Scope
GB/T 16895.33-2021 (Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services) is available as an English-translated PDF.
GB/T 16895.33-2021 — This document specifies the general requirements for the selection and installation of power supply systems for safety facilities and the power supply for safety facilities. This document does not apply to backup power supply systems. This document also does not apply to devices in hazardous locations (BE3), and its requirements are in IEC 60079-
Document preview — GB/T 16895.33-2021
National Standard of the People's Republic of China
- Classification
- P 63
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- 560.1 Scope1
- 560.2 Normative references1
- 560.3 Terms and Definitions2
- 560.4 Classification3
- 560.5 General4
- 560.6 Power Supply for Safety Facilities4
- 560.7 Electrical circuits of safety facilities5
- 560.8 Wiring system6
- 560.9 Emergency lighting applications6
- 560.10 Fire protection applications/equipment7
- Appendix A (Informative) Emergency Lighting Guide8
- Appendix B (Informative) Guide for Fire Fighting Equipment9
- Appendix C (informative) List of notes for each country10
- Appendix D (informative) Fire switch11
- Appendix E (informative) Examples of installation methods of safety facilities with cable management system12
- Appendix F (Informative) Wiring System13
- F.1 Environmental test temperature rise13
- F.2 Operation duration of safety facilities13
- F.3 Expected resistance of feeder conductor13
- F.4 Electric shock protection when measures to reduce contact voltage fail14
- F.5 Conductor resistance during fire14
- F.6 High temperature effects14
- F.7 Feeder circuit14
- Appendix G (Informative) Guidelines for Suitable Locations of Power Sources for Safety Facilities15
- G.1 Recommendations for the proper location of power sources for safety facilities15
- G.2 Fire conditions15
- Reference16
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"
Drafting.
GB/T 16895 "Low-Voltage Electrical Installations" is divided into 5 parts, and each part is divided into multiple sub-parts.
---Part 1.Basic principles, general characteristics assessment and definitions;
---Part 4.Security Protection;
---Part 5.Selection and installation of electrical equipment;
---Part 6.Inspection;
---Part 7.Requirements for special devices or places.
This document is part 5-56 of GB/T 16895 "Low-Voltage Electrical Installations". Part 5 of GB/T 16895 has published the following
part.
--- Part 5-51 of electrical installations of buildings. general rules for the selection and installation of electrical equipment;
--- Part 5-52 of low-voltage electrical installations. selection of electrical equipment and installation of wiring systems;
--- Building Electrical Installations Part 5-53.Selection and Installation of Electrical Equipment Isolation, Switching and Control Equipment Section 534.Over
Voltage protection appliances;
--- Part 5-54 of low-voltage electrical installations. selection and installation of electrical equipment, grounding configuration, protective conductor;
--- Part 5-55 of low-voltage electrical installations. selection of electrical equipment and installation of other equipment;
--- Low-voltage electrical installations Part 5-56.Selection of electrical equipment and installation safety facilities.
This document replaces GB/T 16895.33-2017 "Low-voltage electrical installations Part 5-56.Selection and installation safety of electrical equipment
Facilities'', compared with GB/T 16895.33-2017, in addition to structural adjustments and editorial changes, the main technical changes are as follows.
---The normative reference documents, terms and definitions have been changed (see 560.2, 560.3, 560.2, 560.3 of the.2017 edition);
---In the electrical circuit of safety facilities, the regulations on the isolation of safety circuit cables have been deleted (see 560.7.7 of the.2017 edition);
---In the electrical circuit of safety facilities, the requirement to maintain power supply in the event of a fire has been added (see 560.7.12), and the circuit of safety facilities should not be
RCDs or AFDDs protection requirements (see 560.7.13);
---In the "wiring system" chapter, the provision of conductor cross-sectional area (see 560.8.4), the wiring system of safety facilities and other equipment has been added
Provisions for isolation (see 560.8.5);
---In emergency lighting applications, requirements have been added to prevent any control system from negatively affecting the emergency lighting system (see 560.9.9),
Regulations for preventing the discharge of energy storage power supplies for safety facilities (see 560.9.16), regulations for neutral conductors (see 560.9.17); safety devices have been deleted
The control and bus systems of lighting installations should be independently specified (see 560.9.8 in the.2017 edition), and for the part of the power supply used in the building
Regulations for monitoring and control (see 560.9.11 in the.2017 edition);
---Added informative Appendix D fire switch;
---Informative Appendix E contains examples of installation methods for safety facilities of the cable laying management system;
---Added informative appendix F wiring system;
---Informative Appendix G Guidelines for suitable installation locations for power supplies for safety facilities have been added.
