under ISO /IEC JTC1) and
Developed by ITU-T's research group to support high data rate, mission-critical services in a data center space-intensive connection environment.
This section takes into account the application requirements listed in ISO /IEC 11801-1.2017 Appendix E.
This part should be used in conjunction with ISO /IEC 11801-1.2017. The general requirements for general cabling are specified in ISO /IEC 11801-1.2017.
Make the other standards in the ISO /IEC 11801 series have general requirements that can be referenced.
The physical layer requirements for the applications listed in Appendix E of ISO /IEC 11801-1.2017 have been determined to be compatible with the cabling performance specified in this section.
With the statistics of the premises in different countries and the model described in Chapter 6, the requirements for the cabling components are specified and they are specified in the cabling system.
Arrangement.
Therefore, this section describes the cabling structures that support a wide range of applications.
1) Adopt balanced cabling channels and EA, F, FA, I and II links as specified in ISO /IEC 11801-1.2017;
2) Adopt the component requirements specified in ISO /IEC 11801-1.2017 to ensure the performance of a cable for permanent links and channels
Or more than a specific application (eg, level);
3) Adopt the fiber optic cabling channel and link requirements specified in ISO /IEC 11801-1.2017.
The expected life of a typical cabling system depends on environmental conditions, supported applications, the life of the materials used in the cable, and other such as path connections.
Factors such as (the campus path is more difficult to access than the building path). Select the appropriate components and meet the expected life expectancy of the cabling system at least in accordance with this section.
For 10 years.
This section takes into account the application requirements listed in ISO /IEC 11801-1.2017 Appendix E, and also refers to the relevant components and testers.
The relevant standards of the law.
Information technology user building group general cable
Part 5. Data Center
1 Scope
This part of GB/T 18233 specifies general cabling for equipment rooms and access rooms in data center buildings, or other types of buildings.
General cabling for in-data centers, including balanced cabling and fiber optic cabling.
This section is mainly applicable to buildings with a maximum telecommunications service distance of.2000m. Systems with larger distances can be used as reference.
The cabling system specified in this section supports a wide range of applications, including audio, data and video, as well as power.
This section is directly or by reference to ISO /IEC 11801-1.2017.
a) the structure and minimum configuration of the general cabling in the data center;
b) equipment outlet (EO) interface and external network interface (ENI);
c) performance requirements for cabling links and channels;
d) requirements and options for implementation;
e) performance requirements for cabling components;
f) Compliance requirements and verification procedures.
Safety (electrical safety and protection, fire protection, etc.) and electromagnetic compatibility (EMC) requirements are regulated by other standards and regulations and are not included in this section.
In the range. However, the information given in this section helps to comply with these standards and specifications.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
ISO /IEC 11801-1.2017 General cable for information technology users - Part 1. General requirements
technology-Genericcablingforcustomerpremises-Part 1.Generalrequirements)
ISO /IEC 14763-2 Implementation and operation of information technology user building cabling - Part 2. Planning and installation
(Informationtechnology-Implementationandoperationofcustomerpremisescabling-Part 2.Plan-
Ningandinstalation)
ISO /IEC 30129 Telecommunications connection network for information technology buildings and other building structures (Informationtechnology-
Telecommunicationsbondingnetworksforbuildingsandotherstructures)
IEC 60603-7-7 Connectors for electronic equipment - Part 7-7. 8-channel active for data transmission up to 600 MHz
And detailed specifications for fixed shielded connectors (Connectorsforelectronicequipment-Part 7-7.Detailspecification
For8-way,shielded,freeandfixedconnectors,fordatatransmissionswithfrequenciesupto600MHz)
IEC 60603-7-41 Connectors for electronic equipment - Part 7-41. 8-channel activity for data transmission up to 500 MHz
Detailed specification for fixed and fixed unshielded connectors (Connectorsforelectronicequipment-Part 7-41. Detailspecifi-
Cationfor8-way, unshielded, freeandfixedconnectors, fordatatransmissionswithfrequenciesupto
500MHz)
IEC 60603-7-51 Connectors for electronic equipment - Part 7-51. 8-channel activity for data transmission up to 500 MHz
Detailed specification for fixed and fixed shielded connectors (Connectorsforelectronicequipment-Part 7-51.Detail
Specificationfor8-way,shielded,freeandfixedconnectors,fordatatransmissionswithfrequenciesup
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
IEC 11801 · IEC 14763 · IEC 30129 · IEC 60603
How to Buy GB/T 18233.5-2018
- 1Add to cart. Click the "Buy GB/T 18233.5-2018" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18233.1-2022 — Information technology - Generic cabling for customer premises - Part 1: General requirements
GB/T 18233.2-2022 — Information technology - Generic cabling for customer premises - Part 2: Office premises
GB/T 18233.3-2018 — Information technology -- Generic cabling for customer premises -- Part 3: Industrial premises
Secure payment via Stripe
Payments accepted
GB/T 18233.5-2018
$620.00