GB/T 17680.12-2025Criteria for emergency preparedness and response for nuclear power plants - Part 12: Planning, preparation, conduct and evaluation of nuclear emergency exercises (English PDF)
核电厂应急准备与响应准则 第12部分:核应急演习的策划、准备、实施与评估
Open the GB/T 17680.12-2025 preview as PDF
This is a limited preview
Buy now to download the full PDF (22 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 5, 2025
Implementation date
October 5, 2025
Scope
GB/T 17680.12-2025 is the English-translated version of 核电厂应急准备与响应准则 第12部分:核应急演习的策划、准备、实施与评估.
GB/T 17680.12-2025 is the Chinese national standard covering the nuclear emergency exercise - the objectives and the scenario built to test them, the controllers and evaluators, the conduct on the day, and the evaluation and corrective actions, which is the only part that changes anything. Part 12 of the series. It replaces GB/T 17680.12-2008 and is already in force. It was issued on 5 October 2025 and has been in force since 5 October 2025, replacing GB/T 17680.12-2008. The document is under the responsibility of the Standardization Administration of China. This page is published from the official record of the 2025 edition; the clause text of a standard this recent is not yet in circulation, and the figures, limits and tables it contains are those of the document itself, delivered in full with the English translation.
Document preview — GB/T 17680.12-2025
National Standard of the People's Republic of China
- ICS
- 27.120
- Classification
- F 77
- Replacing
- GB/T 17680.12-2008
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1.Scope1
- 2 Normative References1
- 3.Terms and Definitions1
- 4.Planning2
- 6.Implementation of11
- 16 Reference18
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part
1.Structure and Drafting Rules of Standardization Documents". Drafting. This document is Part 12 of GB/T 17680.GB/T 17680 has the following parts published.
---Nuclear Power Plant Emergency Planning and Preparedness Guidelines Part
1.Delineation of Emergency Planning Zones;
---Nuclear Power Plant Emergency Preparedness and Response Guidelines Part
2.Off-site Emergency Organization and Functions;
---Nuclear Power Plant Emergency Preparedness and Response Guidelines Part
3.Functions and Characteristics of Off-site Emergency Facilities;
---Nuclear Power Plant Emergency Preparedness and Response Guidelines, Part
4.Off-site Nuclear Emergency Plans and Implementation Procedures;
---Nuclear Power Plant Emergency Planning and Preparedness Guidelines Part
5.Maintaining Off-Site Emergency Response Capabilities;
---Nuclear Power Plant Emergency Preparedness and Response Guidelines, Part
6.On-site Emergency Organization and Functions;
1 Scope
GB/T 17680.12-2025 is the Chinese national standard covering the nuclear emergency exercise - the objectives and the scenario built to test them, the controllers and evaluators, the conduct on the day, and the evaluation and corrective actions, which is the only part that changes anything. Part 12 of the series. It replaces GB/T 17680.12-2008 and is already in force. It was issued on 5 October 2025 and has been in force since 5 October 2025, replacing GB/T 17680.12-2008. The document is under the responsibility of the Standardization Administration of China. This page is published from the official record of the 2025 edition; the clause text of a standard this recent is not yet in circulation, and the figures, limits and tables it contains are those of the document itself, delivered in full with the English translation.
This document sets forth the guidelines for the planning, preparation, implementation, and evaluation of nuclear power plant nuclear accident emergency drills (hereinafter referred to as "drills"). This document applies to drills conducted by the nuclear emergency response organization (hereinafter referred to as "on-site emergency response organization") of nuclear power plant operators. Other nuclear facilities may refer to this document. implement.
2 Normative references
This document has no normative references.
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Emergency exercise This was conducted to test the effectiveness of the emergency plan, the comprehensiveness of emergency preparedness, the adaptability of emergency response capabilities, and the coordination of emergency personnel. This is a practice activity that simulates emergency response.
3.2 Accident scenario The description of the events or accidents simulated in the exercise includes the sequence of events (accidents), state characteristics, and the evolution process over time.
3.3 Exercise scenario To organize and implement nuclear emergency drills and achieve the expected objectives, based on accident scenarios, the sequence of events (accidents) and their timing are analyzed. The process should be appropriately trimmed, compressed, or expanded, and the characteristics and process of the event (accident) should be described in detail, along with the corresponding response actions.
3.4 Players Personnel who assume designated emergency response roles within an emergency organization during the exercise.
3.5 controllers Personnel who supervise and guide the implementation of exercise scenarios.
3.6 evaluators Personnel who assess the implementation of the exercise.
3.7 emergency plan It describes the work objectives, policies, and response philosophy of emergency response, as well as the organizations and functions for conducting a systematic, coordinated, and effective response.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.
Editions of GB/T 17680.12
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 17680.12-2025 | Criteria for emergency preparedness and response for nuclear power plants - Part 12: Planning, preparation, conduct and evaluation of nuclear emergency exercises | current edition | Current |
| GB/T 17680.12-2008 | Criteria for emergency preparedness and response for nuclear power plants - Part 12: Planning, preparation, conduct and evaluation of nuclear emergency exercises | previous edition | Superseded |
This page sells the current edition, GB/T 17680.12-2025. Earlier editions are listed for reference only.
How to Buy GB/T 17680.12-2025
- 1Add to cart. Click the "Buy GB/T 17680.12-2025" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17680.1-2008 — Criteria for emergency planning and preparedness for nuclear power plants - Part 1: The dividing of emergency planning zone
GB/T 17680.10-2003 — Criteria for emergency planning and preparedness for nuclear power plants--Criteria for emergency radiological field monitoring, sampling and analysis conducted by nuclear power plant operating organizations
GB/T 17680.11-2025 — Criteria for emergency preparedness and response for nuclear power plants — Part 11: Off-site radiological assessment for emergency response
Secure payment via Stripe
Payments accepted
GB/T 17680.12-2025
$350.00