Valid

GB/T 17215.421-2008Electricity metering equipment (a.c.) -- Tariff and load control -- Part 21: Particular requirements for time switches (English PDF)

交流测量-费率和负荷控制 第21部分:时间开关的特殊要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for GB/T 17215.421-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

August 6, 2008

Implementation date

March 1, 2009

Scope

GB/T 17215.421-2008 is the English-translated version of 交流测量-费率和负荷控制 第21部分:时间开关的特殊要求.

GB/T 17215.421-2008 — GB/T 17215 in the provisions of this part of the latest special type tests made for indoor use and has a working time of the switch to reserve begging.

Time switches commonly used in the electric power load control, maximum demand means multi-rate boarding and energy metering equipment.

Switches maintain real time, it can save the date, but also be able to handle leap years, when it also supports daylight saving time, that is to say, according to the relevant rules, it can modify the local time and GMT offset.

Time switch also has synchronization, switching time of the switch is also stored procedure table, which You can time period, week, or month in the specified date.

Time switch according to the time table and stored procedures to control the output unit. This part of the internal structure of the time switch is not required.

When the time switch function and multi-function meter function together, the relevant part of this section still apply. This section includes mechanical time having an analog dial or electronic digital display switch. --- Synchronous time switches; --- Crystal-controlled time switch.

This section does not include receiver testing and conformance testing, but receives the test given as examples in Appendix A. Reliability requirements with reference to IEC 62059.

This part of IEC 62052-21 when used simultaneously, this part of the terms better than IEC 62052-21.

Found what you need?

Document preview — GB/T 17215.421-2008

National Standard of the People's Republic of China

ICS
17.220.20
Classification
N 22
Replacing
GB/T 9092-1998

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 5 Mechanical requirements and tests
  • 5.1 Dial

Foreword

This section is equivalent to using the IEC 62054-21 "AC measurements tariff and load control - Part 21. Particular requirements for time switches" 2004 edition. "This part of the preparation of the structure and format is consistent with IEC 62054-21.

This Part replaces GB/T 9092-1998 "tariff and load control time switch." this part of GB/T 9092-1998 The main differences are as follows.

--- Terminology and definitions, electrical requirements, mechanical requirements, weather conditions, electromagnetic field immunity test DC, AC electromagnetic field immunity Test, test conditions and type tests, radio interference suppression requirements of a direct reference to IEC 62052-21;

--- This section increases the timing accuracy testing, electromagnetic field immunity test and fast transient tests done specifically described.

Since the implementation of this section, the original national standard GB/T 9092-1998 repealed simultaneously.

Appendix A of this section is an informative annex.

This part is proposed by China Machinery Industry Federation.

This part of the National Electrical Instrument Standardization Technical Committee (SAC/TC104) centralized.

This section is drafted. Harbin Institute of Electrical Instrument.

1 Scope

GB/T 17215 in the provisions of this part of the latest special type tests made for indoor use and has a working time of the switch to reserve begging. Time switches commonly used in the electric power load control, maximum demand means multi-rate boarding and energy metering equipment.

Switches maintain real time, it can save the date, but also be able to handle leap years, when it also supports daylight saving time, that is to say, according to the relevant rules, it can modify the local time and GMT offset. Time switch also has synchronization, switching time of the switch is also stored procedure table, which You can time period, week, or month in the specified date. Time switch according to the time table and stored procedures to control the output unit.

This part of the internal structure of the time switch is not required.

When the time switch function and multi-function meter function together, the relevant part of this section still apply.

This section includes mechanical time having an analog dial or electronic digital display switch.

--- Synchronous time switches;

--- Crystal-controlled time switch.

This section does not include receiver testing and conformance testing, but receives the test given as examples in Appendix A.

Reliability requirements with reference to IEC 62059.

This part of IEC 62052-21 when used simultaneously, this part of the terms better than IEC 62052-21.

2 Normative references

The following documents contain provisions which, through reference GB/T 17215 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

IEC 62052-21:2004 AC electronic power meter General requirements, tests and test conditions - Part 21. tariff and load control Claim

3 Terms and Definitions

IEC 62052-21 The definitions apply to this section.

Standard electrical values \u200b\u200b4 Value given in IEC 62052-21 apply to this section.

5 Mechanical requirements and tests

Requirements given in IEC 62052-21 and tests apply to this section.

5.1 Dial

For the time has analog mechanical dial switch.

--- Dial rotational direction by an arrow mark;

--- Hour dial (if any) should be able to read the minutes;

GB/T 17215.421-2008/IEC 62054-21:2004

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 17215.421-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 17215.421-2008

$115.00