The translation method used in this document is equivalent to IEC 60364-5-56.2018 ``Low-voltage electrical installations Part 5-56.Selection of electrical equipment
And install safety facilities."
The Chinese documents that have a consistent correspondence with the international documents cited in this document are as follows.
---GB/T 2820.12-2002 AC generator sets driven by reciprocating internal combustion engines Part 12.Emergency to safety devices
Power supply (ISO 8528-12.1997, MOD);
---GB 7000.2-2008 Luminaires Part 2-22.Special requirements emergency lighting luminaires (IEC 60598-2-22..2002,
IDT);
---GB/T 7260.1-2008 Uninterruptible power supply equipment Part 1-1.General rules for UPS used in areas where operators reach
Safety requirements (IEC 62040-1-1.2002, MOD);
---GB/T 7260.2-2009 Uninterruptible Power Supply (UPS) Part 2.Electromagnetic Compatibility (EMC) Requirements (IEC 62040-
2.2005, IDT);
---GB/T 7260.3-2003 Uninterruptible power supply equipment (UPS) Part 3.Methods and test requirements for determining performance
(IEC 62040-3.1999,MOD);
---GB/T 13033.1-2007 Mineral insulated cables and terminals with rated voltages of 750V and below Part 1.Cables
(IEC 60702-1.2002, IDT);
---GB/T 13033.2-2007 Mineral insulated cables and terminals with rated voltages of 750V and below Part 2.Terminals
(IEC 60702-2.2002, IDT);
---GB/T 16895.6-2014 Low-voltage electrical installations Part 5-52.Selection of electrical equipment and installation of wiring systems
(IEC 60364-5-52.2009, IDT);
---GB/T 18380.12-2008 The burning test of electric cables and optical cables under flame conditions Part 12.Electricity of a single insulated wire
Cable flame vertical spread test 1kW pre-mixed flame test method (IEC 60332-1-2.2004, IDT);
---GB/T 19216 (all parts) Line integrity test of cables or optical cables under flame conditions [IEC 60331 (all parts)
Points), IDT].
The following editorial changes have been made to this document.
--- The content of the informative Appendix C "Notes List of Countries" has been deleted, which has nothing to do with my country's technical conditions.
Introduction
GB/T 16895 (all parts) on the safety protection of low-voltage electrical installations, electrical equipment selection and installation, inspection, and special installations
The safety requirements of homes or places play a guiding role. The published standard of GB/T 16895 consists of 5 parts.
---Part 1.Basic principles, general characteristics assessment and definitions. The purpose is to confirm the design, installation and inspection of low-voltage electrical installations.
Establish safety rules to avoid dangers and dangers to personnel, livestock and property that may occur in low-voltage electrical installations in reasonable use.
Damage and ensure the normal operation of electrical installations.
---Part 4.Safety protection. Contains 4-41, 4-42, 4-43, 4-44 sub-parts, the purpose is to establish the electric shock of low-voltage electrical devices
Basic requirements for protection, thermal effect protection, overcurrent protection, voltage disturbance and electromagnetic disturbance protection.
---Part 5.Selection and installation of electrical equipment. Contains 5-51, 5-52, 5-53, 5-54, 5-55, 5-56 sub-parts, the purpose is to follow
According to the basic requirements of safety protection, establish the functional requirements that meet the expected use of electrical devices and the general requirements for external influences.
Rules, as well as the establishment of wiring systems, isolation, on-off and control equipment, grounding arrangements and protective conductors, low-voltage power
The requirements for the selection and installation of electrical equipment such as auxiliary equipment, safety facilities and their power supply systems.
---Part 6.Inspection. The purpose is to establish requirements for preliminary inspection and periodic inspection of electrical installations.
---Part 7.Requirements for special devices or places. Contains 7-701, 7-702, 7-703, 7-704, 7-705, 7-706, 7-710,
Established, there is no relevant connection.
The above Part 1, Part 4, Part 5, and Part 6 are general requirements and regulations (general parts), which are also applicable under normal circumstances.
