Valid

GB/T 16484.9-2009Chemical analysis methods of rare earth chloride and light rare earth carbonate - Part 9: Determination of nickel oxide content - Flame atomic absorption spectrometry (English PDF)

氯化稀土、碳酸轻稀土化学分析方法 第9部分:氧化镍量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 16484.9-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 30, 2009

Implementation date

May 1, 2010

Scope

GB/T 16484.9-2009 is the English-translated version of 氯化稀土、碳酸轻稀土化学分析方法 第9部分:氧化镍量的测定 火焰原子吸收光谱法.

GB/T 16484.9-2009 is the Chinese standard "Chemical analysis methods of rare earth chloride and light rare earth carbonate - Part 9: Determination of nickel oxide content - Flame atomic absorption spectrometry".

Its scope clause reads: GB/T 16484 provisions of this part of the determination of earth chloride and light rare earth carbonate, nickel oxide content. This section applies to rare earth, light rare earth carbonate - Determination of the amount of nickel oxide chlorination.

Measurement range 0.0020% to 0.010%. Its clauses include principle of the method; reagents; instrument; sample.

Found what you need?

Document preview — GB/T 16484.9-2009

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 14
Replacing
GB/T 16484.9-1996

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 principle of the method
  • 3 Reagents
  • 4 Instrument
  • 5 Sample

1 Scope

GB/T 16484 provisions of this part of the determination of earth chloride and light rare earth carbonate, nickel oxide content.

This section applies to rare earth, light rare earth carbonate - Determination of the amount of nickel oxide chlorination. Measurement range 0.0020% to 0.010%.

2 principle of the method

Sample with nitric acid dissolved in dilute nitric acid medium with air - acetylene flame, using the standard addition method in the atomic absorption spectrometer wavelength

Nickel absorbance measured at 232.0nm, the calculation of the amount of nickel oxide in the sample.

3 Reagents

Nitrate 3.1 (rho1.42g/mL).

3.2

Hydrogen peroxide (30%).

3.3

nitric acid (1 + 1).

3.4 Nickel standard stock solution

Weigh 0.2500g of nickel [w1 (Ni) >=99.99%] in 250mL beaker, add 10mL of nitric acid (3.3), heated until completely dissolved, removed, cooled to room temperature, transferred to 250mL volumetric flask, dilute to the mark with water and mix. This solution

1mL containing 1mg nickel.

3.5 Nickel standard solution

Pipette 10.00mL Nickel standard stock solution (3.4) in 1000mL flask, add 50mL of nitric acid (3.1),

Diluted with water to volume, and mix. This solution 1mL containing 10µg nickel.

4 Instrument

Atomic absorption spectrometer, with a nickel hollow cathode lamp.

Under optimum conditions the instrument, those who can reach the following indicators can be used.

--- Characteristic concentration. in the measurement sample solution matrix consistent solution, characteristic concentration of nickel is not more than 0.080µg/mL.

--- Precision. measuring the absorbance of the standard solution 10 times the highest concentration, the absorbance of the standard deviation does not exceed an average of 1.0%; most

Low concentrations of the standard solution (not a zero standard solution) absorbance measured 10 times, and the standard deviation should not exceed the maximum average absorption solution

0.5% luminosity.

--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment

Ratio of not less than 0.7.

5 Sample

5.1 Preparation of rare earth chloride sample

A sample was crushed, quickly placed in a weighing bottle immediately weighed.

5.2 Preparation of light rare earth carbonate sample

weigh the sample immediately after the opening.

Step 6 Analysis

6.1 Sample

Weigh 2.50g sample (5), accurate to 0.0001g.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 16484.9

EditionTitleRevisionStatus
GB/T 16484.9-2009Chemical analysis methods of rare earth chloride and light rare earth carbonate - Part 9: Determination of nickel oxide content - Flame atomic absorption spectrometrycurrent editionCurrent
GB/T 16484.9-1996Chemical analysis methods of rare earth chloride and light rare earth carbonate - Part 9: Determination of nickel oxide content - Flame atomic absorption spectrometryprevious editionSuperseded

This page sells the current edition, GB/T 16484.9-2009. Earlier editions are listed for reference only.

How to Download GB/T 16484.9-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 16484.9-2009

$105.00