GB/T 15952-2010Electroacoustics -- Specifications for personal sound exposure meters (English PDF)
电声学 个人声暴露计规范
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for GB/T 15952-2010 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 1, 2010
Implementation date
May 1, 2011
Scope
GB/T 15952-2010 is the English-translated version of 电声学 个人声暴露计规范.
GB/T 15952-2010 — 1.1 standard provides a level of accuracy of the personal sound exposure meter electric, acoustic performance requirements, when A-weighted sound pressure level range is 80dB ~ 130dB, the nominal frequency range of 63Hz ~ 8kHz, this level of accuracy and compliance with GB/T 17181 requirements for Type 2 Points Sound Level Meter fairly.
1.2 This standard applies to the measurement of steady, intermittent, fluctuating, A-weighted sound or irregular pulse sound exposure instrument. Comply with this Standard Specification for instrument worn on the body measurement specified sound exposure.
Measurement of workplace sound exposure, according to GB/T 14366 and GB/T 21230 Determination of occupational noise exposure may be useful. 1.3 sound exposure in a given position, by instantaneous frequency-weighted sound pressure squared integrated over time, it included a sound pressure of both its duration Physical measure.
1.4 Instrument performance deviates from a predetermined tolerance level on behalf of a specific instrument performance design goals. Within a specified range of environmental conditions, requirements Within this standard tolerance of personal sound exposure meter work.
Found what you need?
Document preview — GB/T 15952-2010
National Standard of the People's Republic of China
- ICS
- 17.140.50
- Classification
- A 59
- Replacing
- GB/T 15952-1995
Issued by: Standardization Administration of China
Contents
- Introduction
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 3 General performance requirements
- 4 5 reference conditions
- 6 Absolute sound sensitivity
- 7 Frequency weighting
- Linear 8-steady-state signal response of
- Response nine pairs of short duration signal
- Response 10 pairs of unipolar pulses
- 11 Self-locking overload indicator
- Environmental sensitivity of 12 pairs of
- 13 7 Instrument Flag
- 14 User's Guide
- 15 Electrostatic and electromagnetic compatibility requirements and test procedures
- Appendix A (informative) sound exposure and the corresponding normalized 8h average sound level
- Annex B (informative) personal sound exposure meter test performance test recommendations
- Annex C (informative) emission limits
- Functional unit 1 personal sound exposure meter
Foreword
This standard is identical with IEC 61252:2002 "electro-acoustics personal sound exposure meter specifications" (in English). This standard references the following countries the corresponding standard home contents and IEC 61252:2002 "electro-acoustics personal sound exposure meter specifications" (English Version) Content equivalents.
a) GB/T 3238-1982 Acoustics volume level and a reference value (neqISO 1683. 1983);
b) GB/T 3240-1982 acoustical measurement commonly used frequency (neqISO 266. 1975);
c) GB/T 3785-1983 sound level meter Electricity, Sound Performance and Test Methods (neq IEC 60651. 1979);
Evaluation of hearing impairment d) GB/T 14366-1993 Acoustics measurements and noise occupational noise-induced (eqvISO 1999.1990).
For ease of use, this standard made the following editorial changes.
a) instead of as a decimal by decimal comma ",". ",";
b) use the "standard" instead of "this International Standard";
c) Remove the IEC 61252:2002 in the preface, in which the individuals concerned and the sound exposure meters and integrating sound level meter is the difference between the contents of cooperation and this standard the "Introduction";
d) Normative documents according to the introductory phrase of GB/T 1.1-2000 rewritten;
e) The IEC 61252. "Definitions" section of the 2002 merger of the two key words, according to GB/T 1.1-2000 requirements rewritten;
f) 15.1.2 "Before release of the amendments" is replaced by "Prior to this release." this standard replaces GB/T 15952-1995 "personal sound exposure meters." this standard and GB/T 15952-1995 compared to the main changes are as follows.
a) the standard name was changed to "electro-acoustics for personal sound exposure meters norms";
b) "Introduction" section of GB/T 1.1-2000 requirements rewritten;
c) Remove the "IEC foreword";
d) "Introduction," added the former "IEC foreword" in relation to personal sound exposure meters and integrating sound level meter difference;
e) normative reference list file, add about six electromagnetic compatibility standard and GB/T 21230-2007 (ISO 9612:1997, IDT) and other documents;
f) increased "(personal sound exposure meter) reference bearing" terms and definitions;
g) Chapter 14 of u) item from the 1995 edition of the u), v) the content of the two merger;
h) In Chapter 14, "User's Guide," added the first w) to cc);
i) an increase of Chapter 15, "electrostatic and electromagnetic compatibility requirements and test procedures";
j) Added Appendix C "emission limits." this standard Annex A, Annex B and Annex C is informative appendix.
The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
This standard by the National Standardization Technical Committee electro-acoustics (SAC/TC23) centralized.
This standard was drafted. Hengyang Heng Instrument Electric Co., Ltd., China Institute of Metrology, red acoustic equipment factory Jiaxing factory, measurement Shenzhen Quality Inspection Institute.
Introduction
The intent of this standard, personal sound exposure meter is used to measure sound exposure, the instantaneous A-weighted sound pressure frequency square time integral. Its work as is the principle according to GB/T 17181 measured sound exposure level is based, that is, "and other energy exchange rate", the integration time constant sound level doubles (Or halved) will sound exposure doubled (or halved). Similarly, the integration time constant of the input sound level increases (or decreases) 3dB, the sound exposure Doubled (or halved).
Noise dosimeter is usually designed to indicate the percentage of statutory limit noise dose. Limit its definition of national regulations vary, and will change. In order to facilitate international comparison with the conventional recording sound exposure value represented by this standard specifies a quadratic Pa hour indication sound storm Lu instruments. As long as the manufacturer specified will be shown value is converted to quadratic Pa hour method, it allows outside Pa hours quadratic Other Unit indication sound exposure, for example, display fraction or percentage of the "dose" --- the provisions to sound quadratic Pa units of hours of exposure.