Used in Part 7 (cited without date), but in special installations and places, Part 7 proposes to supplement, modify or replace GB/T 16895
Some regulations and requirements of Part 1, Part 4, Part 5 and Part 6.
This part of GB/T 16895 includes the power supply, circuits, wiring and emergency lighting of safety facilities involved in the selection and installation of electrical devices
Protective measures.
The detailed rules are listed in the following six clauses.
---560.5 general rules;
---560.6 Safety facility power supply;
---560.7 safety facility loop;
---560.8 wiring system;
---560.9 Emergency lighting application;
---560.10 Fire protection application/equipment.
Low-voltage electrical installations part 5-56.
Selection of electrical equipment and installation of safety facilities
560.1 Scope
This document specifies the general requirements for the selection and installation of power supply systems for safety facilities and the power supply for safety facilities.
This document does not apply to backup power supply systems. This document also does not apply to devices in hazardous locations (BE3), and its requirements are in IEC 60079-
14 is given.
560.2 Normative references
The content of the following documents constitutes an indispensable clause of this document through normative references in the text. Among them, dated quotations
Only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
This document.
GB/T 16895.21-20111) Low-voltage electrical installations Part 4-41.Safety protection and electric shock protection (IEC 60364-4-41.
2005, IDT)
1) GB/T 16895.21-2011 will be completely replaced by GB/T 16895.21-2020 on July 1, 2021.
ISO 8528-12 AC generator sets driven by reciprocating internal combustion engines Part 12.Emergency power supply for safety devices (Recipro-
catinginternalcombustionenginedrivenalternatingcurrentgeneratingsets-Part 12.Emergency
powersupplytosafetyservices)
ISO 30061.2007 Emergency lighting (Emergencylighting)
IEC 60331 (all parts) Tests for electric cables or optical cables under flame conditions
underfireconditions-Circuitintegrity)
IEC 60332-1-2 Fire test of electric and optical cables under flame conditions Part 1-2.Vertical flame of a single insulated wire and cable
Spread test 1kW premixed flame test method (Testsonelectricandopticalfibrecablesunderfirecondi-
tions-Part 1-2.Testforverticalflamepropagationforasingleinsulatedwireorcable-Procedurefor
1kWpre-mixedflame)
IEC 60364-5-52 Low-voltage electrical installations Part 5-52.Selection and installation of electrical equipment wiring system (Low-voltage
electricalinstalations-Part 5-52.Selectionanderectionequipment-Wiringsystems)
IEC 60598-2-22 Luminaires Part 2-22.Special Requirements Emergency Lighting Luminaires (Luminaires-Part 2-22.Particular
requiremengts-Luminairesforemergencylighting)
IEC 60702-1 Mineral insulated cables and terminals with rated voltages up to and including 750V. Part 1.Cables (Mineralinsulated
cablesandtheirterminationswitharatedvoltagenotexceeding750V-Part 1.Cables)
IEC 60702-2 Mineral insulated cables and terminals with rated voltages up to and including 750V. Part 2.Terminals (Mineralinsulated
cablesandtheirterminationswitharatedvoltagenotexceeding750V-Part 2.Terminations)
IEC 62040-1 Uninterruptible power supply equipment Part 1.Safety requirements [Uninterruptible power systems (UPS)-
Part 1.Safetyrequirements]
IEC 62040-2 Uninterruptible Power Supply (UPS) Part 2.Electromagnetic Compatibility (EMC) Requirements (Uninterruptible
powersystems(UPS)-Part 2.Electromagneticcompatibility(EMC)requirements]
IEC 62040-3 Uninterruptible Power Supply (UPS) Part 3.Methods and Test Requirements for Determining Performance [Uninterruptible
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 16895.21-2011 · IEC 60364 · GB/T 16895.21-2020 · ISO 8528 · ISO 30061.2007 · IEC 60331 · IEC 60332 · IEC 60598 · IEC 60702 · IEC 62040
How to Buy GB/T 16895.33-2021
- 1Add to cart. Click the "Buy GB/T 16895.33-2021" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16895.10-2021 — Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
GB/T 16895.13-2022 — Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
GB/T 16895.22-2022 — Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection for safety, isolation, switching, control and monitoring
Secure payment via Stripe
Payments accepted
GB/T 16895.33-2021
$335.00