Personal sound exposure meter main application is to measure human exposure to sound near the head, for example, according to GB/T 14366 and other standards to evaluate possible hearing Power loss. Personal sound exposure meter microphone can be worn on the shoulder, collar, or other parts of your ear. For a number of specific cases, for example, in the factory, the incident angle of the sound will be great changes during the working day, the sound of the instrument worn on the body indicated may be exposed and personnel Measurements at different time of absence. When the sound when the body is not present estimates of exposure, it should consider wearing affect the body's personal sound exposure meter.
The standard for personal sound exposure meter standard and GB/T 17181-1997 comparable specification for integrating sound level meter in a practical range Consistent. Compared with the 1997 release of GB/T 17181 in the specification, there are four main differences.
a) measures and displays sound exposure instead of the equivalent continuous sound pressure level or frequency weighted sound exposure level;
b) the accuracy of short duration signal points and the square with the provisions of sound exposure duration 1ms ~ 10ms of constant amplitude of 4kHz Repeat measurement burst tone sequence, rather than the measurement of duration ranging from single 4kHz horn tone bursts of 1ms ~ 1s in response, each of the burst tone is accompanied by its own continuous-phase, low 4kHz background signal;
c) personal sound exposure meter specifications include positive and negative unipolar acoustic impulse response difference between the exposure limit values are shown;
d) does not require the wearing of the human body sound exposure meter used microphone directivity requirements.
Electro-acoustics personal sound exposure meters Specification
1 Scope
1.1 standard provides a level of accuracy of the personal sound exposure meter electric, acoustic performance requirements, when A-weighted sound pressure level range is 80dB ~ 130dB, the nominal frequency range of 63Hz ~ 8kHz, this level of accuracy and compliance with GB/T 17181 requirements for Type 2 Points Sound Level Meter fairly.
1.2 This standard applies to the measurement of steady, intermittent, fluctuating, A-weighted sound or irregular pulse sound exposure instrument. Comply with this Standard Specification for instrument worn on the body measurement specified sound exposure. Measurement of workplace sound exposure, according to GB/T 14366 and GB/T 21230 Determination of occupational noise exposure may be useful.
1.3 sound exposure in a given position, by instantaneous frequency-weighted sound pressure squared integrated over time, it included a sound pressure of both its duration Physical measure.
1.4 Instrument performance deviates from a predetermined tolerance level on behalf of a specific instrument performance design goals. Within a specified range of environmental conditions, requirements Within this standard tolerance of personal sound exposure meter work.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 3238-1982 Acoustics volume level and a reference value (neqISO 1683. 1983) GB/T 3240-1982 acoustical measurement commonly used frequency (neqISO 266. 1975) GB/T 3785-1983 sound level meter Electricity, Sound Performance and Test Methods (neq IEC 60651. 1979) GB radio disturbance characteristics - Limits and methods of measurement 9254-2008 information technology equipment (CISPR22.2006, IDT) GB/T 14366-1993 hearing impairment evaluation of occupational noise and acoustic noise caused by (eqvISO 1999.1990) GB/T 15173-1994 acoustic calibrator (eqvIEC 60942. 1988) GB/T 17181-1997 integrated average sound level (idtIEC 60804. 1985) GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2:2001, IDT) GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test (IEC 61000-4-3:2002, IDT) GB/T 17799.1-1999 Electromagnetic compatibility - Generic standards for residential, commercial and light industrial environment - Immunity (IdtIEC 61000-6-1.1997) GB/T 17799.2-2003 Electromagnetic compatibility - Generic standards - Immunity for industrial environments (IEC 61000-6-2:1999, IDT) GB/T 17799.3-2001 Electromagnetic compatibility - Generic standards for residential, commercial and light industrial environments Emission standard (IdtCISPR61000-6-3.1996) GB/T 21230-2007 Acoustics working environment measurement and evaluation guide of the noise exposure (ISO 9612:1997, IDT) IEC 60050 (801). Enhanced Edition 1984 International Electrotechnical Vocabulary Chapter 801, acoustics and electro-acoustics IEC 60801-2. 1984 Industrial process measurement and control equipment Electromagnetic compatibility - Part 2. Electrostatic discharge requirements IEC 60801-3. 1984 Electromagnetic industrial process measurement and control equipment compatibility - Part 3. Radio frequency electromagnetic field requirements
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 3785-1983Electroacoustics - Sound level meters - Part 1: Specifications
- GB/T 14366-1993Acoustics -- Estimation of noise-induced hearing loss
- GB/T 15173-1994Electroacoustics - Sound calibrators
- GB/T 17626.2-2006Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
- GB/T 17626.3-2006Electromagnetic compatibility - Testing and measurement techniques - Part 3: Radiated, radio-frequency, electromagnetic field immunity test
- GB/T 17799.1-1999Electromagnetic compatibility -- Generic standards -- Immunity for residential, commercial and light-industrial environments
GB/T 3238-1982 · GB/T 3240-1982 · IEC 60651 · GB/T 17181-1997 · IEC 61000 · GB/T 17799.3-2001 · GB/T 21230-2007 · ISO 9612 · IEC 60050 · IEC 60801
How to Download GB/T 15952-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 3785-1983 — Electroacoustics - Sound level meters - Part 1: Specifications
GB/T 18088-2026 — Sampling for entry and exit animal quarantine
GB/T 47983-2026 — Technical requirements for on-board energy consumption monitoring of passenger cars
Secure payment via Stripe
Payments accepted
GB/T 15952-2010
$295.00